RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

        Arezki Menacer,Gerard Champenois,Mohamed Said Nait Said,Abdelhamid Benakcha,Sandrine Moreau,Said Hassaine 대한전기학회 2009 Journal of Electrical Engineering & Technology Vol.4 No.2

        The growing application and the numerous qualities of induction motors (IM) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ? the IM is directly by the balanced three-phase network voltage source, ? the IM is fed by a sinusoidal current source given the controlled by hysteresis, ? the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ? the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

      • SCIESCOPUSKCI등재

        Rotor Failures Diagnosis of Squirrel Cage Induction Motors with Different Supplying Sources

        Menacer, Arezki,Champenois, Gerard,Nait Said, Mohamed Said,Benakcha, Abdelhamid,Moreau, Sandrine,Hassaine, Said The Korean Institute of Electrical Engineers 2009 Journal of Electrical Engineering & Technology Vol.4 No.2

        The growing application and the numerous qualities of induction motors (1M) in industrial processes that require high security and reliability levels has led to the development of multiple methods for early fault detection. However, various faults can occur, such as stator short-circuits and rotor failures. Traditionally the diagnosis machine is done through a sinusoidal power supply, in the present paper we study experimentally the effects of the rotor failures, such as broken rotor bars in function of the ac supplying, the load and show the impact of the converter from diagnosis of the machine. The technique diagnosis used is based on the spectral analysis of stator currents or stator voltages respectively according to the types of induction motor ac supplying. So, four different ac supplying are considered: ${\odot}$ the IM is directly by the balanced three-phase network voltage source, ${\odot}$ the IM is fed by a sinusoidal current source given the controlled by hysteresis, ${\odot}$ the IM is fed (in open loop) by a scalar control imposing through ratio V/f=constant, ${\odot}$ the IM is controlled through a vector control using space vector pulse width modulation (SVPWM) technique inverter with an outer speed loop.

      • KCI등재

        Static analysis of the FGM plate with porosities

        R. Benferhat,T. Hassaine Daouadji,L. Hadji,M. Said Mansour 국제구조공학회 2016 Steel and Composite Structures, An International J Vol.21 No.1

        This work focuses on the behavior of the static analysis of functionally graded plates materials (FGMs) with porosities that may possibly occur inside the functionally graded materials (FGMs) during their fabrication. For this purpose a new refined plate theory is used in this work, it contains only four unknowns, unlike five unknowns for other theories. This new model meets the nullity of the transverse shear stress at the upper and lower surfaces of the plate. The parabolic distribution of transverse shear stresses along the thickness of the plate is taken into account in this analysis; the material properties of the FGM plate vary a power law distribution in terms of volume fraction of the constituents. The rule of mixture is modified to describe and approximate material properties of the FG plates with porosity phases. The validity of this theory is studied by comparing some of the present results with other higher-order theories reported in the literature, the influence of material parameter, the volume fraction of porosity and the thickness ratio on the behavior mechanical P-FGM plate are represented by numerical examples.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼