http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
강성현(Seong-Hyeon Kang),김태형(Tae-Hyung Kim) 한국지반신소재학회 2014 한국토목섬유학회 학술발표회 Vol.2014 No.11
Settlement prediction has been conducted using Hyperbolic, Hoshino, and Monden methods, etc in the fields. These methods are only able to predict settlement after finishing the final filling stage. A new method is proposed to make up for such a weak point. This method was named as Kang"s method, which can be able to predict the settlement both the final filling stage and the staged filling from the initial filling stage in soft ground. To verify the applicability of this method, the measured settlement curve history was compared with the predicted one. The predicted settlement is well matched with the measured one. From the study, the Kang"s method can be possible to predict settlement during the staged filling with only the initial settlement data.
복부 CT 영상의 화질 개선을 위한 total variation 기반의 노이즈 제거 알고리즘 최적화
강성현(Seong-Hyeon Kang),박민지(Minji Park),이도화(Do Hwa Lee),최혜란(Hye Ran Choi),이영진(Youngjin Lee) 대한전자공학회 2021 대한전자공학회 학술대회 Vol.2021 No.6
본 연구에서는 복부 CT 영상의 화질을 개선하기 위해 total variation (TV) 기반의 노이즈 제거 알고리즘을 최적화하고자 하였다. 이를 위해 인체의 뼈와 조직을 모사할 수 있는 Female Adult meSH (FASH) 팬텀을 이용하여 Gaussian noise가 모델링 된 시뮬레이션기반의 복부 CT 영상을 획득하였다. 또한, TV 기반의 노이즈 제거 알고리즘을 모델링한 후 다양한 평활화 인자를 설정하여 획득한 복부 CT 영상에 적용한 후에 대한 화질 평가를 위해 coefficient of variation (COV) 및 contrast to noise ratio (CNR)을 평가하였다. 결과적으로 COV 및 CNR 모두 0.01부터 0.21의 평활화 인자를 설정하였을 때 급격한 개선도를 보였으며 0.21 이후의 평활화 인자에서는 거의 일정한 값을 유지하였다. 결론적으로, 복부 CT 영상으로부터 TV 기반의 노이즈 제거 알고리즘을 적용할 때 최적화된 평활화 인자를 적용하는 것이 중요함을 증명하였다.
실시간 설비데이터를 활용한 휴대폰 메탈 프레임 공정의 다변량 모니터링
강성현(Seong Hyeon Kang),김성범(Seoung Bum Kim) 대한산업공학회 2016 대한산업공학회지 Vol.42 No.6
In mobile industry, using a metal frame of devices is rapidly increased for thin and stylish designs. However, fabricating metal is one of the difficult processes because the sophisticated control of equipment is required during the whole machining time. In this study, we present an efficient multivariate monitoring procedure for the metal frame process in mobile device manufacturing. The effectiveness of the proposed procedure is demonstrated by real data from the mobile plant in one of the leading mobile companies in South Korea.
칼슘이온과 초기 pH가 TiCl<SUB>4</SUB> 응집제의 인 제거에 미치는 영향
강성현(Seong Hyeon Kang),강장현(Jang Hyeon Kang),김한결(Han Gyul Kim),정희훈(Hee Hoon Jeong),김종호(Jong Ho Kim),안종화(Johng-Hwa Ahn) 大韓環境工學會 2017 대한환경공학회지 Vol.39 No.3
본 연구에서는 TiCl4 (0.12-0.18 mM)를 이용하여 합성 폐수(2 mg P/L)내 인을 제거할 때, 칼슘이온(Ca<SUP>2+</SUP>) (0-0.55 mM) 이 인 제거에 미치는 영향을 알아보았다. TiCl4 0.12 mM일 때 초기 pH(4.0-10.0)에 따른 실험결과 pH 7에서 인 제거율이 95.1%로 가장 높았고, pH 8에서 인 제거율이 51.4%로 떨어졌다. TiCl4 0.12 mM에서 Ca<SUP>2+</SUP>농도 0 mM일 때 인 제거율은 55.6%, Ca<SUP>2+</SUP>농도 0.045 mM에서는 90.5%로 증가하였다. 반면에 TiCl4 0.15-0.18 mM에서는 Ca<SUP>2+</SUP>농도에 따른 인 제거율(96.5-99.5%)의 차이는 미미하였다. TiCl4 농도를 0.12 mM로 고정하고, 초기 pH 7.0-9.0, Ca<SUP>2+</SUP> 농도 0.00-0.18 mM 범위에서 반응표면분석법을 이용하여 분석한 결과, 실험 범위내에서 인 제거율 90%이상을 얻기 위해서는 Ca<SUP>2+</SUP> 농도는 pH 8.0에서 0.10 mM, pH 9.0에서 0.12 mM 이상이 필요하다. This study experimentally determined the effect of calcium ion (Ca<SUP>2+</SUP>) (0-0.55 mM) and intial pH (4.0-10.0) on phosphorus (P) removal in synthetic wastewater (2 mg P/L) using titanium tetrachloride (TiCl4) (0.12-0.18 mM). At TiCl4 concentration ([TiCl4]) = 0.12 mM, the P removal efficiency was the highest (95.1%) at pH 7 but the efficiency decreased to 51.4% at pH 8. The P removal efficiency was 55.6% at Ca<SUP>2+</SUP> concentration ([Ca<SUP>2+</SUP>]) = 0 mM but the efficiency increased to 90.5% at [Ca<SUP>2+</SUP>] = 0.045 mM at [TiCl4] = 0.12 mM. On the other hand, the P removal efficiency difference was not large (96.5-99.5%) with [Ca<SUP>2+</SUP>] at [TiCl4] = 0.15-0.18 mM. Within the design boundaries of 0.00≤[Ca<SUP>2+</SUP>]≤0.18 mM and 7.0≤initial pH≤9.0 at [TiCl4] = 0.12 mM, the 90% P removal efficiency could be achieved at [Ca<SUP>2+</SUP>]≥0.10 mM with pH 8.0 and [Ca<SUP>2+</SUP>]≥0.12 mM with pH 9.0.
3D프린터를 이용한 CT 선량측정 팬텀 제작 및 비교에 관한 연구
윤명성 ( Myeong-seong Yoon ),강성현 ( Seong-hyeon Kang ),홍순민 ( Soon-min Hong ),이영진 ( Youngjin Lee ),한동균 ( Dong-koon Han ) 한국방사선학회 2018 한국방사선학회 논문지 Vol.12 No.6
전산화 단층촬영 장치의 정 도관리 항목 중 하나인 환자 피폭선량 피폭 시험은 의료법 제38조 특수의료장비 설치 및 운영에 따라 1년마다 측정을 시행하고 기록을 보관해야 한다. 선량 측정을 위해 사용되고 있는 CT-Dose 팬텀은 정확한 선량 측정이 가능하지만 가격이 비싸다는 단점이 있다. 따라서 본 연구를 통해 기존의 CT-Dose 팬텀을 3D프린터로 유사하게 제작하여 기존의 팬텀과 비교 분석하고 유용성을 알아보았다. 기존의 CT-Dose팬텀과 동일한 팬텀을 제작하기위해 PLA 필라멘트를 이용하여 FFF 방식의 3D프린터를 이용하였으며, CTDIw 값을 산출하기 위해 팬텀의 주변부와 중앙부에 이온챔버를 삽입하여 각 10번씩 측정하였다. 측정결과 주변부는 CT-Dose팬텀 30.44 ± 0.31 mGy, 중앙부는 29.55 ± 0.34 mGy CTDIw값은 30.14 ± 0.30 mGy로 측정되었고, 3D프린터를 이용하여 제작된 팬텀은 주변부 30.59 ± 0.18 mGy, 중앙부 29.01 ± 0.04 mGy, CTDIw값은 30.06 ± 0.13 mGy로 측정되었다. SPSS 통계 프로그램의 Mann- Whiteney U-test를 사용하여 분석한 결과 중앙부의 결과 값은 통계적으로 유의한 차이가 있었지만 주변부와 CTDIw의 결과 값은 통계적으로 유의한 차이를 나타내지 않았다. 결론적으로, 3D프린터를 이용하여 제작된 팬텀으로 기존의 CT-Dose 팬텀과 유사한 선량측정 성능을 보였으며, 본 연구를 통해 3D프린터를 이용한 저비용의 팬텀 제작의 가능성을 확인할 수 있었다. Patient exposure dose exposure test, which is one of the items of accuracy control of Computed Tomography, conducts measurements every year based on the installation and operation of special medical equipment under Article 38 of the Medical Law , And keep records. The CT-Dose phantom used for dosimetry can accurately measure doses, but has the disadvantage of high price. Therefore, through this research, the existing CT - Dose phantom was similarly manufactured with a 3D printer and compared with the existing phantom to examine the usefulness. In order to produce the same phantom as the conventional CT-Dose phantom, a 3D printer of the FFF method is used by using a PLA filament, and in order to calculate the CTDIw value, Ion chambers were inserted into the central part and the central part, and measurements were made ten times each. Measurement results The CT-Dose phantom was measured at 30.44 ± 0.31 mGy in the periphery, 29.55 ± 0.34 mGy CTDIw value was measured at 30.14 ± 0.30 mGy in the center, and the phantom fabricated using the 3D printer was measured at the periphery 30.59 ± 0.18 mGy, the central part was 29.01 ± 0.04 mGy, and the CTDIw value was measured at 30.06 ± 0.13 mGy. Analysis using the Mann - Whiteney U-test of the SPSS statistical program showed that there was a statistically significant difference in the result values in the central part, but statistically significant differences were observed between the peripheral part and CTDIw results I did not show. In conclusion, even in the CT-Dose phantom made with a 3D printer, we showed dose measurement performance like existing CT-Dose phantom and confirmed the possibility of low-cost phantom production using 3D printer through this research did it.