RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUSKCI등재

        Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

        Obais, Abdulkareem Mokif,Pasupuleti, Jagadeesh The Korean Institute of Power Electronics 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.4

        In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

      • KCI등재

        Automatic Power Factor Correction Using a Harmonic-Suppressed TCR Equipped with a New Adaptive Current Controller

        Abdulkareem Mokif Obais,Jagadeesh Pasupuleti 전력전자학회 2014 JOURNAL OF POWER ELECTRONICS Vol.14 No.4

        In this paper, a new continuously and linearly controlled capacitive static VAR compensator is proposed for the automatic power factor correction of inductive single phase loads in 220V 50Hz power system networks. The compensator is constructed of a harmonic-suppressed TCR equipped with a new adaptive current controller. The harmonic-suppressed TCR is a new configuration that includes a thyristor controlled reactor (TCR) shunted by a passive third harmonic filter. In addition, the parallel configuration is connected to an AC source via a series first harmonic filter. The harmonic-suppressed TCR is designed so that negligible harmonic current components are injected into the AC source. The compensator is equipped with a new adaptive closed loop current controller, which responds linearly to reactive current demands. The no load operating losses of this compensator are negligible when compared to its capacitive reactive current rating. The proposed system is validated on PSpice which is very close in terms of performance to real hardware.

      • KCI등재

        The efficacy of ultrasonography in monitoring the healing of jaw lesions

        Obai Zainedeen,Iyad Al Haffar,Nabil Kochaji,George Wassouf 대한영상치의학회 2018 Imaging Science in Dentistry Vol.48 No.3

        Purpose: This study aimed to assess the reliability of ultrasonography (US) in comparison with cone-beam computed tomography (CBCT) as a tool for monitoring the healing of jaw lesions. Materials and Methods: Twenty-one radiolucent lesions in jaws referred to the Oral Surgery Department at our institution were selected for this study. All lesions underwent CBCT and US examinations. The anteroposterior, superoinferior, and mesiodistal dimensions of the lesions were measured on CBCT and US images before surgery and at 6 months after surgery. The dimensions were compared between the US and CBCT images. Blood-flow velocity around the lesions was measured by color Doppler before surgery and at 1 week and 6 months after surgery to assess the capability of US to show changes in blood-flow velocity around the lesion. Results: Before surgery, there were no significant differences between US and CBCT in the mesiodistal and anteroposterior dimensions, although a significant difference was found in the superoinferior dimension (P<.05). However, at 6 months after surgery, significant differences were found between US and CBCT in all dimensions, and it is likely that the US measurements more accurately reflected the extent of healing. The average blood-flow velocity increased at 1 week after surgery (5.84 cm/s) compared with the velocity before surgery (4 cm/s) (P<.05). Then, at 6 months after surgery, the blood-flow velocity significantly decreased (3.53 cm/s) compared to the velocity measured at 1 week after surgery (P<.05). Conclusion: US with color Doppler was confirmed to be a more efficient tool than CBCT for monitoring bone healing.

      • SCOPUSKCI등재

        The efficacy of ultrasonography in monitoring the healing of jaw lesions

        Zainedeen, Obai,Haffar, Iyad Al,Kochaji, Nabil,Wassouf, George Korean Academy of Oral and Maxillofacial Radiology 2018 Imaging Science in Dentistry Vol.48 No.3

        Purpose: This study aimed to assess the reliability of ultrasonography (US) in comparison with cone-beam computed tomography (CBCT) as a tool for monitoring the healing of jaw lesions. Materials and Methods: Twenty-one radiolucent lesions in jaws referred to the Oral Surgery Department at our institution were selected for this study. All lesions underwent CBCT and US examinations. The anteroposterior, superoinferior, and mesiodistal dimensions of the lesions were measured on CBCT and US images before surgery and at 6 months after surgery. The dimensions were compared between the US and CBCT images. Blood-flow velocity around the lesions was measured by color Doppler before surgery and at 1 week and 6 months after surgery to assess the capability of US to show changes in blood-flow velocity around the lesion. Results: Before surgery, there were no significant differences between US and CBCT in the mesiodistal and anteroposterior dimensions, although a significant difference was found in the superoinferior dimension (P<.05). However, at 6 months after surgery, significant differences were found between US and CBCT in all dimensions, and it is likely that the US measurements more accurately reflected the extent of healing. The average blood-flow velocity increased at 1 week after surgery (5.84 cm/s) compared with the velocity before surgery (4 cm/s) (P<.05). Then, at 6 months after surgery, the blood-flow velocity significantly decreased (3.53 cm/s) compared to the velocity measured at 1 week after surgery (P<.05). Conclusion: US with color Doppler was confirmed to be a more efficient tool than CBCT for monitoring bone healing.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼