http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
New Records of the Diatoms (Bacillariophyta) in the Brackish and Coastal Waters of Korea
박준상,윤석민,이상득,이준백,이진환 한국환경생물학회 2017 환경생물 : 환경생물학회지 Vol.35 No.3
A study on indigenous diatoms was carried out at 10 sites from May 2014 to December 2016 in marine and freshwater in Korea. Seventeen species of diatoms are new to Korea and they are divided into 3 classes, 4 subclasses, 10 orders, 14 families, and 16 genera. The nomenclatures,references, dimensions, specimens examined, local habitat, distribution in Korea, and photograph are reported here. Seventeen species found in marine, freshwater, and brackish water showed species-specific habitats.
박준상 한국가시화정보학회 2023 한국가시화정보학회지 Vol.21 No.2
In the present study, we propose new type of a spinning disk reactor(SDR) with high performance and very convenient structure to make a large scale equipment from lab-scale than the conventional one. A split-disk experimental equipment, based on new type of spinning disk reactor, has been developed to generate an energy to break a bulk of injected gas into smaller gas bubble. Several cases of an experimental observation make it to confirm that a bulk of injecting gas could be continuously break into smaller bubbles. It shows the feasibility to make a scale-up of SDR by using the characteristic of Taylor-Proudman column in rotating flow. A theoretical study on single phase liquid flow is given to predict a liquid induced shear stress, which make the present study to be self-containment.
Pulsed Nd:YAG 레이저로 유발된 백서 설점막 창상의 조직학적 변화-수술칼에 의해 형성된 창상과의 비교 실험
박준상,박미희,박봉수 대한안면통증구강내과학회 1997 Journal of Oral Medicine and Pain Vol.22 No.1
The Author examined the clinical and histological changes on the dorsal tongue mucosa of the adult rats after lasing by pulsed Nd:YAG laser and incising with scalpel. The dorsal tongue was lased through 320$\mu\textrm{m}$optic fiber moving 2.5mm/second to make linear incision 5mm. The five conditions of lasing were three application with 1.0W, 1.75W, 3.0W and 3.0W under saline cooling, and single application with 3.0W at 20Hz. With scalpel, linear incisions through the surface epithelium were performed to 5mm in length. After observing the clinical changes of the incised wounds, the animals were sacrified and the tissues were excised to make the tissue specimens. The stained microscopic tissue slide were observed histologically under the microscope. The following results were obtained : 1. While incision with scalpel causes severe bleeding, lasing does not cause bleeding. 2. In three applications with 1.75W and 20Hz, tissue ablation was limited to areas contacted with optic fiber. 3. In three applications with 3.0W and 20Hz, deep incised wound, extensive destruction of the adjacent epithelium and charring were observed. 4. In three applications with 3.0W and 20Hz under saline cooling, tissue ablation was limite to the superficial mucosa and charring was not observed. 5. In single application with 3.0W and 20Hz, the shape of the incised wound was similar to that of the scalpel incision.