RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUSKCI등재

        The reliability of tablet computers in depicting maxillofacial radiographic landmarks

        Tadinada, Aditya,Mahdian, Mina,Sheth, Sonam,Chandhoke, Taranpreet K,Gopalakrishna, Aadarsh,Potluri, Anitha,Yadav, Sumit Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.46 No.1

        Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

      • KCI등재

        Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

        Hanadi Sabban,Mina Mahdian,Ajay Dhingra,Alan G. Lurie,Aditya Tadinada 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.2

        Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

      • SCOPUSKCI등재

        Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

        Sabban, Hanadi,Mahdian, Mina,Dhingra, Ajay,Lurie, Alan G.,Tadinada, Aditya Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.45 No.2

        Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

      • KCI등재

        The reliability of tablet computers in depicting maxillofacial radiographic landmarks

        Aditya Tadinada,Mina Mahdian,Sonam Sheth,Taranpreet K Chandhoke,Aadarsh Gopalakrishna,Anitha Potluri,Sumit Yadav 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.3

        Purpose: This study was performed to evaluate the reliability of the identification of anatomical landmarks in panoramic and lateral cephalometric radiographs on a standard medical grade picture archiving communication system (PACS) monitor and a tablet computer (iPad 5). Materials and Methods: A total of 1000 radiographs, including 500 panoramic and 500 lateral cephalometric radiographs, were retrieved from the de-identified dataset of the archive of the Section of Oral and Maxillofacial Radiology of the University Of Connecticut School Of Dental Medicine. Major radiographic anatomical landmarks were independently reviewed by two examiners on both displays. The examiners initially reviewed ten panoramic and ten lateral cephalometric radiographs using each imaging system, in order to verify interoperator agreement in landmark identification. The images were scored on a four-point scale reflecting the diagnostic image quality and exposure level of the images. Results: Statistical analysis showed no significant difference between the two displays regarding the visibility and clarity of the landmarks in either the panoramic or cephalometric radiographs. Conclusion: Tablet computers can reliably show anatomical landmarks in panoramic and lateral cephalometric radiographs.

      • SCOPUSKCI등재

        Radiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two-dimensional and three-dimensional radiographic imaging

        Tadinada, Aditya,Fung, Karen,Thacker, Sejal,Mahdian, Mina,Jadhav, Aniket,Schincaglia, Gian Pietro Korean Academy of Oral and Maxillofacial Radiology 2015 Imaging Science in Dentistry Vol.46 No.1

        Purpose: This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. Materials and Methods: This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach's alpha, and intraobserver reliability was assessed using Cohen's kappa. Results: Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). Conclusion: Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.

      • KCI등재

        Light transmittance of CAD/CAM ceramics with different shades and thicknesses andmicrohardness of the underlying light-cured resin cement

        Zahra Jafari,Homayoon Alaghehmand,Yasaman Samani,Mina Mahdian,Soraya Khafri 대한치과보존학회 2018 Restorative Dentistry & Endodontics Vol.43 No.3

        Objectives: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a 37°C incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (α = 0.05). Results: Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). Conclusion: Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.

      • KCI등재

        radioRadiographic evaluation of the maxillary sinus prior to dental implant therapy: A comparison between two-dimensional and three-dimensional radiographic imaging

        Aditya Tadinada,Karen Fung,Sejal Thacker,Mina Mahdian,Aniket Jadhav,Gian Pietro Schincaglia 대한영상치의학회 2015 Imaging Science in Dentistry Vol.45 No.3

        Purpose: This study was performed to evaluate the diagnostic efficacy of panoramic radiography and cone-beam computed tomography (CBCT) in detecting sinus pathology. Materials and Methods: This study was based on a retrospective evaluation of patients who had undergone both a panoramic radiograph and a CBCT exam. A total of 100 maxillary sinuses were evaluated. Four examiners with various levels of expertise evaluated the images using a five-point scoring system. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic efficacy of the two modalities. The image analysis was repeated twice, with at least two weeks between the evaluation sessions. Interobserver reliability was assessed using Cronbach’s alpha, and intraobserver reliability was assessed using Cohen’s kappa. Results: Maxillary sinus pathology was detected in 72% of the patients. High interobserver and intraobserver reliability were observed for both imaging modalities and among the four examiners. Statistical analyses using ROC curves demonstrated that the CBCT images had a larger area under the curve (0.940) than the panoramic radiographs (0.579). Conclusion: Three-dimensional evaluation of the sinus with CBCT was significantly more reliable in detecting pathology than panoramic imaging.

      • KCI등재

        Light transmittance of CAD/CAM ceramics with different shades and thicknesses and microhardness of the underlying light-cured resin cement

        Jafari, Zahra,Alaghehmand, Homayoon,Samani, Yasaman,Mahdian, Mina,Khafri, Soraya The Korean Academy of Conservative Dentistry 2018 Restorative Dentistry & Endodontics Vol.43 No.3

        Objectives: The aim of this in vitro study was to evaluate the effects of the thickness and shade of 3 types of computer-aided design/computer-aided manufacturing (CAD/CAM) materials. Materials and Methods: A total of 120 specimens of 2 shades (A1 and A3) and 2 thicknesses (1 and 2 mm) were fabricated using VITA Mark II (VM; VITA Zahnfabrik), IPS e.max CAD (IE; IvoclarVivadent), and VITA Suprinity (VS; VITA Zahnfabrik) (n = 10 per subgroup). The amount of light transmission through the ceramic specimens was measured by a radiometer (Optilux, Kerr). Light-cured resin cement samples (Choice 2, Bisco) were fabricated in a Teflon mold and activated through the various ceramics with different shades and thicknesses using an LED unit (Bluephase, IvoclarVivadent). In the control group, the resin cement sample was directly light-cured without any ceramic. Vickers microhardness indentations were made on the resin surfaces (KoopaPazhoohesh) after 24 hours of dark storage in a $37^{\circ}C$ incubator. Data were analyzed using analysis of variance followed by the Tukey post hoc test (${\alpha}=0.05$). Results: Ceramic thickness and shade had significant effects on light transmission and the microhardness of all specimens (p < 0.05). The mean values of light transmittance and microhardness of the resin cement in the VM group were significantly higher than those observed in the IE and VS groups. The lowest microhardness was observed in the VS group, due to the lowest level of light transmission (p < 0.05). Conclusion: Greater thickness and darker shades of the 3 types of CAD/CAM ceramics significantly decreased the microhardness of the underlying resin cement.

      • SCOPUSKCI등재

        An unusual presentation of osteoblastoma of the maxilla: A case report

        Lim, Joonbum,Hinchy, Nicole,Odingo, Nora,Colosi, Dan,Mahdian, Mina Korean Academy of Oral and Maxillofacial Radiology 2021 Imaging Science in Dentistry Vol.51 No.-

        This report presents a rare case of maxillary osteoblastoma in a 17-year-old female. The patient presented with dull pain and facial asymmetry inferior to the left zygoma. An intraoral examination found a painless swelling on the buccal gingival tissue in the left posterior maxilla. Panoramic radiographs and multidetector computed tomographic images revealed an ill-defined, non-corticated, mixed attenuating entity of osseous density located within the left posterior maxilla apical to the left maxillary molars. The entity exhibited a heterogeneous internal structure with a fine granular appearance, and the periphery showed a partial hypo-attenuating rim along the antero-medial aspect. Expansion of the left posterior maxilla accompanied with displacement of the left maxillary sinus floor was noted. External root resorption of the first and second molars was noted, as well as postero-superior displacement of the third molar. The histopathologic diagnosis of the biopsy was osteoblastoma. Complete excision of the tumor was performed.

      • KCI등재

        An unusual presentation of osteoblastoma of the maxilla: A case report

        Lim Joonbum,Hinchy Nicole,Odingo Nora,Colosi Dan,Mahdian Mina 대한영상치의학회 2021 Imaging Science in Dentistry Vol.51 No.4

        This report presents a rare case of maxillary osteoblastoma in a 17-year-old female. The patient presented with dull pain and facial asymmetry inferior to the left zygoma. An intraoral examination found a painless swelling on the buccal gingival tissue in the left posterior maxilla. Panoramic radiographs and multidetector computed tomographic images revealed an ill-defined, non-corticated, mixed attenuating entity of osseous density located within the left posterior maxilla apical to the left maxillary molars. The entity exhibited a heterogeneous internal structure with a fine granular appearance, and the periphery showed a partial hypo-attenuating rim along the antero-medial aspect. Expansion of the left posterior maxilla accompanied with displacement of the left maxillary sinus floor was noted. External root resorption of the first and second molars was noted, as well as postero-superior displacement of the third molar. The histopathologic diagnosis of the biopsy was osteoblastoma. Complete excision of the tumor was performed.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼