RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Study on Treatment Planning for the Prostate in Proton Therapy with Oxygen Enhancement Ratio Effect

        Yoo Seung Hoon,Geng Hui,Lam Wai Wang,Kong Chi Wah,Yang Bin,Chiu Tin Lok,Wu Po Man,Cheung Kin Yin,Yu Siu Ki,Shin Dongho,Min Byung Jun 한국물리학회 2020 THE JOURNAL OF THE KOREAN PHYSICAL SOCIETY Vol.77 No.7

        The purpose of this study was to investigate the oxygen enhancement ratio (OER) effects on treatment planning for a hypoxic prostate tumor with proton scanning beams. Two different OER-based dose calculation models (the average model and the voxel model) were investigated by using hypoxic tumor models in this simulation study. For the hypoxic tumor model, an oxygen distribution with a range of 2.4-9.4 mmHg was used according to the clinical data. The results given by the average model and the voxel model were compared for 50% and 90% tumor control probabilities with variations in the hypoxic tumor volume and fractionation. Comparison between the treatment plans with OER-based higher predicted dose and with the conventional prescription dose was conducted to investigate the organ-at-risk (OAR) doses for the prostate case. The average model showed a higher calculated dose than the voxel model. The voxel model with a 50% control probability showed good agreement with the current prescription dose. The OER values of the average model ranged from 1.05 to 1.25, which were applied to the whole tumor volume in treatment planning. The voxel-model-based OERs were higher (1.50-1.75) than those of average model, and these OERs should be applied only for the hypoxic boost region. Regarding treatment plans, the doses of the rectum and the bladder were reduced to the tolerable range V80Gy (volume receiving equal to or greater than 80Gy) < 15% and V75Gy (volume receiving equal to or greater than 75Gy) < 15% respectively after an optimization, but the maximum dose to femoral heads was higher than 50 Gy. In conclusion, we investigated the possible ranges of the OER (1.3-1.8) for proton-beam treatment of prostate cases. A dose escalation of up to about 1.8 times can be applied for the small hypoxic region. This result, which was obtained using a model study, should be verified through clinical experiment.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼