http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Ngan K. Hoang,우영진,이상국 한국과학기술원 반도체설계교육센터 2015 IDEC Journal of Integrated Circuits and Systems Vol.1 No.1
At light load condition, buck converter usually requires a zero-current detector (ZCD) to prevent reverse current flowing back to the source to improve conversion efficiency. This paper presents a ZCD with enhanced time response of the freewheel switch operation. The proposed ZCD was simulated using a 0.18-µm CMOS process in a PWM voltage mode control type-III compensation buck converter, to convert a DC input voltage of 3.3V to a DC output voltage of 1.8V. The buck converter was designed to work in CCM at heavy load, PFM at light load, and DCM in a short transient between CCM and PFM. The PWM switching frequency is 2MHz, and the output load current range is from 20mA up to 300mA. The proposed ZCD was tested as compared to the conventional one for the same condition, showing maximum improvement of 6.9% in efficiency in PFM, making the overall conversion efficiency greater than 89.7%.