척추고정용 형상기억합금 동적안정기기의 생체역학적 성능 평가
김윤혁(Y. H. Kim),박원만(W. M. Park),김경수(K. Kim),박형균(H. K. Park),주증우(J. W. Joo),박경우(K. W. Park) 한국정밀공학회 2006 한국정밀공학회 학술발표대회 논문집 Vol.2006 No.5월
In this study, a commercial fixation device, BioFlex, which was designed with shape memory alloy(SMA) for dynamic stabilization of spine was biomechanically evaluated. The finite element model of intact lumbar spine from L1 to S was developed using CT images. Also, four FE models of 2-level(L4-L5-S) and 3-level(L3-L4-L5-S) posteriori fixation using titanium(Ti) rod and BioFlex(SMA) rod. The rotations of bone segments in the intact model and four models were predicted. Although the rotations of the BioFlex fixation model were smaller than those of the intact model, they were relatively larger than those of Ti fixation. The present can be applied for not only evaluation of the stability of interbody fixator, but also development of new implant.
슬관절 재전치환술용 경골삽입물 형상이 접촉압력 분포에 미치는 영향
김윤혁(Y. H. Kim),구교민(K. M. Koo),권오수(O. S. Kwon) 한국정밀공학회 2006 한국정밀공학회 학술발표대회 논문집 Vol.2006 No.5월
In this study, the effect of stem-end design on contact pressure and stress distribution in revision TKR was investigated using finite element method. The finite element model of tibia, including the cortical bone, the cancellous bone and canal, was developed based on CT images. The stem models with various stem lengths, diameters and frictional coefficients, and press-fit effects were considered . The results showed that the longer stem length, the stronger press-fit, the bigger stem diameter, and the higher frictional coefficient increased both peak contact pressure and the highest Von-Mises stress values. We hypothesized that peak contact pressure and Von-Mises stress distribution around the stem, may be related to the stem end pain. The results of this study will be useful to design the stem endand reduce the end-of-stem pain in revision TKR.
외고정법을 이용한 컴퓨터이용 및 로봇지원 골절수술 및 골변형교 정술에 대한 연구
김윤혁(Y. H. Kim) 한국정밀공학회 2005 한국정밀공학회 학술발표대회 논문집 Vol.2005 No.10월
This paper presents a computer-aided simulation and robotic-assisted execution technology of external fixation method to achieve fracture reduction and deformity correction in long bones. Combining the kinematic analysis with a graphic model of the tibia and the fixator allowed 3D simulation and visualization of the adjustments required to reduce fracture or correct bone deformity as a pre-operative planning tool. The developed robot model provided accurate deformity correction with small residual deformity based on the results of the planning. By incorporating the robot model with image-guided system and computer-aided planning, the integrated system could be useful for computer-aided pre-operative planning and roboticassisted execution in fracture treatment and bone deformity surgery.
강선의 인장력과 추가 Half pin이 혼성외고정장치 시스템의 안정성에 미치는 영향
김윤혁(Y. H. Kim),이현근(H. K. Lee),박원만(W. M. Park),오종건(J. K. Oh) 한국정밀공학회 2004 한국정밀공학회 학술발표대회 논문집 Vol.2004 No.10월
It is clinically well known that pre-tension of wires increases the fracture stability in ring or hybrid external fixation. In some cases, additional half pin should be necessary to increase the stability when soft tissue impalement occurs during fixation. In this paper, the fracture stability of a hybrid external fixator system with different pre-tension effects and additional half-pins was analysed using FEM to investigate the effects of these pre-tension and half pin on the system stability quantitatively. 3-D finite element models of five different fixator frames were developed using by beam elements. In axial compression analysis, the fracture stiffness was increased maximally 62% as the pre-tension increased. In torsion analysis, in the other hand, there is little variations in the fracture stiffness. Additional half pin increased the system stiffness about 200 %. From the results, proper pre-tension and additional half pin would provide good methods to increase the fracture stability of the hybrid external fixator and provide more surgical options to minimize soft tissue damage at the fracture site.