http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Observation of Multiorder Coherent Raman Scattering in Solid Hydrogen Film
Geon Joon LEE,K. Hara,K. Hakuta,K. Katsuragawa 한국물리학회 2004 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.45 No.1
We investigated the Raman coherence characteristics of a solid hydrogen lm deposited on a sapphire substrate held at 5.3 K. Using Raman coherence prepared with two single-frequency pulsed lasers, we generated the multiorder coherent Raman sidebands in solid hydrogen lm. The highorder Raman sidebands were obtained under strong pumping intensities ( 230 MW/cm2). The generated anti-Stokes(AS)-Raman sidebands extend from the ultraviolet (292 nm for the AS5 band) to the visible (565 nm for the AS1 band) region. The multiorder Raman sideband generation is found to be due to the parametric coupling of pump and coupling lasers. The frequency conversion eciency from pumping beams to the rst AS-Raman sideband shows a maximum (14 %) at a pumping intensity of 360 MW/cm2. From an experiment that makes the multimode probe beam beat with the prepared Raman coherence, we found that the prepared Raman coherence replicates the probe beam to its Raman sidebands.
Search for the H Dibaryon in (K-, K+) Reactions
Bahk,S. Y.,Chung,K. S,Chung,S. H.,Funahashi,H.,Hahn,C. H.,Hara,T.,Hirata,S.,Hoshino,K.,Ieiri,M.,Iijima,T.,Imai,K.,Ishigami,T.,Itow,Y.,Kazuno,M.,Kikuchi,K.,Kim,C. O.,Kim,D. C.,Kim,J. Y.,Kobayashi,M.,Ko 國立昌原大學校 基礎科學硏究所 1992 基礎科學硏究所論文集 Vol.3 No.-
We have studied(??) reactions from an emulsion target. The S--2H dibaryon has been searched for by the analysis of the ??? momentum spectrum together with emulsion data. No evidence of H production was observed in the mass range of 1.90-2.16 GeV/c². Upper limits for the production cross section of the H are (0.2-0.6)% of that for the quasifree ??? production at the 90% confidence level.
Nakayama, S.,Mauger, C.,Ahn, M.H.,Aoki, S.,Ashie, Y.,Bhang, H.,Boyd, S.,Casper, D.,Choi, J.H.,Fukuda, S.,Fukuda, Y.,Gran, R.,Hara, T.,Hasegawa, M.,Hasegawa, T.,Hayashi, K.,Hayato, Y.,Hill, J.,Ichikawa Elsevier 2005 Physics letters: B Vol.619 No.3
<P><B>Abstract</B></P><P>Neutral current single <SUP>π0</SUP> production induced by neutrinos with a mean energy of 1.3 GeV is measured using a 1000 ton water Cherenkov detector in the K2K long baseline neutrino experiment. The cross section for this process relative to the total charged current cross section is measured to be 0.064±0.001(stat.)±0.007(sys.). The momentum distribution of neutral current <SUP>π0</SUP>s from a water target is measured with high statistics for the first time.</P>
Prompt Gamma Rays Emitted from the Neutron Capture Reaction of ^(74)Ge
K. Y. Hara 한국물리학회 2011 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.59 No.23
The decay scheme of ^(75)Ge in the ^(74)Ge(n,γ) reaction has been studied. Multiple prompt gamma rays emitted from the ^(74)Ge(n_(cold),γ)^(75)Ge reaction were measured with a germanium gamma-ray spectrometer at the Japan Research Reactor (JRR-3) of JAEA. Many unknown γ-ray transitions, in addition to the known ones, were seen in the energy spectrum. 14 new levels and 35 new γ-ray transitions of ^(75)Ge are reported.
Beam Spot Imaging System Using a Fluorescent Screen for Carbon-ion Radiotherapy
K. Mizushima,E. Takeshita,T. Furukawa,Y. Hara,T. Shirai,K. Katagiri,K. Noda 한국물리학회 2013 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.63 No.7
A two-dimensional (2D) beam imaging system with a fluorescent intensifying screen and highspeedcharge-coupled device (CCD) camera was developed to observe the fluctuations of the beamposition and size. This system can perform imaging of the beam spot and the calculation of bothits position and size from the obtained image with a cycle-time of 20 ms. For quality assurance ofscanned carbon-ion therapy, we measured the stability of the unscanned-beam position and size byusing this system at the isocenter in a treatment room. We confirmed that the fluctuation rangesof its position and size were less than the tolerance for scanning irradiation.
Y. Hara,T. Furukawa,K. Mizushima,S. Sato,T. Shirai,K. Noda,E. Takeshita 한국물리학회 2013 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.63 No.7
A two-dimensional dosimetry system was developed for the quality assurance (QA) of therapeuticscanned ion beams at Heavy Ion Medical Accelerator in Chiba (HIMAC). This system consists of afluorescent screen and a charge-coupled device (CCD) camera. To evaluate the performance of thissystem, we carried out a few experiments concerning QA procedures. A verification of this systemwas also carried out by comparing the film dosimetry and the ionization chamber array. Also, weverified several types of corrections for errors, e.g., background and vignetting, that distort themeasurement results. As a result, we confirmed that this system could be used for QA proceduresof the therapeutic scanned ion beams.
Evidence of Weak Decay of Heavy Double Hypernuclei
Aoki, S.,Bahk, S. Y.,Chung, K. S.,Chung, S. H.,Funahashi, H.,Hahn, C. H.,Hara, T.,Hirata, S.,Hoshino, K.,Ieiri, M.,Iijima, T.,Imai, K.,Ishigami, T.,Itow, Y.,Kazuno, M.,Kikuchi, K.,Kim, C. O.,Kim, D. C 國立昌原大學校 基礎科學硏究所 1992 基礎科學硏究所論文集 Vol.3 No.-
We have studied 80 events of candidates for ??? capture star at rest in nuclear emulsion, where ??? hyperons are produced in (??????) reactions identified by a ?? spectrometer. The weak decay of heavy double hypernuclei is confirmed, studying the distribution of visible energy-release and the probability of emission of two fast protons, in comparison with those for single hypernuclei.