        주택형화재경보기 작동에 따른 피난안전해석

        최영상,전흥균,백열선 한국화재소방학회 2011 한국화재소방학회논문지 Vol.25 No.6

        This study was performed to analysis the influence of smoke alarm detector on evacuation safety in housing fire. The analysis was conducted by CFAST fire simulation program and building EXODUS evacuation program. The effects of the earlier response time on evacuation safety were investigated by using evacuation simulation program with several steps of different response time and smoke alarm activation time for 4 occupants. The smoke detecter was activated 37.1 second after fire. The first two mortuary were occurred for 170 seconds of response time at the end of living room near exit. But for the 37.1 seconds of response time 4 occupants evacuated safely. From this study, the fire alarm detector is more important for safety evacuation in housing fire. 야간의 주택화재는 피난개시의 지연으로 인명피해 위험이 높아지게 된다. 따라서 주택용화재경보기를 설치하여 조기에 화재경보를 해주어 피난개시시간을 단축시킬 때의 피난안전을 해석하였다. 주택을 연구의대상 건물로 하여 CFAST를 사용해서 화재특성과 화재경보기 작동시간을 분석하였고, 이를 building EXODUS의 위험인자로 사용하여 4인 가족에 대한 피난시뮬레이션을 하였다. 피난개시시간을 다르게 하였을 때 170초에 피난을 개시한 경우 최초 사망자가 발생하였으나 주택용화재경보기작동시간 37.1초를 피난개시시간으로 한 경우는 안전한 피난이 되었다. 해석결과 주택용화재경보기를 설치할 경우 주택화재로부터 인명과 재산피해를 줄이는데 효과가 있다고 판단하였다.

      • 화재규모에 따른 고시원의 화재안전해석

        백열선 ; 최영상 김천대학교 2009 김천대학교 논문집 Vol.30 No.-

        다중이용시설에서의 화재는 불특정다수가 이용하기 때문에 신속한 초기대응과 피난이 이루어지기 곤란하여 많은 재산과 인명피해가 발생하는 특징이 있다. 특히 여러번의 고시원 화재를 겪으면서 다중이용업소의 안전관리에 관한 특별법이 마련되어 시행되고 있으나 고시원시설은 신고의 의해 영업이 가능한 신종자유업종으로 분류되어 관리감독부서가 명확하지 않아 효율적인 안전관리가 어려운 현실이다. 대다수의 고시원은 통로가 좁고 불타기 쉬운 내장재를 사용함에 따라 화재연소속도가 빠르고 피난이 어려운 단점을 가지고 있다. 따라서 화재 종류와 규모에 따라 어떤 위험이 존재하는지에 대한 정확한 해석이 필요하다. 본 연구에서는 고시원방안에서 침대 메트릭스와 소파에 화재가 발생한 경우에 연기의 확산속도와 유독성 가스의 분포를 조사하여 어떤 위험이 발생하는지 CFAST 로 화재시물레이션을 수행하고 그 결과를 분석하였다. Since the public facilities are used by incidental many, it is difficult to react early and evacuate when fire breaks out. Due to these reasons, the fire causes many property damage and causalities in public facilities. Because there are many fire incidences in Gosiwon, the specialized law of safety that is specific for the public facilities has been made. However, Gosiwon is a new branch that is easily allowed to in business with a license or a permission from the government, and the execu-tive department is not clear that safety law is not really possible to enforce effi-ciently. Most of the Gosiwon's hallways are narrow, and they are made up of inflammable materials. The burning rate of the material is rapid, causing difficulty in evacuating. It is necessary to identify and analyze the risk and damage that can be caused by different types and sizes of fire. Therefore, in this study, we studied and analyzed the burning of mattress and furniture in Gosiwon rooms, the impact of smoke, heat and spreading of toxic gases with CFAST conflagration simulation.

      • 주택화재시 피난개시시간에 따른 피난안전해석

        백열선 ; 최영상 김천대학교 2010 김천대학교 논문집 Vol.31 No.-

        This study was performed to analysis evacuation safety in housing fire with different response time. The evacuation simulation has included the impact of smoke layer hight, heat and toxic gases by fire simulation program (CFAST). In this study, the effect of the response time has been investigated by using evacuation simulation program (building EXODUS). The evacuation simulation were conducted with five steps of response time for 4 occupants. As a results, the smoke layer hight was 1.7m from floor in the living room (compartment 3) 40 second after fire. For 150 seconds of response time and 170 second after fire, the first mortuary was occurred at the end of living room (compartment 3) near exit. Three mortuary were occurred 170 second after fire, they started from compartment 1 and 6 where are far from exit. From this study, earlier evacuation start is more important for safety in housing fire where is no fire alarm and automatic fire extinguishing system such as sprinkler.