http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
노학재,봉춘근,봉하경,김용구,조명행,김상화,김대성,Noh, Hakjae,Bong, Choonkeun,Bong, Hakyung,Kim, Yonggu,Cho, Myunghaing,Kim, Sanghwa,Kim, Daesung 한국입자에어로졸학회 2016 Particle and Aerosol Research Vol.12 No.1
In this work, we evaluated the characteristics of flow field and uniformity of the nose-only exposure chambers for the inhalation toxicity test. Computational fluid dynamics (CFD) modeling was carried out to demonstrate uniformity of the nose-only exposure chambers. Because it is very important in the inhalation toxicity experiments that test materials are distributed uniformly to each holder of the chamber. The test was done with these 3 types of chamber with different form to develop inhalation toxicity evaluation system, easy-to-operate system among exposure chamber used for evaluating inhalation toxicity of environmental chemical mixtures. Through CFD interpretation, nose-only exposure chamber was made with the selection of the optimal conditions. For its evaluation, one type of fragrance was selected and measured particle size distribution of each port. The gene becoming luminous to green fluorescence was combined with GPT-SPE, a type of tGFP vector, to be inhaled to the mouse. Based on this, luminous intensity was checked. As a result, total particle number concentration of each port had average value of $3.17{\times}10^6{\sharp}/cm^3$ and range of the highest and lowest concentration value was approximately ${\pm}4.8%$. Autopsy of lung tissues of mouse showed that it had clearly better delivery of gene compared to the control group.
실시간 측정기를 이용한 주요 농업 지역에서의 미세먼지 농도 특성
신재용,오정은,봉하경,탁준영,김현태,이상열 한국대기환경학회 2021 한국대기환경학회 학술대회논문집 Vol.2021 No.10
농업지역에서 발생하는 미세먼지는 난방, 생물성 연소, 농업기계 작업과정에서 발생하는 1차 미세먼지와 비료 · 분뇨에서 발생하는 암모니아에 의한 2차 미세먼지 생성으로 구분된다. 본 연구에서는 농업특성(논, 밭)의 미세먼지 발생특성을 파악하기 위해 IoT 기반 광산란식 미세먼지 측정기를 이용하여 영농지역에서 측정 · 분석하였다. 측정데이터는 실시간으로 당사에서 운용 중인 서버로 전송하여 원격으로 모니터링이 가능하도록 구현하였다. 이러한 IoT 시스템은 영농지역에 설치된 측정기를 도시에 위치한 당사의 기술연구소에서 원격으로 관리하며, 측정기의 이상 발생 시, 즉각적으로 조치할 수 있도록 구현하였다. 설치된 측정기는 환경부성능인증 1등급(정확도 80% 이상) 장비를 사용하였으며, 베타선 측정기(BAM1020, MetOne, USA) 및 고성능 광산란장비(11-D, Grimm, Germany)와 측정데이터를 비교하며, 정확도를 검증하였다. 논과 밭 대표지점에서 약 1년간 연속측정된 데이터를 인근에 있는 도시대기측정망과 비교하여 분석하였다. 영농지역은 계절별로 평균 미세먼지농도가 도시 대기보다 낮은 수준으로 나타났으나, 최대 측정값은 높게 나타났다. 이는 영농 잔재물 소각, 농업기계 작업 등이 일시적으로 먼지 농도를 높인 것으로 보인다. 기존 방식보다 저렴한 광산란식 측정방식을 이용해 영농지역의 측정망을 구축하여 측정 해상도를 높임으로써, 영농지역에서의 미세먼지 발생특성을 파악할 수 있을 것으로 판단된다.
광산란 계측기의 미세먼지 측정 정확도 향상을 위한 수분제거 전처리 기술 개발
강두수,오정은,이상열,신희준,봉하경,최주현,김대성,Kang, Doo Soo,Oh, Jung Eun,Lee, Sang Yul,Shin, Hee Joon,Bong, Ha Kyung,Choi, Joohyun,Kim, Dae Seong 한국입자에어로졸학회 2018 Particle and Aerosol Research Vol.14 No.4
IIn this study, we have developed drying systems for reducing the error by humidity on measuring particulate matter (PM) in the ambient air with optical particle measuring instruments. Two types of drying systems were designed: drying systems using heating and dilution methods. In addition, 3 types of drying systems using a heating method were designed: Type A (1 hole), B (3 holes) and C (7 holes). After making them, the laboratory and field tests were carried out to evaluate the developed drying systems. As a result, it was shown that the PM concentrations obtained by PM monitoring devices with drying systems agree well with that of the reference devices. Therefore, it could be concluded that the drying systems can be applied to PM monitoring devices for real-time monitoring of the ambient aerosols.
광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가
강두수,오정은,이상열,신희준,봉하경,김대성,Kang, Doo Soo,Oh, Jung Eun,Lee, Sang Yul,Shin, Hee Joon,Bong, Ha Kyung,Kim, Dae Seong 한국입자에어로졸학회 2018 Particle and Aerosol Research Vol.14 No.4
In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.
김용구(Yong-Gu Kim),봉춘근(Choon-Keun Bong),이상열(Sang-Yul Lee),봉하경(Ha-Kyung Bong) 한국산학기술학회 2014 한국산학기술학회 학술대회 Vol.2014 No.2
본 연구에서는 흡입독성평가 시험시 시험동물인 mouse에 노출되도록 균일한 농도와 동일 유량이 정확하고 일정하고 빠르게 각 노출port에 도달되도록 멀티채널 노출챔버를 개발하기 위한 기초자료를 확립하기 위해 수행되었다. 기존의 문제점을 검토하여 노출챔버를 설계제작하고, 시험자의 편의성 및 시험결과의 안전성 및 신뢰성 확보를 위한 발생입자의 유량배분 및 균일 입경분포 특성 등의 성능평가를 수행한 결과로써 대체로 흡입독성평가에 적합함을 확인할 수 있었다.
황지훈(Ji-Hoon Hwang),김용구(Yong-Gu Kim),이상열(Sang-Yul Lee),김한나(Han-Nah Kim),김세진(Se-Jin Kim),봉하경(Ha-Kyung Bong),봉춘근(Choon-Keun Bong) 한국산학기술학회 2015 한국산학기술학회 학술대회 Vol.2015 No.1
본 연구에서는 악취센서의 출력값이 불안정한 온습도 조건을 가진 악취가스를 적정한 온습도로 전처리한 후, 센서출력값의 성능성능에 대한 평가를 파악하고자 수행하였다. 실험결과 전처리 전에는 불안정하던 악취센서의 출력값이 전처리 후에는 안정적인 것을 확인할 수 있었다. 따라서, 악취가스 센서로 측정시 저온 및 고습환경을 고려하여 보다 정확한 전처리 시스템을 개발한다면, 보다 정확한 악취 측정이 가능할 것으로 판단된다.