RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

        Rinke, Sven,Buergers, Ralf,Ziebolz, Dirk,Roediger, Matthias The Korean Academy of Prosthodonitics 2015 The Journal of Advanced Prosthodontics Vol.7 No.4

        PURPOSE. This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS. In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS. One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: $5.9{\pm}2.2years$), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION. Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

      • SCIESCOPUSKCI등재

        Risk indicators for mucositis and peri-implantitis: results from a practice-based cross-sectional study

        Rinke, Sven,Nordlohne, Marc,Leha, Andreas,Renvert, Stefan,Schmalz, Gerhard,Ziebolz, Dirk Korean Academy of Periodontology 2020 Journal of Periodontal & Implant Science Vol.50 No.3

        Purpose: This practice-based cross-sectional study aimed to investigate whether common risk indicators for peri-implant diseases were associated with peri-implant mucositis and peri-implantitis in patients undergoing supportive implant therapy (SIT) at least 5 years after implant restoration. Methods: Patients exclusively restored with a single implant type were included. Probing pocket depth (PPD), bleeding on probing (BOP), suppuration, and radiographic bone loss (RBL) were assessed around implants. The case definitions were as follows: peri-implant mucositis: PPD ≥4 mm, BOP, no RBL; and peri-implantitis: PPD ≥5 mm, BOP, RBL ≥3.5 mm. Possible risk indicators were compared between patients with and without mucositis and peri-implantitis using the Fisher exact test and the Wilcoxon rank-sum test, as well as a multiple logistic regression model for variables showing significance (P<0.05). Results: Eighty-four patients with 169 implants (observational period: 5.8±0.86 years) were included. A patient-based prevalence of 52% for peri-implant mucositis and 18% for peri-implantitis was detected. The presence of 3 or more implants (odds ratio [OR], 4.43; 95 confidence interval [CI], 1.36-15.05; P=0.0136) was significantly associated with an increased risk for mucositis. Smoking was significantly associated with an increased risk for peri-implantitis (OR, 5.89; 95% CI, 1.27-24.58; P=0.0231), while the presence of keratinized mucosa around implants was associated with a lower risk for peri-implantitis (OR, 0.05; 95% CI, 0.01-0.25; P<0.001). Conclusions: The number of implants should be considered in strategies to prevent mucositis. Furthermore, smoking and the absence of keratinized mucosa were the strongest risk indicators for peri-implantitis in patients undergoing SIT in the present study.

      • SCIESCOPUSKCI등재

        Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

        Rinke, Sven,Rasing, Hajo,Gersdorff, Nikolaus,Buergers, Ralf,Roediger, Matthias The Korean Academy of Prosthodonitics 2015 The Journal of Advanced Prosthodontics Vol.7 No.4

        PURPOSE. This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS. A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ${\geq}3.5mm$) was evaluated by digital analysis of panoramic radiographs taken postoperative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS. The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION. Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

      • KCI등재

        Risk indicators for mucositis and peri-implantitis: results from a practice-based cross-sectional study

        Sven Rinke,Marc Nordlohne,Andreas Leha,Stefan Renvert,Gerhard Schmalz,Dirk Ziebolz 대한치주과학회 2020 Journal of Periodontal & Implant Science Vol.50 No.3

        Purpose: This practice-based cross-sectional study aimed to investigate whether common risk indicators for peri-implant diseases were associated with peri-implant mucositis and peri-implantitis in patients undergoing supportive implant therapy (SIT) at least 5 years after implant restoration. Methods: Patients exclusively restored with a single implant type were included. Probing pocket depth (PPD), bleeding on probing (BOP), suppuration, and radiographic bone loss (RBL) were assessed around implants. The case definitions were as follows: peri-implant mucositis: PPD ≥4 mm, BOP, no RBL; and peri-implantitis: PPD ≥5 mm, BOP, RBL ≥3.5 mm. Possible risk indicators were compared between patients with and without mucositis and peri-implantitis using the Fisher exact test and the Wilcoxon rank-sum test, as well as a multiple logistic regression model for variables showing significance (P<0.05). Results: Eighty-four patients with 169 implants (observational period: 5.8±0.86 years) were included. A patient-based prevalence of 52% for peri-implant mucositis and 18% for peri-implantitis was detected. The presence of 3 or more implants (odds ratio [OR], 4.43; 95 confidence interval [CI], 1.36–15.05; P=0.0136) was significantly associated with an increased risk for mucositis. Smoking was significantly associated with an increased risk for peri-implantitis (OR, 5.89; 95% CI, 1.27–24.58; P=0.0231), while the presence of keratinized mucosa around implants was associated with a lower risk for peri-implantitis (OR, 0.05; 95% CI, 0.01–0.25; P<0.001). Conclusions: The number of implants should be considered in strategies to prevent mucositis. Furthermore, smoking and the absence of keratinized mucosa were the strongest risk indicators for peri-implantitis in patients undergoing SIT in the present study.

      • KCI등재

        Clinical outcome of double crown-retained implant overdentures with zirconia primary crowns

        Sven Rinke,Ralf Buergers,Dirk Ziebolz,Matthias Roediger2 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.4

        PURPOSE This retrospective study aims at the evaluation of implant-supported overdentures (IODs) supported by ceramo-galvanic double crowns (CGDCs: zirconia primary crowns + galvano-formed secondary crown). MATERIALS AND METHODS In a private practice, 14 patients were restored with 18 IODs (mandible: 11, maxilla: 7) retained by CGDCs on 4 - 8 implants and annually evaluated for technical and/or biological failures/complications. RESULTS One of the 86 inserted implants failed during the healing period (cumulative survival rate (CSR) implants: 98.8%). During the prosthetic functional period (mean: 5.9 ± 2.2 years), 1 implant demonstrated an abutment fracture (CSR-abutments: 98.2%), and one case of peri-implantitis was detected. All IODs remained in function (CSR-denture: 100%). A total of 15 technical complications required interventions to maintain function (technical complication rate: 0.178 treatments/patients/year). CONCLUSION Considering the small sample size, the use of CGDCs for the attachment of IODs is possible without an increased risk of technical complications. However, for a final evaluation, results from a larger cohort are required.

      • KCI등재

        Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

        Sven Rinke,Hajo Rasing,Nikolaus Gersdorff,Ralf Buergers,Matthias Roediger 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.4

        PURPOSE. This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS. A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ≥3.5 mm) was evaluated by digital analysis of panoramic radiographs taken postoperative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS. The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION. Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction.

      • KCI등재

        Implant-supported overdentures with different bar designs: A retrospective evaluation after 5-19 years of clinical function

        Sven Rinke,Hajo Rasing,Nikolaus Gersdorff,Ralf Buergers,Matthias Roediger 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.4

        PURPOSE This retrospective study evaluated the outcome of implant-retained overdentures (IODs) after 5-19 years of clinical function. MATERIALS AND METHODS A retrospective analysis of patient files was performed referring to 27 patients who received 36 IODs with 3 different bar designs (group A=prefabricated round bars, n=7; group B=one-piece anterior milled bars, n=20; and group C=two bilaterally placed milled bars, n=9) in the mandible (n=24) and/or in the maxilla (n=12). The analysis focused on the survival and success rates (according to Kaplan-Meier) of the implants and prostheses. Technical complication rates for each type of restoration were analyzed and compared via one-way ANOVA and the Chi-squared test. The prevalence of peri-implantitis (radiographic bone loss ≥3.5 mm) was evaluated by digital analysis of panoramic radiographs taken post-operative (baseline) and after 5-19 years of clinical function (follow-up). RESULTS The mean observational time was 7.3 years. The survival rates of the prostheses and implants were 100% and 97.7%, respectively. Technical complications occurred more frequently in group A (mean: 3.5 during observational time) than in the other two groups (B: 0.8; C: 1.0). However, this difference was not statistically significant (P=0.58). Peri-implantitis was diagnosed for 12.4% of the implants in 37% of the patients. CONCLUSION Bar-retained IODs are an adequate treatment option for edentulous jaws. These restorations may exhibit high implant/prosthesis survival rates (>97%), and a limited incidence of technical complications after a mean observational period of >7 years. Nevertheless, peri-implantitis was identified as a frequent and serious biological complication for this type of reconstruction

      • SCIESCOPUSKCI등재

        Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

        Rodiger, Matthias,Rinke, Sven,Ehret-Kleinau, Fenja,Pohlmeyer, Franziska,Lange, Katharina,Burgers, Ralf,Gersdorff, Nikolaus The Korean Academy of Prosthodonitics 2014 The Journal of Advanced Prosthodontics Vol.6 No.3

        PURPOSE. To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS. Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: $5.7^{\circ}$; customized-long, height: 6.79 mm, taper: $4.8^{\circ}$; customized-short, height: 4.31 mm, taper: $4.8^{\circ}$) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: $5.7^{\circ}$) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS. Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION. No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

      • SCIESCOPUSKCI등재

        Association of chairside salivary aMMP-8 findings with periodontal risk assessment parameters in patients receiving supportive periodontal therapy

        Schmalz, Gerhard,Kummer, Max Kristian,Kottmann, Tanja,Rinke, Sven,Haak, Rainer,Krause, Felix,Schmidt, Jana,Ziebolz, Dirk Korean Academy of Periodontology 2018 Journal of Periodontal & Implant Science Vol.48 No.4

        Purpose: The aim of this retrospective cross-sectional study was to evaluate whether salivary findings of active matrix-metalloproteinase 8 (aMMP-8) chairside (point of care; POC) tests were associated with periodontal risk assessment parameters in patients receiving supportive periodontal therapy (SPT). Methods: A total of 125 patients receiving regular SPT were included, and their records were examined. The following inclusion criteria were used: a diagnosis of chronic periodontitis, at least 1 non-surgical periodontal treatment (scaling and root planning) with following regular SPT (minimum once a year), at least 6 remaining teeth, and clinical and aMMP-8 findings that were obtained at the same appointment. In addition to anamnestic factors (e.g., smoking and diabetes), oral hygiene indices (modified sulcus bleeding index [mSBI] and approximal plaque index), periodontal probing depth simultaneously with bleeding on probing, and dental findings (number of decayed, missing, and filled teeth) were recorded. Salivary aMMP-8 levels were tested using a commercial POC test system (Periomarker, Hager & Werken, Duisburg, Germany). Statistical analysis was performed using the t-test, Mann-Whitney U test, Fisher's exact test, and ${\chi}^2$ test, as appropriate (P<0.05). Results: Only the mSBI was significantly associated with positive salivary aMMP-8 findings (aMMP-8 positive: $27.8%{\pm}20.9%$ vs. aMMP-8 negative: $18.0%{\pm}14.5%$; P=0.017). No significant associations were found between aMMP-8 and smoking, diabetes, periodontal parameters, or parameters related to the maintenance interval (P>0.05). Conclusions: Salivary aMMP-8 chairside findings were not associated with common parameters used for periodontal risk assessment in patients receiving SPT. The diagnostic benefit of POC salivary aMMP-8 testing in risk assessment and maintenance interval adjustment during SPT remains unclear.

      • SCIESCOPUSKCI등재

        Evaluation of removal forces of implant-supported zirconia copings depending on abutment geometry, luting agent and cleaning method during re-cementation

        Franziska Pohlmeyer,Katharina Lange,Ralf Burger Nikolaus Gersdorff,Fenja Ehret-Kleinau,Sven Rinke,Matthias ROdiger 대한치과보철학회 2014 The Journal of Advanced Prosthodontics Vol.6 No.3

        PURPOSE To evaluate the effects of different abutment geometries in combination with varying luting agents and the effectiveness of different cleaning methods (prior to re-cementation) regarding the retentiveness of zirconia copings on implants. MATERIALS AND METHODS Implants were embedded in resin blocks. Three groups of titanium abutments (pre-fabricated, height: 7.5 mm, taper: 5.7°; customized-long, height: 6.79 mm, taper: 4.8°; customized-short, height: 4.31 mm, taper: 4.8°) were used for luting of CAD/CAM-fabricated zirconia copings with a semi-permanent (Telio CS) and a provisional cement (TempBond NE). Retention forces were evaluated using a universal testing machine. Furthermore, the influence of cleaning methods (manually, manually in combination with ultrasonic bath or sandblasting) prior to re-cementation with a provisional cement (TempBond NE) was investigated with the pre-fabricated titanium abutments (height: 7.5 mm, taper: 5.7°) and SEM-analysis of inner surfaces of the copings was performed. Significant differences were determined via two-way ANOVA. RESULTS Significant interactions between abutment geometry and luting agent were observed. TempBond NE showed the highest level of retentiveness on customized-long abutments, but was negatively affected by other abutment geometries. In contrast, luting with Telio CS demonstrated consistent results irrespective of the varying abutment geometries. Manual cleaning in combination with an ultrasonic bath was the only cleaning method tested prior to re-cementation that revealed retentiveness levels not inferior to primary cementation. CONCLUSION No superiority for one of the two cements could be demonstrated because their influences on retentive strength are also depending on abutment geometry. Only manual cleaning in combination with an ultrasonic bath offers retentiveness levels after re-cementation comparable to those of primary luting.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼