RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

        Di Stefano, Danilo Alessio,Arosio, Paolo,Piattelli, Adriano,Perrotti, Vittoria,Iezzi, Giovanna The Korean Academy of Prosthodonitics 2015 The Journal of Advanced Prosthodontics Vol.7 No.1

        PURPOSE. Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS. A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS. The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION. The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

      • KCI등재

        A torque-measuring micromotor provides operator independent measurements marking four different density areas in maxillae

        Vittoria Perrotti,Adriano Piattelli,Giovanna Iezzi,Paolo Arosio,Danilo Alessio Di Stefano 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.1

        PURPOSE Bone density at implant placement site is a key factor to obtain the primary stability of the fixture, which, in turn, is a prognostic factor for osseointegration and long-term success of an implant supported rehabilitation. Recently, an implant motor with a bone density measurement probe has been introduced. The aim of the present study was to test the objectiveness of the bone densities registered by the implant motor regardless of the operator performing them. MATERIALS AND METHODS A total of 3704 bone density measurements, performed by means of the implant motor, were registered by 39 operators at different implant sites during routine activity. Bone density measurements were grouped according to their distribution across the jaws. Specifically, four different areas were distinguished: a pre-antral (between teeth from first right maxillary premolar to first left maxillary premolar) and a sub-antral (more distally) zone in the maxilla, and an interforaminal (between and including teeth from first left mandibular premolar to first right mandibular premolar) and a retroforaminal (more distally) zone in the lower one. A statistical comparison was performed to check the inter-operators variability of the collected data. RESULTS The device produced consistent and operator-independent bone density values at each tooth position, showing a reliable bone-density measurement. CONCLUSION The implant motor demonstrated to be a helpful tool to properly plan implant placement and loading irrespective of the operator using it.

      • KCI등재

        The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs

        Danilo Alessio Di Stefano,Vittoria Perrotti,Gian Battista Greco,Claudia Cappucci,Paolo Arosio,Adriano Piattelli,Giovanna Iezzi 대한치과보철학회 2018 The Journal of Advanced Prosthodontics Vol.10 No.3

        PURPOSE. Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. MATERIALS AND METHODS. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-toimplant contact measured and statistically correlated to bone density and the integral. RESULTS. Bone-toimplant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. CONCLUSION. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼