RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        The chronology of second molar development in Brazilians and its application to forensic age estimation

        Almeida, Manuella Santos Carneiro,Pontual, Andrea Dos Anjos,Beltrao, Rejane Targino,Beltrao, Ricardo Villar,Pontual, Maria Luiza Dos Anjos Korean Academy of Oral and Maxillofacial Radiology 2013 Imaging Science in Dentistry Vol.43 No.1

        Purpose: This study investigated the possible correlation between the mineralization of the second molars and the chronological age of a sample population of the state of Paraiba, Brazil. Materials and Methods: One thousand eight hundred fifty-four digitized panoramic images using a scanner of a private dental radiology service were obtained in six months. Of these, 457 were selected from patients aged 4.6 to 16 years who met certain criteria. The images were assessed twice by a radiologist with 5 years experience. A minimum interval of 30 days between the evaluations of the same patient was established. To analyze the relationship between chronological age, calcification level proposed by Demirjian et al in 1973, gender, and tooth, a multiple linear regression model was adjusted, taking age as the response variable (p<0.05). Results: The gender and calcification level were significantly correlated with the age of the patients (p<0.05). There was a significant difference between the average age of the patients' upper teeth compared to the lower ones in both genders (p<0.05). The dental development occurred earlier in female individuals than in male ones, and there was no significant difference between the right and left second permanent molars. Conclusion: It was observed that ethnic variables are related to certain parameters of age and sex identification in the Brazilian population, providing important information for forensic evaluations.

      • KCI등재
      • SCOPUSKCI등재

        Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography

        Nascimento, Eduarda Helena Leandro do,Pontual, Maria Luiza dos Anjos,Pontual, Andrea dos Anjos,Perez, Danyel Elias da Cruz,Figueiroa, Jose Natal,Frazao, Marco Antonio Gomes,Ramos-Perez, Flavia Maria d Korean Academy of Oral and Maxillofacial Radiology 2016 Imaging Science in Dentistry Vol.46 No.2

        Purpose: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, $1.1{\pm}0.8mm$). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.

      • KCI등재

        The chronology of second molar development in Brazilians and its application to forensic age estimation

        Manuella Santos Carneiro Almeida,Andrea dos Anjos Pontual,Rejane Targino Beltrao,Ricardo Villar Beltrao,Maria Luiza dos Anjos Pontual 대한구강악안면방사선학회 2013 Imaging Science in Dentistry Vol.43 No.1

        Purpose: This study investigated the possible correlation between the mineralization of the second molars and the chronological age of a sample population of the state of Paraiba, Brazil. Materials and Methods: One thousand eight hundred fifty-four digitized panoramic images using a scanner of a private dental radiology service were obtained in six months. Of these, 457 were selected from patients aged 4.6 to 16 years who met certain criteria. The images were assessed twice by a radiologist with 5 years experience. A minimum interval of 30 days between the evaluations of the same patient was established. To analyze the relationship between chronological age, calcification level proposed by Demirjian et al in 1973, gender, and tooth, a multiple linear regression model was adjusted, taking age as the response variable (p⁄0.05). Results: The gender and calcification level were significantly correlated with the age of the patients (p⁄0.05). There was a significant difference between the average age of the patients’ upper teeth compared to the lower ones in both genders (p⁄0.05). The dental development occurred earlier in female individuals than in male ones, and there was no significant difference between the right and left second permanent molars. Conclusion: It was observed that ethnic variables are related to certain parameters of age and sex identification in the Brazilian population, providing important information for forensic evaluations.

      • KCI등재

        Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography

        Eduarda Helena Leandro do Nascimento,Maria Luiza dos Anjos Pontual,Andréa dos Anjos Pontual,Danyel Elias da Cruz Perez,José Natal Figueiroa,Marco Antônio Gomes Frazão,Flávia Maria de Moraes Ramos-Pere 대한영상치의학회 2016 Imaging Science in Dentistry Vol.46 No.2

        Purpose: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles. Materials and Methods CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Anatomic Variation; Cone-Beam Computed Tomography; Mandible Results An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases ... Purpose: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles. Materials and Methods CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, 1.1±0.8 mm). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.

      • SCOPUSKCI등재

        Positioning errors of dental implants and their associations with adjacent structures and anatomical variations: A CBCT-based study

        Ribas, Beatriz Ribeiro,Nascimento, Eduarda Helena Leandro,Freitas, Deborah Queiroz,Pontual, Andrea dos Anjos,Pontual, Maria Luiza dos Anjos,Perez, Danyel Elias Cruz,Ramos-Perez, Flavia Maria Moraes Korean Academy of Oral and Maxillofacial Radiology 2020 Imaging Science in Dentistry Vol.50 No.4

        Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.

      • KCI등재

        Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

        Fontenele Rocharles Cavalcante,Nascimento Eduarda Helena Leandro,Imbelloni-Vasconcelos Ana Catarina,Martins Luciano Augusto Cano,Pontual Andrea dos Anjos,Ramos-Perez Flávia Maria Moraes,Freitas Debora 대한영상치의학회 2022 Imaging Science in Dentistry Vol.52 No.3

        Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

      • SCIEKCI등재

        Effects of Opuntia ficus-indica lectin on feeding, survival, and gut enzymes of maize weevil, Sitophilus zeamais

        Souza, Carolina de Santana,Procopio, Thamara Figueiredo,Belmonte, Bernardo do Rego,Paiva, Patricia Maria Guedes,de Albuquerque, Lidiane Pereira,Pontual, Emmanuel Viana,Napoleao, Thiago Henrique The Korean Society for Applied Biological Chemistr 2018 Applied Biological Chemistry (Appl Biol Chem) Vol.61 No.3

        In this study, the effects of Opuntia ficus-indica lectin (OfiL) on the survival and nutritional parameters of Sitophilus zeamais (maize weevil) adults were evaluated. OfiL was incorporated into the artificial diets at concentrations of 15, 60, and 95 mg/g (mg of lectin per g of wheat flour). Mortality was evaluated after 7 and 15 days, and the amount of food ingested and the weight of the insects were determined on the 7th day. In addition, the in vitro effects of OfiL on the gut enzymes of the insect were investigated. The ingestion of OfiL did not show any significant difference in the mortality rates compared to control. The relative consumption rate was also similar to that of the control, and no deterrent effect was detected. However, the values of the relative biomass variation and the efficiency of ingested food conversion were negative in the treatments at 60 and 95 mg/g, showing that lectin ingestion resulted in weight loss. OfiL exhibited a stimulatory effect on the protease activity from S. zeamais gut extract, which may cause uncontrolled hydrolysis of proteins in the digestive tract. This lectin did not promote significant alteration in the amylase activity. In conclusion, OfiL was able to exert anti-nutritional effects without causing a deterrent effect.

      • SCOPUSKCI등재

        Influence of kilovoltage- peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants

        Fontenele, Rocharles Cavalcante,Nascimento, Eduarda Helena Leandro,Imbelloni-Vasconcelos, Ana Catarina,Martins, Luciano Augusto Cano,Pontual, Andrea dos Anjos,Ramos-Perez, Flavia Maria Moraes,Freitas, Korean Academy of Oral and Maxillofacial Radiology 2022 Imaging Science in Dentistry Vol.52 No.-

        Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.

      • KCI등재

        Radiopacity of restorative composites by conventional radiograph and digital images with different resolutions

        Raquel Venâncio Fernandes Dantas,Hugo Ramalho Sarmento,Rosângela Marques Duarte,Sônia Saeger Meireles Monte Raso,Ana Karina Maciel de Andrade,Maria Luiza dos Anjos Pontual 대한영상치의학회 2013 Imaging Science in Dentistry Vol.43 No.3

        Purpose: This study was performed to evaluate and compare the radiopacity of dentin, enamel, and 8 restorative composites on conventional radiograph and digital images with different resolutions. Materials and Methods: Specimens were fabricated from 8 materials and human molars were longitudinally sectioned 1.0 mm thick to include both enamel and dentin. The specimens and tooth sections were imaged by conventional radiograph using #4 sized intraoral film and digital images were taken in high speed and high resolution modes using a phosphor storage plate. Densitometric evaluation of the enamel, dentin, restorative materials, a lead sheet, and an aluminum step wedge was performed on the radiographic images. For the evaluation, the Al equivalent (mm) for each material was calculated. The data were analyzed using one-way ANOVA and Tukey’s test (p⁄0.05), considering the material factor and then the radiographic method factor, individually. Results: The high speed mode allowed the highest radiopacity, while the high resolution mode generated the lowest values. Furthermore, the high resolution mode was the most efficient method for radiographic differentiation between restorative composites and dentin. The conventional radiograph was the most effective in enabling differentiation between enamel and composites. The high speed mode was the least effective in enabling radiographic differentiation between the dental tissues and restorative composites. Conclusion: The high speed mode of digital imaging was not effective for differentiation between enamel and composites. This made it less effective than the high resolution mode and conventional radiographs. All of the composites evaluated showed radiopacity values that fit the ISO 4049 recommendations.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼