http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Almeida, Manuella Santos Carneiro,Pontual, Andrea Dos Anjos,Beltrao, Rejane Targino,Beltrao, Ricardo Villar,Pontual, Maria Luiza Dos Anjos Korean Academy of Oral and Maxillofacial Radiology 2013 Imaging Science in Dentistry Vol.43 No.1
Purpose: This study investigated the possible correlation between the mineralization of the second molars and the chronological age of a sample population of the state of Paraiba, Brazil. Materials and Methods: One thousand eight hundred fifty-four digitized panoramic images using a scanner of a private dental radiology service were obtained in six months. Of these, 457 were selected from patients aged 4.6 to 16 years who met certain criteria. The images were assessed twice by a radiologist with 5 years experience. A minimum interval of 30 days between the evaluations of the same patient was established. To analyze the relationship between chronological age, calcification level proposed by Demirjian et al in 1973, gender, and tooth, a multiple linear regression model was adjusted, taking age as the response variable (p<0.05). Results: The gender and calcification level were significantly correlated with the age of the patients (p<0.05). There was a significant difference between the average age of the patients' upper teeth compared to the lower ones in both genders (p<0.05). The dental development occurred earlier in female individuals than in male ones, and there was no significant difference between the right and left second permanent molars. Conclusion: It was observed that ethnic variables are related to certain parameters of age and sex identification in the Brazilian population, providing important information for forensic evaluations.
Manuella Santos Carneiro Almeida,Andrea dos Anjos Pontual,Rejane Targino Beltrao,Ricardo Villar Beltrao,Maria Luiza dos Anjos Pontual 대한구강악안면방사선학회 2013 Imaging Science in Dentistry Vol.43 No.1
Purpose: This study investigated the possible correlation between the mineralization of the second molars and the chronological age of a sample population of the state of Paraiba, Brazil. Materials and Methods: One thousand eight hundred fifty-four digitized panoramic images using a scanner of a private dental radiology service were obtained in six months. Of these, 457 were selected from patients aged 4.6 to 16 years who met certain criteria. The images were assessed twice by a radiologist with 5 years experience. A minimum interval of 30 days between the evaluations of the same patient was established. To analyze the relationship between chronological age, calcification level proposed by Demirjian et al in 1973, gender, and tooth, a multiple linear regression model was adjusted, taking age as the response variable (p⁄0.05). Results: The gender and calcification level were significantly correlated with the age of the patients (p⁄0.05). There was a significant difference between the average age of the patients’ upper teeth compared to the lower ones in both genders (p⁄0.05). The dental development occurred earlier in female individuals than in male ones, and there was no significant difference between the right and left second permanent molars. Conclusion: It was observed that ethnic variables are related to certain parameters of age and sex identification in the Brazilian population, providing important information for forensic evaluations.
Assessment of the anterior loop of the mandibular canal: A study using cone-beam computed tomography
Nascimento, Eduarda Helena Leandro do,Pontual, Maria Luiza dos Anjos,Pontual, Andrea dos Anjos,Perez, Danyel Elias da Cruz,Figueiroa, Jose Natal,Frazao, Marco Antonio Gomes,Ramos-Perez, Flavia Maria d Korean Academy of Oral and Maxillofacial Radiology 2016 Imaging Science in Dentistry Vol.46 No.2
Purpose: Sufficient area in the interforaminal region is required for dental implant placement, and the anterior loop of the mandibular canal is located within the limits of this area. The aim of this study was to evaluate the prevalence and extent of the anterior loop in a Brazilian sample population using cone-beam computed tomography (CBCT). Materials and Methods: CBCT images from 250 patients (500 hemimandibles) obtained for various clinical indications were randomly selected and evaluated to determine the presence and length of the anterior loop. The length of the anterior loop was then compared based on gender, age, and the side of the mandible. The data were analyzed using the Pearson chi-square test and linear regression analysis. Results: An anterior loop was identified in 41.6% of the cases, and its length ranged from 0.25 mm to 4.00 mm (mean, $1.1{\pm}0.8mm$). The loop had a greater mean length and was significantly more prevalent in males (p=0.014). No significant differences were found between the right and left sides regarding length (p=0.696) or prevalence (p=0.650). Conclusion: In this study, a high prevalence of the anterior loop of the mandibular canal was found, and although its length varied greatly, in most cases it was less than 1 mm long. Although this is a prevalent anatomical variation, safety limits for the placement of implants in this region cannot be established before an accurate evaluation using imaging techniques in order to identify and preserve the neurovascular bundles.
Ribas, Beatriz Ribeiro,Nascimento, Eduarda Helena Leandro,Freitas, Deborah Queiroz,Pontual, Andrea dos Anjos,Pontual, Maria Luiza dos Anjos,Perez, Danyel Elias Cruz,Ramos-Perez, Flavia Maria Moraes Korean Academy of Oral and Maxillofacial Radiology 2020 Imaging Science in Dentistry Vol.50 No.4
Purpose: The objective of the present study was to evaluate the prevalence of dental implants positioning errors and their associations with adjacent structures and anatomical variations by means of cone-beam computed tomography (CBCT). Materials and Methods: CBCT images of 207 patients (584 dental implants) were evaluated by 2 oral radiologists. The distance between the implant and the adjacent teeth/implants was measured and classified as adequate (≥1.5 mm and ≥3 mm, respectively) or inadequate. The presence of thread exposure, cortical perforation, implant dehiscence, implant penetration into adjacent structures, and anatomical variations was also recorded. The incisor canal diameter and the depth of the concavity of the submandibular fossa were measured in order to evaluate their correlations with the frequency of implant penetration in these structures. Descriptive analyses, the Fisher exact test, and Spearman correlation analysis were performed (α=0.05). Results: The overall prevalence of positioning errors was 82.9%. The most common error was the inadequate distance between the implant and the adjacent teeth/implants. The presence of anatomical variations did not significantly influence the overall prevalence of errors (P>0.05). There was a positive correlation between the diameter of the incisor canal and the frequency of implant penetration in this structure (r=0.232, P<0.05). Conclusion: There was a high prevalence of dental implant positioning errors, and positioning errors were not associated with the presence of anatomical variations. Professionals should be aware of the space available for implant placement during the preoperative planning stage.
Fontenele Rocharles Cavalcante,Nascimento Eduarda Helena Leandro,Imbelloni-Vasconcelos Ana Catarina,Martins Luciano Augusto Cano,Pontual Andrea dos Anjos,Ramos-Perez Flávia Maria Moraes,Freitas Debora 대한영상치의학회 2022 Imaging Science in Dentistry Vol.52 No.3
Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.
Fontenele, Rocharles Cavalcante,Nascimento, Eduarda Helena Leandro,Imbelloni-Vasconcelos, Ana Catarina,Martins, Luciano Augusto Cano,Pontual, Andrea dos Anjos,Ramos-Perez, Flavia Maria Moraes,Freitas, Korean Academy of Oral and Maxillofacial Radiology 2022 Imaging Science in Dentistry Vol.52 No.-
Purpose: The aim of this study was to assess the influence of kilovoltage- peak (kVp) and the metal artifact reduction (MAR) tool on the detection of buccal and lingual peri-implant dehiscence in the presence of titanium-zirconia (Ti-Zr) and zirconia (Zr) implants in cone-beam computed tomography (CBCT) images. Materials and Methods: Twenty implant sites were created in the posterior region of human mandibles, including control sites (without dehiscence) and experimental sites (with dehiscence). Individually, a Ti-Zr or Zr implant was placed in each implant site. CBCT scans were performed using a Picasso Trio device, with variation in the kVp setting (70 or 90 kVp) and whether the MAR tool was used. Three oral radiologists scored the detection of dehiscence using a 5-point scale. The area under the receiver operating characteristic (ROC) curve, sensitivity, and specificity were calculated and compared by multi-way analysis of variance (α=0.05). Results: The kVp, cortical plate involved (buccal or lingual cortices), and MAR did not influence any diagnostic values (P>0.05). The material of the implant did not influence the ROC curve values(P>0.05). In contrast, the sensitivity and specificity were statistically significantly influenced by the implant material (P<0.05) with Zr implants showing higher sensitivity values and lower specificity values than Ti-Zr implants. Conclusion: The detection of peri-implant dehiscence was not influenced by kVp, use of the MAR tool, or the cortical plate. Greater sensitivity and lower specificity were shown for the detection of peri-implant dehiscence in the presence of a Zr implant.