RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Study on the Energy Spectrum Response of a CdZnTe Detector

        Yuandong Li,Liangquan Ge,Kun Sun,Shangqing Sun,Guoqiang Zeng,Chengjun Tan 한국물리학회 2020 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.76 No.9

        In order to study the energy spectrum response of a CdZnTe detector, we firstly measured the temperature dependence and the bias dependence of the main characteristic parameters for both a quasi-hemispherical detector and a CAPtureTM plus detector. Secondly, we designed a low-noise readout circuit for the CdZnTe detector and measured the noise. Finally, we evaluated the energy spectrum response of the detector to different radioactive sources at different temperatures by connecting the detector to the readout circuit. The research showed that both detectors had low leakage current and junction capacitance, as well as good stability in temperature and bias; the quasi-hemispheric detector had a smaller leakage current and junction capacitance compared to the CAPtureTM plus detector; under zero input capacitor, the noise of the readout circuit was 612e, with the noise slope being 5.44e/pF; at room temperature(20 °C), the energy resolutions of the detector reached 3.84% and 1.36% for X-rays from 241Am (59.5 keV) and gamma-rays from 137Cs (662 keV), respectively; the signal-noise ratio of the output signal reached 31:1 with the rise time being 90 ns; at low temperature, the energy resolution reached 3.41% for the X-rays from 241Am (59.5 keV); the detector achieved an excellent spectrum response and was able to distinguish clearly the energy peaks of 152Eu and 226Ra.

      • KCI등재

        Study on the γ + X, γ + β, γ + α Coincidence Summing Effects of the Intrinsic Background Instrument Spectrum of a LaBr3(Ce) Scintillation Counter

        Sun Shangqing,Ge Liangquan,Li Yuandong,Hu Chuanhao 한국물리학회 2020 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.77 No.12

        The energy resolution of a LaBr3(Ce) scintillation counter can reach 2.7% (662 keV) at room temperature. As a radiation measuring device, it has remarkably good characteristics. However, the LaBr3(Ce) crystal has its own intrinsic radioactivity background, which mainly comes from 138La and from 227Ac and its daughters. 138La can emit β, γ and X-rays through β and γ decay; 227Ac and its daughters can emit α, β and γ-rays through α, β and γ decay. α, γ and X-ray energy are characteristic while β-ray energy is continuous. The energy of α, β and X-rays is mainly deposited in the crystal unless the α, β and X-rays at the edge of the crystal can escape from the crystal. Therefore, the α, β, γ and X-rays generated by the intrinsic radioactivity of the crystal are superimposed on the instrument spectrum, which makes the instrument spectrum more complicated and produces the coincidence summing effects of γ + X, γ + β and γ + α. In this research, the GEANT4.9.5 software package was used to simulate the spectra of α, β, γ and X-rays. On the basis of a combination of fitting decomposition and reconstruction, the simulation spectrum of the LaBr3(Ce) self-radioactive background was obtained accurately and was verified by using physical experiments.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼