RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Proinflammatory cytokine levels in oral lichen planus, oral leukoplakia, and oral submucous fibrosis

        Jasdeep Kaur,Reinhilde Jacobs 대한구강악안면외과학회 2015 대한구강악안면외과학회지 Vol.41 No.4

        Objectives: The objective of this study was to identify salivary and serum concentrations of interleukin (IL)-8, IL-6, and tumor necrosis factor alpha (TNF-α) in patients with oral lichen planus, oral leukoplakia, oral submucous fibrosis, and healthy controls. Materials and Methods: Patients selected included 54 oral lichen planus (41 to 65 years), 50 oral leukoplakia (42 to 65 years), 51 oral submucous fibrosis (41 to 65 years), and 50 healthy controls (42 to 65 years). Oral lichen planus, oral leukoplakia, and oral submucous fibrosis cases were diagnosed using histopathological analysis. Salivary and serum cytokine concentrations were measured using enzyme-linked immunoassay kits in all subjects. Results: The levels of serum and salivary TNF-α, IL-6, and IL-8 were statistically significantly increased in oral leukoplakia, submucous fibrosis, and lichen planus in contrast to normal healthy subjects (P<0.05). Serum and salivary correlation analysis revealed strong and highly significant correlations for TNF-α, IL-6, and IL-8 in all groups (r=0.72-0.82, P<0.05). Conclusion: Salivary and serum cytokines were also elevated when analyzed in oral precancerous lesions. Thus, salivary and serum IL-8, IL-6, and TNF-α levels might act as diagnostic markers for detection of oral precancer.

      • SCOPUSKCI등재

        Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

        Torres, Andres,Jacobs, Reinhilde,Lambrechts, Paul,Brizuela, Claudia,Cabrera, Carolina,Concha, Guillermo,Pedemonte, Maria Eugenia Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.45 No.2

        Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

      • KCI등재

        Characterization of mandibular molar root and canal morphology using cone beam computed tomography and its variability in Belgian and Chilean population samples

        Andres Torres,Reinhilde Jacobs,Paul Lambrechts,Claudia Brizuela,Carolina Cabrera,Guillermo Concha,María Eugenia Pedemonte 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.2

        Purpose: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. Materials and Methods: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. Results: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. Conclusion: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

      • SCOPUSKCI등재

        Reproducibility of the sella turcica landmark in three dimensions using a sella turcica-specific reference system

        Pittayapat, Pisha,Jacobs, Reinhilde,Odri, Guillaume A.,Vasconcelos, Karla De Faria,Willems, Guy,Olszewski, Raphael Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.45 No.1

        Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a three-dimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D Accuitomo$^{(R)}$ 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the Maxilim$^{(R)}$ software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p<0.005, interobserver precision: p<0.0011). Results: The intraobserver mean precision of all landmarks was <1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p<0.005). For the sella landmarks, the intraobserver mean precision ranged from $0.43{\pm}0.34mm$ to $0.51{\pm}0.46mm$. The intraobserver reproducibility was generally good. The overall interobserver mean precision was <1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p<0.0011). The interobserver reproducibility of sella landmarks was good, with >50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identification in a 3D model without being based on two-dimensional images derived from 3D data.

      • KCI등재

        Reproducibility of the sella turcica landmark in three dimensions using a sella turcicaspecific reference system

        Pisha Pittayapat,Reinhilde Jacobs,Guillaume A. Odri,Karla de Faria Vasconcelos,Guy Willems,Raphael Olszewski 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.1

        Purpose: This study was performed to assess the reproducibility of identifying the sella turcica landmark in a threedimensional (3D) model by using a new sella-specific landmark reference system. Materials and Methods: Thirty-two cone-beam computed tomographic scans (3D AccuitomoR 170, J. Morita, Kyoto, Japan) were retrospectively collected. The 3D data were exported into the Digital Imaging and Communications in Medicine standard and then imported into the MaxilimR software (Medicim NV, Sint-Niklaas, Belgium) to create 3D surface models. Five observers identified four osseous landmarks in order to create the reference frame and then identified two sella landmarks. The x, y, and z coordinates of each landmark were exported. The observations were repeated after four weeks. Statistical analysis was performed using the multiple paired t-test with Bonferroni correction (intraobserver precision: p.0.005, interobserver precision: p.0.0011). Results: The intraobserver mean precision of all landmarks was .1 mm. Significant differences were found when comparing the intraobserver precision of each observer (p.0.005). For the sella landmarks, the intraobserver mean precision ranged from 0.43?0.34 mm to 0.51?0.46 mm. The intraobserver reproducibility was generally good. The overall interobserver mean precision was .1 mm. Significant differences between each pair of observers for all anatomical landmarks were found (p.0.0011). The interobserver reproducibility of sella landmarks was good, with .50% precision in locating the landmark within 1 mm. Conclusion: A newly developed reference system offers high precision and reproducibility for sella turcica identificationin a 3D model without being based on two-dimensional images derived from 3D data.

      • SCOPUSKCI등재

        Gold-wire artifacts on diagnostic radiographs: A case report

        Keestra, Johan Anton Jochum,Jacobs, Reinhilde,Quirynen, Marc Korean Academy of Oral and Maxillofacial Radiology 2014 Imaging Science in Dentistry Vol.44 No.1

        This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

      • KCI등재

        How image-processing parameters can influence the assessment of dental materials using micro-CT

        Torres Fernanda Ferrari Esteves,Reinhilde Jacobs,Mostafa EzEldeen,Karla de Faria-Vasconcelos,Guerreiro-Tanomaru Juliane Maria,Bernardo Camargo dos Santos,Mário Tanomaru-Filho 대한영상치의학회 2020 Imaging Science in Dentistry Vol.50 No.2

        Purpose: The aim of this study was to evaluate the influence of voxel size and different post-processing algorithms on the analysis of dental materials using micro-computed tomography (micro-CT). Materials and Methods: Root-end cavities were prepared in extracted maxillary premolars, filled with mineral trioxide aggregate (MTA), Biodentine, and Intermediate Restorative Material (IRM), and scanned using micro- CT. The volume and porosity of materials were evaluated and compared using voxel sizes of 5, 10, and 20 μm, as well as different software tools (post-processing algorithms). The CTAn or MeVisLab/Materialise 3-matic software package was used to perform volume and morphological analyses, and the CTAn or MeVisLab/Amira software was used to evaluate porosity. Data were analyzed using 1-way ANOVA and the Tukey test (P<0.05). Results: Using MeVisLab/Materialise 3-matic, a consistent tendency was observed for volume to increase at larger voxel sizes. CTAn showed higher volumes for MTA and IRM at 20 μm. Using CTAn, porosity values decreased as voxel size increased, with statistically significant differences for all materials. MeVisLab/Amira showed a difference for MTA and IRM at 5 μm, and for Biodentine at 20 μm. Significant differences in volume and porosity were observed in all software packages for Biodentine across all voxel sizes. Conclusion: Some differences in volume and porosity were found according to voxel size, image-processing software, and the radiopacity of the material. Consistent protocols are needed for research evaluating dental materials.

      • KCI등재

        Gold-wire artifacts on diagnostic radiographs: A case report

        Johan Anton Jochum Keestra,Reinhilde Jacobs,Marc Quirynen 대한영상치의학회 2014 Imaging Science in Dentistry Vol.44 No.1

        This report described a case in which diagnostic radiographs showed irregular dense radiopaque strings and curved lines in the head and neck area. These artifacts could lead to misinterpretation since they may obscure anatomical structures and/or mask critical structures/pathologies. A more detailed history of the patient indicated that these strings originated from a facelift procedure in which a gold-wire technique was used. Considering that such intervention may cause a radiodiagnostic burden, it should be included in the anamnesis prior to radiography.

      • KCI등재

        How do imaging protocols affect the assessment of root-end fillings?

        Torres Fernanda Ferrari Esteves,Jacobs Reinhilde,EzEldeen Mostafa,de Faria-Vasconcelos Karla,Guerreiro-Tanomaru Juliane Maria,dos Santos Bernardo Camargo,Tanomaru-Filho Mário 대한치과보존학회 2022 Restorative Dentistry & Endodontics Vol.47 No.1

        Objectives This study investigated the impact of micro-computed tomography (micro-CT)-based voxel size on the analysis of material/dentin interface voids and thickness of different endodontic cements. Materials and Methods Following root-end resection and apical preparation, maxillary premolars were filled with mineral trioxide aggregate (MTA), Biodentine, and intermediate restorative material (IRM) (n = 24). The samples were scanned using micro-CT (SkyScan 1272; Bruker) and the cement/dentin interface and thickness of materials were evaluated at voxel sizes of 5, 10, and 20 µm. Analysis of variance and the Tukey test were conducted, and the degree of agreement between different voxel sizes was evaluated using the Bland and Altman method (p < 0.05). Results All materials showed an increase in thickness from 5 to 10 and 20 µm (p < 0.05). When evaluating the interface voids, materials were similar at 5 µm (p > 0.05), while at 10 and 20 µm Biodentine showed the lowest percentage of voids (p < 0.05). A decrease in the interface voids was observed for MTA and IRM at 20 µm, while Biodentine showed differences among all voxel sizes (p < 0.05). The Bland-Altman plots for comparisons among voxel sizes showed the largest deviations when comparing images between 5 and 20 µm. Conclusions Voxel size had an impact on the micro-CT evaluation of thickness and interface voids of endodontic materials. All cements exhibited an increase in thickness and a decrease in the void percentage as the voxel size increased, especially when evaluating images at 20 µm.

      • KCI등재

        Preoperative implant planning considering alveolar bone grafting needs and complication prediction using panoramic versus CBCT images

        Maria Eugenia Guerrero,Jorge Noriega,Reinhilde Jacobs 대한영상치의학회 2014 Imaging Science in Dentistry Vol.44 No.3

        Purpose: This study was performed to determine the efficacy of observers’ prediction for the need of bone grafting and presence of perioperative complications on the basis of cone-beam computed tomography (CBCT) and panoramic radiographic (PAN) planning as compared to the surgical outcome. Materials and Methods: One hundred and eight partially edentulous patients with a need for implant rehabilitation were referred for preoperative imaging. Imaging consisted of PAN and CBCT images. Four observers carried out implant planning using PAN image datasets, and at least one month later, using CBCT image datasets. Based on their own planning, the observers assessed the need for bone graft augmentation as well as complication prediction. The implant length and diameter, the need for bone graft augmentation, and the occurrence of anatomical complications during planning and implant placement were statistically compared. Results: In the 108 patients, 365 implants were installed. Receiver operating characteristic analyses of both PAN and CBCT preoperative planning showed that CBCT performed better than PAN-based planning with respect to the need for bone graft augmentation and perioperative complications. The sensitivity and the specificity of CBCT forimplant complications were 96.5% and 90.5%, respectively, and for bone graft augmentation, they were 95.2% and 96.3%, respectively. Significant differences were found between PAN-based planning and the surgery of posterior implant lengths. Conclusion: Our findings indicated that CBCT-based preoperative implant planning enabled treatment planning with a higher degree of prediction and agreement as compared to the surgical standard. In PAN-based surgery, the prediction of implant length was poor.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼