RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        A comparison of strength for two continuous peripheral nerve block catheter dressings

        Edward R. Mariano,Lindsay Borg,Steven K. Howard,T. Edward Kim,Lauren Steffel,Cynthia Shum 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.5

        Background: Despite the benefits of continuous peripheral nerve blocks, catheter dislodgment remains a major problem, especially in the ambulatory setting. However, catheter dressing techniques to prevent such dislodgment have not been studied rigorously. We designed this simulation study to test the strength of two commercially available catheter dressings. Methods: Using a cadaver model, we randomly assigned 20 trials to one of two dressing techniques applied to the lateral thigh: 1) clear adhesive dressing alone, or 2) clear adhesive dressing with an anchoring device. Using a digital luggage scale attached to a loop secured by the dressing, the same investigator applied steadily increasing force with a downward trajectory towards the floor until the dressing was removed or otherwise disrupted. Results: The weight, measured (median [10th–90th percentile]) at the time of dressing disruption or removal, was 1.5 kg (1.3–1.8 kg) with no anchoring device versus 4.9 kg (3.7–6.5 kg) when the dressing included an anchoring device (P < 0.001). Conclusions: Based on this simulation study, using an anchoring device may help prevent perineural catheter dislodgement and therefore premature disruption of continuous nerve block analgesia.

      • KCI등재

        Implementation of clinical practice changes by experienced anesthesiologists after simulationbased ultrasound-guided regional anesthesia training

        T. Edward Kim,Edward R. Mariano,Toni Ganaway,T. Kyle Harrison,Steven K. Howard,Cynthia Shum,Alex Kuo 대한마취통증의학회 2017 Korean Journal of Anesthesiology Vol.70 No.3

        Background: Anesthesiologists who have finished formal training and want to learn ultrasound-guided regional anesthesia (UGRA) commonly attend 1 day workshops. However, it is unclear whether participation actually changes clinical practice. We assessed change implementation after completion of a 1 day simulation-based UGRA workshop. Methods: Practicing anesthesiologists who participated in a 1 day UGRA course from January 2012 through May 2014 were surveyed. The course consisted of clinical observation of UGRA procedures, didactic lectures, ultrasound scanning, hands-on perineural catheter placement, and mannequin simulation. The primary outcome was the average number of UGRA blocks per month reported at follow-up versus baseline. Secondary outcomes included preference for ultrasound as the nerve localization technique, ratings of UGRA teaching methods, and obstacles to performing UGRA. Results: Survey data from 46 course participants (60% response rate) were included for analysis. Participants were (median [10th–90th percentile]) 50 (37–63) years old, had been in practice for 17 (5–30) years, and were surveyed 27 (10–34) months after their UGRA training. Participants reported performing 24 (4–90) blocks per month at follow-up compared to 10 (2–24) blocks at baseline (P < 0.001). Compared to baseline, more participants at follow-up preferred ultrasound for nerve localization. The major obstacle to implementing UGRA in clinical practice was time pressure. Conclusions: Participation in a 1 day simulation-based UGRA course may increase UGRA procedural volume by practicing anesthesiologists.

      • KCI등재

        Can bedside patient-reported numbness predict postoperative ambulation ability for total knee arthroplasty patients with nerve block catheters?

        Edward R. Mariano,Seshadri C. Mudumbai,Toni Ganaway,T. Edward Kim,Steven K. Howard,Nicholas J. Giori,Cynthia Shum 대한마취통증의학회 2016 Korean Journal of Anesthesiology Vol.69 No.1

        Background: Adductor canal catheters offer advantages over femoral nerve catheters for knee replacement patients because they produce less quadriceps muscle weakness; however, applying adductor canal catheters in bedside clinical practice remains challenging. There is currently no patient-reported outcome that accurately predicts patients’ physical function after knee replacement. The present study evaluates the validity of a relatively new patient-reported outcome, i.e., a numbness score obtained using a numeric rating scale, and assesses its predictive value on postoperative ambulation. Methods: We conducted a retrospective cohort study pooling data from two previously-published clinical trials using identical research methodologies. Both studies recruited patients undergoing knee replacement; one studied adductor canal catheters while the other studied femoral nerve catheters. Our primary outcome was patient-reported numbness scores on postoperative day 1. We also examined postoperative day 1 ambulation distance and its association with postoperative numbness using linear regression, adjusting for age, body mass index, and physical status. Results: Data from 94 subjects were included (femoral subjects, n = 46; adductor canal subjects, n = 48). Adductor canal patients reported decreased numbness (median [10th–90th percentiles]) compared to femoral patients (0 [0–5] vs. 4 [0–10], P = 0.001). Adductor canal patients also ambulated seven times further on postoperative day 1 relative to femoral patients. There was a significant association between postoperative day 1 total ambulation distance and numbness (Beta = −2.6; 95% CI: −4.5, −0.8, P = 0.01) with R2 = 0.1. Conclusions: Adductor canal catheters facilitate improved early ambulation and produce less patient-reported numbness after knee replacement, but the correlation between these two variables is weak.

      • KCI등재

        Using eye tracking technology to compare the effectiveness of malignant hyperthermia cognitive aid design

        Roderick King,Jaber Hanhan,T. Kyle Harrison,Alex Kou,Steven K. Howard,Lindsay K. Borg,Cynthia Shum,Ankeet D. Udani,Edward R. Mariano 대한마취통증의학회 2018 Korean Journal of Anesthesiology Vol.71 No.4

        Background: Malignant hyperthermia is a rare but potentially fatal complication of anesthesia, and several different cognitive aids designed to facilitate a timely and accurate response to this crisis currently exist. Eye tracking technology can measure voluntary and involuntary eye movements, gaze fixation within an area of interest, and speed of visual response and has been used to a limited extent in anesthesiology. Methods: With eye tracking technology, we compared the accessibility of five malignant hyperthermia cognitive aids by collecting gaze data from twelve volunteer participants. Recordings were reviewed and annotated to measure the time required for participants to locate objects on the cognitive aid to provide an answer; cumulative time to answer was the primary outcome. Results: For the primary outcome, there were differences detected between cumulative time to answer survival curves (P < 0.001). Participants demonstrated the shortest cumulative time to answer when viewing the Society for Pediatric Anesthesia (SPA) cognitive aid compared to four other publicly available cognitive aids for malignant hyperthermia, and this outcome was not influenced by the anesthesiologists’ years of experience. Conclusions: This is the first study to utilize eye tracking technology in a comparative evaluation of cognitive aid design, and our experience suggests that there may be additional applications of eye tracking technology in healthcare and medical education. Potentially advantageous design features of the SPA cognitive aid include a single page, linear layout, and simple typescript with minimal use of single color blocking.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼