RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        Design of an Integrated Inductor with Magnetic Core for Micro-Converter DC-DC Application

        Dhahri, Yassin,Ghedira, Sami,Besbes, Kamel The Korean Institute of Electrical and Electronic 2016 Transactions on Electrical and Electronic Material Vol.17 No.6

        This paper presents a design procedure of an integrated inductor with a magnetic core for power converters. This procedure considerably reduces design time and effort. The proposed design procedure is verified by the development of an inductor model dedicated to the monolithic integration of DC-DC converters for portable applications. The numerical simulation based on the FEM (finite elements method) shows that 3D modeling of the integrated inductor allows better estimation of the electrical parameters of the desired inductor. The optimization of the electrical parameter values is based on the numerical analysis of the influence of the geometric parameters on the electrical characteristics of the inductor. Using the VHDL-AMS language, implementation of the integrated inductor in a micro Buck converter demonstrate that simulation results present a very promising approach for the monolithic integration of DC-DC converters.

      • KCI등재

        Design of an Integrated Inductor with Magnetic Core for Micro-Converter DC-DC Application

        Yassin Dhahri,Sami Ghedira,Kamel Besbes 한국전기전자재료학회 2016 Transactions on Electrical and Electronic Material Vol.17 No.6

        This paper presents a design procedure of an integrated inductor with a magnetic core for power converters. Thisprocedure considerably reduces design time and effort. The proposed design procedure is verified by the developmentof an inductor model dedicated to the monolithic integration of DC-DC converters for portable applications. Thenumerical simulation based on the FEM (finite elements method) shows that 3D modeling of the integrated inductorallows better estimation of the electrical parameters of the desired inductor. The optimization of the electricalparameter values is based on the numerical analysis of the influence of the geometric parameters on the electricalcharacteristics of the inductor. Using the VHDL-AMS language, implementation of the integrated inductor in a microBuck converter demonstrate that simulation results present a very promising approach for the monolithic integrationof DC-DC converters.

      • KCI등재

        Ultrasound does not shorten the duration of procedure but provides a faster sensory and motor block onset in comparison to nerve stimulator in infraclavicular brachial plexus block

        walid Trabelsi,Mondher Belhaj Amor,Mohamed Anis Lebbi,Chiheb Romdhani,Sami Dhahri,Mustapha Ferjani 대한마취통증의학회 2013 Korean Journal of Anesthesiology Vol.64 No.4

        Background: Infraclaviculr Brachial plexus (ICBP) block is useful for upper extremity surgery. The aim of this study was to compare the ultrasound (US) technique with the nerve stimulation (NS) technique in their success rates and times to perform ICBP block. Methods: 60 patients undergoing surgery of the upper limb were randomly allocated into two groups (n = 30 per group). Group 1; US, and Group 2; NS. Procedure time (including time for initial ultrasound examination), the success rate and the onset time of sensory and motor blockade were assessed. Results: The time needed to perform the ICBP block is similar in both groups (220 seconds ± 130 in US group versus 281 ± 134 seconds in NS group; P = 0.74). The success rate of all the nerve blocks in the US group was 100%. The success rate in the NS group was 73.3%, 76.7%, 76.7% and 100% for radial, ulnar, medial, and musculocutaneous nerve, respectively. A significantly faster onset of sensory block for the radial, ulnar, median, musculocutaneous, and the four nerves considered together were observed. The onset of motor block for the radial, ulnar, and medial nerves was faster in the US group. However, the onset of motor block for the musculocutaneous nerve and the four nerves considered together was comparable between the two groups. Conclusions: The ultrasound-guided infraclavicular brachial plexus block is a significantly efficacious method with faster onset but similar procedure time compared to the nerve stimulation technique.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼