http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
강나루,우영아,김효진 동덕여자대학교 종합약학연구소 2001 동덕약학연구지 Vol.5 No.-
The purpose of this study is to develop a noninvasive blood glucose measurement method by using near infrared spectroscopy (NIRS). Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were Recoreded by using a fiber optic probe. The spectra were collected over the spectral range 1100-1700nm. Partial least squares regression (PLS) was applied for the calibration and validation for the determination of blood glucose. The calibration with the use of PLS model predicted for validation set glucose concentration with a standard error of prediction (SEP) of 33㎎/㎗.
석면 해체,제거 작업에서 사용되는 장비의 성능 기준에 관한 고찰
이나루 ( Na Roo Lee ) 한국산업위생학회 2013 한국산업보건학회지 Vol.23 No.3
Objectives: Asbestos fibers are accumulated in negative pressure unit(NPU) or vacuum cleaner in asbestos removal. Failure of operation or poor use performance of the NPU or vacuum cleaner causes asbestos fibers to spread in the air. Asbestos contractors should have an NPU fitted with a HEPA , vacuum cleaner, decontamination area, respirators, wetting equipment, and differential pressure manometer to register with the Ministry of Employment and Labor. There should be performance criteria of equipment used in asbestos removal. But there are none such criteria used in asbestos removal. This study was performed to investigate international or national performance criteria of equipment used in asbestos removal. Methods: Regulations, approved code of practice, guidance and national standards of the UK, USA and Korea were reviewed. A survey was done to investigate the requirements for equipment used in asbestos removal in Korea. Results: Air flow of NPUs used in Korea usually covers from 500 ㎥/h to over 3000 ㎥/h. Some requirements for NPUs used in Korea were missing compared to the requirements of British standards for NPUs. All NPUs have different missing requirements. The UK also has separate British standard for leak tests for NPUs. Highly hazardous class vacuum cleaners should be used in asbestos removal in the UK. It has national standards on the operation of vacuum cleaners used in asbestos removal. There is only a certification system for less than 2.5kw rated voltage vacuum cleaners for home use in Korea. Powered(-assisted) respirators with mask are recommended in asbestos removal. Type 5 coveralls should be used in asbestos removal in the UK. There are international standards for requirements and leak tests of type 5 coveralls. A manometer for measuring differential pressure is needed in asbestos removal. The manometer`s measuring range should cover less than ±125 Pa and the gradation of manometer should be less than 2.5 Pa. The definition of decontamination area should be corrected. Installation of airlock and minimum area should be considered in decontamination area. Conclusions: Equipment should be used in asbestos removal proper performance and no leaks. There should be a certification system for equipment used in asbestos removal. This study can help to a certification system for equipment used in asbestos removal in Korea.
강나루(Na Roo Kang),우영아(Young Ah Woo),차봉수(Bong Soo Cha),이현철(Hyun Chul Lee),김효진(Hyo Jin Kim) 대한약학회 2002 약학회지 Vol.46 No.5
The purpose of this study is to develop a non-invasive blood glucose measurement method by a portable near infrared (NIR) system which was newly integrated by our lab. The portable NIR system includes a tungsten halogen lamp, a specialized reflectance fiber optic probe and a photo diode array type InGaAs detector, which was developed by a microchip technology based on the lithography: Reflectance NIR spectra of different parts of human body (finger tip, earlobe, and inner lip) were recorded by using a fiber optic probe. The spectra were collected over the spectral range 1100~1740 nm. Partial least squares regression (PLSR) was applied for the calibration and validation for the determination of blood glucose. The calibration model from earlobe spectra presented better results, showing good correlation with a glucose oxidase method which is a mostly used standard method. This model predicted the glucose concentration for validation set with a SEP of 33 mg/Dl. This study indicated the feasibility for non-invasive monitoring of blood glucose by a portable near ifrared system.
국내 시판 중인 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 탈착 및 저장성 평가 연구
이나루 ( Na Roo Lee ),이광용 ( Gwang Yong Yi ) 한국산업보건학회 2014 한국산업보건학회지 Vol.24 No.3
Purpose: This study was conducted to evaluate desorption efficiency and storage stability on activated carbon acquired form domestic market. Materials: Mixture of acetone, benzene, normal hexane and toluene was injected on four types of charcoal 100 ㎎. After overnight, charcoal was desorbed by carbon disulfide 1 ㎖ and analyzed by gas chromatography with flame ionization detector. Results: Desorption efficiency of benzene, normal hexane and toluene in charcoal tubes were 95% ∼ 105%. But desorption efficiency of acetone in charcoal tubes was below 75% and different from types of charcoal. The more injected amount of acetone on charcoal showed higher desorption efficiency. Acetone injected on charcoal tubes migrated from front section into back section after 10 days storage at room temperature. Conclusions: Desorption efficiency and storage stability of activated carbon acquired from domestic market was good for benzene, normal hexane and toluene. The activated carbon acquired from domestic market has ability to be used as sampling media.