http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
The Impact of Intrapericardial versus Intrapleural HeartMate 3 Pump Placement on Clinical Outcomes
Michael Salna,Yuming Ning,Paul Kurlansky,Melana Yuzefpolskaya,Paolo C. Colombo,Yoshifumi Naka,Koji Takeda 대한심장혈관흉부외과학회 2022 Journal of Chest Surgery (J Chest Surg) Vol.55 No.3
Background: The integrated design of the HeartMate 3 (Abbott Laboratories, Chicago, IL, USA) affords flexibility to place the pump within the pericardium or thoracic cavity. We sought to determine whether the presence of a left ventricular assist device (LVAD) in either location has a meaningful impact on overall patient outcomes. Methods: A retrospective cohort study was conducted of all 165 patients who received a HeartMate 3 LVAD via a median sternotomy from November 2014 to August 2019 at our center. Based on operative reports and imaging, patients were divided into intrapleural (n=81) and intrapericardial (n=84) cohorts. The primary outcome of interest was in-hospital mortality, while secondary outcomes included postoperative complications, cumulative readmission incidence, and 3-year survival. Results: There were no significant between-group differences in baseline demographics, risk factors, or preoperative hemodynamics. The overall in-hospital mortality rate was 6%, with no significant difference between the cohorts (9% vs. 4%, p=0.20). There were no significant differences in the postoperative rates of right ventricular failure, kidney failure requiring hemodialysis, stroke, tracheostomy, or arrhythmias. Over 3 years, despite similar mortality rates, intrapleural patients had significantly more readmissions (n=180 vs. n=117, p<0.01) with the most common reason being infection (n=68/165), predominantly unrelated to the device. Intrapleural patients had significantly more infection-related readmissions, predominantly driven by non-ventricular assist device-related infections (p=0.02), with 41% of these due to respiratory infections compared with 28% of intrapericardial patients. Conclusion: Compared with intrapericardial placement, insertion of an intrapleural HM3 may be associated with a higher incidence of readmission, especially due to respiratory infection.
COR-KNOT-Induced Leaflet Perforation: How It Happens and How to Prevent It: A Case Report
Michael Salna,Jack Shanewise,Alex D’Angelo,Isaac George 대한심장혈관흉부외과학회 2024 Journal of Chest Surgery (J Chest Surg) Vol.57 No.1
The COR-KNOT suture fastening device has dramatically improved the efficiency of valve suture fixation. Despite its relative ease of use, there are important considerations in deployment to limit the risk of prosthetic valve injury. Herein, we report a case of iatrogenic aortic bioprosthetic insufficiency caused by poorly positioned COR-KNOTs and outline technical strategies to ensure success.