RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Comparison of the Pullout Strength of Different Pedicle Screw Designs and Augmentation Techniques in an Osteoporotic Bone Model

        Gorkem Kiyak,Tevfik Balikci,Ahmed Majid Heydar,Murat Bezer 대한척추외과학회 2018 Asian Spine Journal Vol.12 No.1

        Study Design: Mechanical study. Purpose: To compare the pullout strength of different screw designs and augmentation techniques in an osteoporotic bone model. Overview of Literature: Adequate bone screw pullout strength is a common problem among osteoporotic patients. Various screw designs and augmentation techniques have been developed to improve the biomechanical characteristics of the bone–screw interface. Methods: Polyurethane blocks were used to mimic human osteoporotic cancellous bone, and six different screw designs were tested. Five standard and expandable screws without augmentation, eight expandable screws with polymethylmethacrylate (PMMA) or calcium phosphate augmentation, and distal cannulated screws with PMMA and calcium phosphate augmentation were tested. Mechanical tests were performed on 10 unused new screws of each group. Screws with or without augmentation were inserted in a block that was held in a fixture frame, and a longitudinal extraction force was applied to the screw head at a loading rate of 5 mm/ min. Maximum load was recorded in a load displacement curve. Results: The peak pullout force of all tested screws with or without augmentation was significantly greater than that of the standard pedicle screw. The greatest pullout force was observed with 40-mm expandable pedicle screws with four fins and PMMA augmentation. Augmented distal cannulated screws did not have a greater peak pullout force than nonaugmented expandable screws. PMMA augmentation provided a greater peak pullout force than calcium phosphate augmentation. Conclusions: Expandable pedicle screws had greater peak pullout forces than standard pedicle screws and had the advantage of augmentation with either PMMA or calcium phosphate cement. Although calcium phosphate cement is biodegradable, osteoconductive, and nonexothermic, PMMA provided a significantly greater peak pullout force. PMMA-augmented expandable 40-mm four-fin pedicle screws had the greatest peak pullout force.

      • KCI등재

        Mid-length Pedicle Screws in Posterior Instrumentation of Scoliosis

        Tevfik Balikci,Görkem Kıyak,Ahmed Majid Heydar,Motasim Khalid Bawaneh,Murat Bezer 대한척추외과학회 2019 Asian Spine Journal Vol.13 No.5

        Study Design: Prospective analysis of collected data. Purpose: We determine the need for the use of mid-length pedicle screws (screws with 2.5-mm long increments) during posterior spinal instrumentation. Overview of Literature: Many biomechanical studies have been performed showing that increasing the pedicle screw insertion depth provides an improved resistance to pullout, cyclic loading, and derotational forces, but no intermediate length screws were used. Methods: We prospectively evaluated 120 patients who received posterior segmental instrumentation for structural scoliosis. Preoperatively, 91.44-cm long cassette anteroposterior (AP), lateral, and AP bending radiographs and multiplanar computed tomography were performed in all patients routinely. We measured chord length to determine the maximum probable screw length of all vertebrae. All pedicle screws were attempted to be placed as long as possible. The main intention was at least to engage the subcortical bone of the anterior vertebral cortex. Especially in the apical region, the screws were attempted to be inserted bicortically. The length, level, region, and side of each screw were recorded. Screws with 5-mm increments were called standard length screws (SLS), and middle-sized screws with 2.5-mm increments were called mid-length screws (MLS). Results: Of 2,846 pedicle screws inserted, 1,575 (55.4%) were SLS and 1,271 (44.6%) were MLS, demonstrating a need for MLS in scoliosis surgery (p<0.05). The need for MLS increased significantly in the thoracic region, apical vertebrae, and convex side (p<0.05). Conclusions: If anterior cortex engagement or longer placement of pedicle screws is intended during scoliosis surgery, for safer placement, screws with 2.5-mm increments should be available in posterior instrumentation systems.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼