http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
신휘범(Hwi Beom Shin),이정훈(Jung Hoon Lee),정세교(Se Kyo Chung) 전력전자학회 1997 전력전자학술대회 논문집 Vol.1997 No.-
The windup phenomenon appears and results in the performance degradation when the PI controller output is<br/> saturated A new anti-windup PI controller is proposed to improve the control performance of the variable~speed motor drives and it is experimentally applied to the speed control of a vector-controlled induction motor driven by a<br/> pulse width modulated(PWM) voltage source inverter (YSI). The integral state is separately controlled corresponding to whether the PI controller output is<br/> saturated or not. The experimental results show that the speed response has the much improved performances such as small overshoot and fast settling time over the conventional anti-windup technique. Although the operating speed command is changed, the similar control performance can be obtained by using the PI gains selected in the linear region
Analysis of Multi-Phase Interleaved Boost Converter in Discontinuous Inductor Current Mode
신휘범(Hwi-Beom Shin),장은승(Eun-Sung Jang),이현우(Hyun-Woo Lee) 전력전자학회 2005 전력전자학술대회 논문집 Vol.- No.-
This paper presents the steady-state characteristics of the multi-phase interleaved converters in discontinuous inductor current mode(DICM). The full-order averaged model is derived, and the conversion ratio and efficiency are presented.
신휘범(Hwi-Beom Shin),이순영(Soonyoung Lee) 대한전기학회 2010 전기학회논문지 Vol.59 No.11
The superheater in the thermal power plant makes the wet steam into the dry steam with high temperature and high pressure by using the boiler heat. The dry steam pressure rotates the turbine-generator system. The efficiency and life time of the boiler heavily depends on the steam temperature regulation. The steam temperature can be deviated from the reference by the MW demand of the power plant. It is therefore required that the PI(proportional-integral) controller should be robust against the disturbance such as the MW demand. In this paper, the PI controller with the integral state predictor is proposed and applied to regulate the steam temperature of the superheater, and it is compared with the conventional PI controller operated in the thermal power plant in view of control performance.
신휘범(Hwi-Beom Shin) 한국조명·전기설비학회 2011 조명·전기설비학회논문지 Vol.25 No.7
An attemperator is a part of the 4-stage superheater in the boiler system of the thermal power plant. The attemperator receives the over-heated steam and makes the steam with proper temperature by adjusting the control valve of the cold steam. In this paper, the attemperator is modeled considering physical point of view and the linearized model is derived for the control purpose. To overcome the integral windup phenomenon due to the opening limitation of the control valve, an anti-windup PI controller is proposed to the attemperator and compared with the PI controller operated in the thermal power plant in view of control performance.
불연속 전류모드에서의 다상 교호 승압컨버터의 특성 해석
신휘범(Hwi-Beom Shin),장은승(Eun-Sung Jang),정세교(Se-Kyo Chung),이현우(Hyun-Woo Lee) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
This paper presents the generalized and explicit expressions for evaluating the performance of the multi-phase interleaved boost converter in discontinuous inductor current mode. Furthermore, the generalized transfer functions of interest are presented and the dynamic characteristics are analyzed. The generalized analysis of converter performance is verified through the experimental and simulation results.
스누버 전류를 고려한 개선된 SVPWM 인버터를 이용한 상전류센서없는 전동기 구동
주형길(Hyeong Gil Joo),신휘범(Hwi Beom Shin),안희욱(Hee Wook Ahn),윤명중(Myung Joong Youn) 전력전자학회 1999 전력전자학술대회 논문집 Vol.1999 No.7
The single sensor technique reconstructing phase currents from the dc-link current without phase current sensors is proposed. When the duration of active vector is too short for the snubber current to reduce, the dc-link current including the snubber current gives large detection error The solution is presented by analyzing the snubber current and mollifying the switching sequences. This scheme is simple, requires only one sampling a period and has good results for detecting the phase currents
단일전류센서를 이용한 교류전동기 구동에서 전동기 상수동정과 그 오차
주형길(Hyeong-Gil Joo),신휘범(Hwi-Beom Shin),윤명중(Myung-Joong Youn) 전력전자학회 2000 전력전자학술대회 논문집 Vol.2000 No.11
An estimation scheme is used for solving two practical problems of the single current sensor technique. To improve the effect of parameter uncertainties, the method that identifies motor parameters for AC motor drive systems using the single current sensor technique is presented. And, the parameter identification error and its cause are examined. It gives good performances for identifying parameters. and reconstructing phase currents.