RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Rigid-Plating and Cortico-Cancellous Allograft Are Effective for 3-Level Anterior Cervical Discectomy and Fusion: Radiographic and Clinical Outcomes

        Philip K. Louie,Andrew C. Sexton,Danel D. Bohl,Ehsan Tabaraee,Steven M. Presciutti,Benjamin C. Mayo,Justin C. Paul,Comron Saifi,Howard S. An 대한척추신경외과학회 2020 Neurospine Vol.17 No.1

        Objective: To determine the risk factors associated with radiographic changes and clinical outcomes following 3-level anterior cervical discectomy and fusion (ACDF) using rigidplate constructs and cortico-cancellous allograft. ACDF has demonstrated efficacy for treatment of multilevel degenerative cervical conditions, but current data exists in small heterogeneous forms. Methods: A retrospective review included 98 patients with primary 3-level ACDF surgery at one institution from 2008 to 2013 with minimum 1-year follow-up. Cervical sagittal vertical axis (SVA), segmental height, fusion, and lordosis radiographs were measured preoperatively and at 2 postoperative periods. Results: Rates of asymptomatic pseudarthroses and total reoperations were 18% and 4%, respectively. Results demonstrated immediate improvements in cervical lordosis (5.5°, p<0.01) and segmental height (5.0-mm increase, p<0.01) with little changes in the cervical SVA (3.2-mm increase, p<0.01). The segmental height decreased from immediate postoperative period to final follow-up (1.7-mm decrease, p<0.01). Older age was protective against radiolucent lines (p<0.05). Patient-reported outcomes significantly improved following surgery (p<0.01). Current smoking status and diagnosis of diabetes mellitus had no impact on radiographic or clinical outcomes. Risk factors were not identified for the 5 reoperations (4%). Conclusion: Three-level ACDF with rigid-plating and cortico-cancellous allograft is an effective procedure for degenerative diseases of the cervical spine without the application of additional adjuncts or combined anteriorposterior cervical surgeries. Significant improvements in cervical lordosis, segmental height, and segmental alignment can be achieved with little change in cervical SVA and a low rate of reoperations over short-term follow-up. Similarly, patient-reported outcomes show significant improvements.

      • KCI등재

        Randomized comparison of popliteal-sciatic perineural catheter tip migration and dislocation in a cadaver model using two catheter designs

        Lauren Steffel,Steven K. Howard,Edward R. Mariano,Lindsay Borg,Jody C. Leng,T. Edward Kim 대한마취통증의학회 2017 Korean Journal of Anesthesiology Vol.70 No.1

        Background: New catheter-over-needle (CON) technology for continuous peripheral nerve blockade has emerged, but its effect on the risk of perineural catheter tip dislocation is unknown. Less flexible catheters may be more likely to migrate away from the nerve with simulated patient movement. In the present study, we evaluated catheter tip migration between CON catheters and traditional catheter-through-needle (CTN) catheters during ultrasound-guided short-axis in-plane (SAX-IP) insertion. Methods: We evaluated the migration of popliteal-sciatic catheters in a prone, unembalmed male cadaver. Thirty catheter placement trials were divided randomly into two groups based on the catheter type: CON or CTN. A single anesthesiology resident placed the catheters by SAX-IP insertion, and the catheters were then examined by ultrasound before and after ipsilateral knee range of motion (ROM) exercises (0o–130o flexion). A blinded expert regional anesthesiologist performed caliper measurements on the ultrasound images before and after the ROM exercises. The primary outcome was the change in distance from the catheter tip to the center of the nerve (cm) between before and after the ROM exercises. Results: The change in the tip-to-nerve distance (median [10th–90th percentile]) was 0.06 (−0.16 to 0.23) cm for the CTN catheter and 0.00 (−0.12 to 0.69) for the CON catheter (P = 0.663). However, there was a statistically significant increase in dislocation out of the nerve compartment for the CON catheter (4/15; 0/15 for CTN) (P = 0.043). Conclusions: Although the use of different catheter designs had no effect on the change in the measured migration distance of popliteal-sciatic catheters, 27% of the CON catheters were dislocated out of the nerve compartment. These results may influence the choice of catheter design when using SAX-IP perineural catheter insertion.

      • KCI등재

        A comparison of strength for two continuous peripheral nerve block catheter dressings

        Edward R. Mariano,Lindsay Borg,Steven K. Howard,T. Edward Kim,Lauren Steffel,Cynthia Shum 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.5

        Background: Despite the benefits of continuous peripheral nerve blocks, catheter dislodgment remains a major problem, especially in the ambulatory setting. However, catheter dressing techniques to prevent such dislodgment have not been studied rigorously. We designed this simulation study to test the strength of two commercially available catheter dressings. Methods: Using a cadaver model, we randomly assigned 20 trials to one of two dressing techniques applied to the lateral thigh: 1) clear adhesive dressing alone, or 2) clear adhesive dressing with an anchoring device. Using a digital luggage scale attached to a loop secured by the dressing, the same investigator applied steadily increasing force with a downward trajectory towards the floor until the dressing was removed or otherwise disrupted. Results: The weight, measured (median [10th–90th percentile]) at the time of dressing disruption or removal, was 1.5 kg (1.3–1.8 kg) with no anchoring device versus 4.9 kg (3.7–6.5 kg) when the dressing included an anchoring device (P < 0.001). Conclusions: Based on this simulation study, using an anchoring device may help prevent perineural catheter dislodgement and therefore premature disruption of continuous nerve block analgesia.

      • KCI등재

        Using eye tracking technology to compare the effectiveness of malignant hyperthermia cognitive aid design

        Roderick King,Jaber Hanhan,T. Kyle Harrison,Alex Kou,Steven K. Howard,Lindsay K. Borg,Cynthia Shum,Ankeet D. Udani,Edward R. Mariano 대한마취통증의학회 2018 Korean Journal of Anesthesiology Vol.71 No.4

        Background: Malignant hyperthermia is a rare but potentially fatal complication of anesthesia, and several different cognitive aids designed to facilitate a timely and accurate response to this crisis currently exist. Eye tracking technology can measure voluntary and involuntary eye movements, gaze fixation within an area of interest, and speed of visual response and has been used to a limited extent in anesthesiology. Methods: With eye tracking technology, we compared the accessibility of five malignant hyperthermia cognitive aids by collecting gaze data from twelve volunteer participants. Recordings were reviewed and annotated to measure the time required for participants to locate objects on the cognitive aid to provide an answer; cumulative time to answer was the primary outcome. Results: For the primary outcome, there were differences detected between cumulative time to answer survival curves (P < 0.001). Participants demonstrated the shortest cumulative time to answer when viewing the Society for Pediatric Anesthesia (SPA) cognitive aid compared to four other publicly available cognitive aids for malignant hyperthermia, and this outcome was not influenced by the anesthesiologists’ years of experience. Conclusions: This is the first study to utilize eye tracking technology in a comparative evaluation of cognitive aid design, and our experience suggests that there may be additional applications of eye tracking technology in healthcare and medical education. Potentially advantageous design features of the SPA cognitive aid include a single page, linear layout, and simple typescript with minimal use of single color blocking.

      • KCI등재

        Can bedside patient-reported numbness predict postoperative ambulation ability for total knee arthroplasty patients with nerve block catheters?

        Edward R. Mariano,Seshadri C. Mudumbai,Toni Ganaway,T. Edward Kim,Steven K. Howard,Nicholas J. Giori,Cynthia Shum 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.1

        Background: Adductor canal catheters offer advantages over femoral nerve catheters for knee replacement patients because they produce less quadriceps muscle weakness; however, applying adductor canal catheters in bedside clinical practice remains challenging. There is currently no patient-reported outcome that accurately predicts patients’ physical function after knee replacement. The present study evaluates the validity of a relatively new patient-reported outcome, i.e., a numbness score obtained using a numeric rating scale, and assesses its predictive value on postoperative ambulation. Methods: We conducted a retrospective cohort study pooling data from two previously-published clinical trials using identical research methodologies. Both studies recruited patients undergoing knee replacement; one studied adductor canal catheters while the other studied femoral nerve catheters. Our primary outcome was patient-reported numbness scores on postoperative day 1. We also examined postoperative day 1 ambulation distance and its association with postoperative numbness using linear regression, adjusting for age, body mass index, and physical status. Results: Data from 94 subjects were included (femoral subjects, n = 46; adductor canal subjects, n = 48). Adductor canal patients reported decreased numbness (median [10th–90th percentiles]) compared to femoral patients (0 [0–5] vs. 4 [0–10], P = 0.001). Adductor canal patients also ambulated seven times further on postoperative day 1 relative to femoral patients. There was a significant association between postoperative day 1 total ambulation distance and numbness (Beta = −2.6; 95% CI: −4.5, −0.8, P = 0.01) with R2 = 0.1. Conclusions: Adductor canal catheters facilitate improved early ambulation and produce less patient-reported numbness after knee replacement, but the correlation between these two variables is weak.

      • KCI등재

        Implementation of clinical practice changes by experienced anesthesiologists after simulationbased ultrasound-guided regional anesthesia training

        T. Edward Kim,Edward R. Mariano,Toni Ganaway,T. Kyle Harrison,Steven K. Howard,Cynthia Shum,Alex Kuo 대한마취통증의학회 2017 Korean Journal of Anesthesiology Vol.70 No.3

        Background: Anesthesiologists who have finished formal training and want to learn ultrasound-guided regional anesthesia (UGRA) commonly attend 1 day workshops. However, it is unclear whether participation actually changes clinical practice. We assessed change implementation after completion of a 1 day simulation-based UGRA workshop. Methods: Practicing anesthesiologists who participated in a 1 day UGRA course from January 2012 through May 2014 were surveyed. The course consisted of clinical observation of UGRA procedures, didactic lectures, ultrasound scanning, hands-on perineural catheter placement, and mannequin simulation. The primary outcome was the average number of UGRA blocks per month reported at follow-up versus baseline. Secondary outcomes included preference for ultrasound as the nerve localization technique, ratings of UGRA teaching methods, and obstacles to performing UGRA. Results: Survey data from 46 course participants (60% response rate) were included for analysis. Participants were (median [10th–90th percentile]) 50 (37–63) years old, had been in practice for 17 (5–30) years, and were surveyed 27 (10–34) months after their UGRA training. Participants reported performing 24 (4–90) blocks per month at follow-up compared to 10 (2–24) blocks at baseline (P < 0.001). Compared to baseline, more participants at follow-up preferred ultrasound for nerve localization. The major obstacle to implementing UGRA in clinical practice was time pressure. Conclusions: Participation in a 1 day simulation-based UGRA course may increase UGRA procedural volume by practicing anesthesiologists.

      • KCI등재

        An ultrasound-guided fascia iliaca catheter technique does not impair ambulatory ability within a clinical pathway for total hip arthroplasty

        Edward R. Mariano,Seshadri C. Mudumbai,T. Edward Kim,Steven K. Howard,Nicholas J. Giori,Steven Woolson,Toni Ganaway,Alex Kou,Robert King 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.4

        Background: Both neuraxial and peripheral regional analgesic techniques offer postoperative analgesia for total hip arthroplasty (THA) patients. While no single technique is preferred, quadriceps muscle weakness from peripheral nerve blocks may impede rehabilitation. We designed this study to compare postoperative ambulation outcome in THA patients who were treated with a new ultrasound-guided fascia iliaca catheter (FIC) technique or intrathecal morphine (ITM). Methods: We reviewed the electronic health records of a sequential series of primary unilateral THA patients who were part of a standardized clinical pathway; apart from differences in regional analgesic technique, all other aspects of the pathway were the same. Our primary outcome was total ambulation distance (meters) combined for postoperative days 1 and 2. Secondary outcomes included daily opioid consumption (morphine milligram equivalents) and analgesic-related side effects. We examined the association between the primary outcome and analgesic technique by performing crude and adjusted ordinary least-squares linear regression. A P value < 0.05 was considered statistically-significant. Results: The study analyzed the records of 179 patients (fascia iliaca, n = 106; intrathecal, n = 73). The primary outcome (total ambulation distance) did not differ between the groups (P = 0.08). Body mass index (BMI) was the only factor (β = −1.7 [95% CI −0.5 to −2.9], P < 0.01) associated with ambulation distance. Opioid consumption did not differ, while increased pruritus was seen in the intrathecal group (P < 0.01). Conclusions: BMI affects postoperative ambulation outcome after hip arthroplasty, whereas the type of regional analgesic technique used does not. An ultrasound-guided FIC technique offers similar analgesia with fewer side effects when compared with ITM.

      • KCI등재

        Virtual reality distraction decreases routine intravenous sedation and procedure-related pain during preoperative adductor canal catheter insertion: a retrospective study

        Pooja G. Pandya,Edward R. Mariano,T. Edward Kim,Steven K. Howard,Erica Stary,Jody C. Leng,Oluwatobi O. Hunter 대한마취통증의학회 2017 Korean Journal of Anesthesiology Vol.70 No.4

        Background: Virtual reality (VR) distraction is a nonpharmacological method to prevent acute pain that has not yet been thoroughly explored for anesthesiology. We present our experience using VR distraction to decrease routine intravenous sedation for patients undergoing preoperative perineural catheter insertion. Methods: This 1-month quality improvement project involved all elective unilateral primary total knee arthroplasty patients who received a preoperative adductor canal catheter. Clinical data were analyzed retrospectively. For the first half of the month, all patients received usual care; intravenous sedation was administered at the discretion of the regional anesthesiologist. For the second half of the month, patients were offered VR distraction with intravenous sedation upon request. The primary outcome was fentanyl dosage; other outcomes included midazolam dosage, procedure-related pain, procedural time, and blood pressure changes. Results: Seven patients received usual care and seven used VR. In the VR group, 1/7 received intravenous sedation versus 6/7 who received usual care (P = 0.029). The fentanyl dose was lower (median [10th–90th percentiles]) in the VR group (0 [0–20] μg) versus the non-VR group (50 [30–100] μg; P = 0.008). Midazolam use was lower in the VR group (0 [0–0] mg) than in the non-VR group (1 [0–1] mg; P = 0.024). Procedure-related pain was lower in the VR group (1 [1–4] NRS) versus the non-VR group (3 [2–6] NRS; P = 0.032). There was no difference in other outcomes. Conclusions: VR distraction may provide an effective nonpharmacological alternative to intravenous sedation for the ultrasound-guided placement of certain perineural catheters.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼