        풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구

        Ryu, Hocheol,Kim, Doohyun 한국재난정보학회 2015 한국재난정보학회 논문집 Vol.11 No.2

        The heat detector detects heat in the fire and is an important core element of the automatic fire alarm system used generally for every fire prevention objects. The heat detector is distinguished in spot type and spread type and in spot type, there are differential and thermistor types. These heat detectors give a great influence on the loss of people and property according to the sensitivity of response such as operation time and operation temperature in actual fire and in overseas people apply it for the development of products that can be operated in the early stage of fire including certification, quality management, and comparison standard by introducing response time index through the theory of heat balance that considers the heat loss and ventilation tests. In Korea, the response time index is introduced and used in the head of sprinkler products, but it is not applied to the heat detector at present. It is necessary to introduce the response time index that shows the sensitivity of response of the heat detector the installation standard for the heat detector that the response time index is applied should be different according to the fire weight, danger degree of fire, and shape of buildings. Through this study, it tries to help reduce lives and property of people through the swift warning by installing detectors suitable for the building structure. 열감지기는 화재시 발생되는 열을 감지하는 것으로 모든 소방대상물에 일반적으로 사용되는 자동화재탐지설비의 중요한 핵심 요소이다. 열감지기는 스포트(spot)형과 분포형으로 구분되며, 스포트형에는 차동식과 정온식이 있다. 이러한 열감지기는 실제 화재시 작동시간 및 작동온도 등 반응의 민감도에 따라 인명과 재산 손실에 큰 영향을 준다. 국내에서는 스프링클러 헤드제품에 응답시간지수를 도입하여 사용하고 있으나, 열감지기에 대해서는 현재 적용이 되어지지 않고 있으며, 반응의 민감도를 표시하는 응답시간지수의 도입이 필수적으로 본 연구에서는 국내 생산된 정온식 스포트형 열감지기와 다이아프램형 및 반도체 형식의 차동식 스포트형 열감지기에 대하여 풍동실험 및 화재실험을 통하여 응답시간지수, 작동시간, 작동온도 등에 대하여 연구하였다. 응답시간지수를 적용한 열감지기를 설치하여 신속한 경보로 인한 국민의 생명과 재산손실을 줄이는데 도움을 주고자 한다.

      • KCI등재

        풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구

        Hocheol Ryu,Doohyun Kim 한국재난정보학회 2015 한국재난정보학회 논문집 Vol.11 No.2

        열감지기는 화재시 발생되는 열을 감지하는 것으로 모든 소방대상물에 일반적으로 사용 되는 자동화재탐지설비의 중요한 핵심 요소이다. 열감지기는 스포트(spot)형과 분포형으로 구분되며, 스포트형에는 차동식과 정온식이 있다. 이러한 열감지기는 실제 화재시 작동시 간 및 작동온도 등 반응의 민감도에 따라 인명과 재산 손실에 큰 영향을 준다. 국내에서는 스프링클러 헤드제품에 응답시간지수를 도입하여 사용하고 있으나, 열감지기에 대해서는 현재 적용이 되어지지 않고 있으며, 반응의 민감도를 표시하는 응답시간지수의 도입이 필 수적으로 본 연구에서는 국내 생산된 정온식 스포트형 열감지기와 다이아프램형 및 반도체 형식의 차동식 스포트형 열감지기에 대하여 풍동실험 및 화재실험을 통하여 응답시간지수, 작동시간, 작동온도 등에 대하여 연구하였다. 응답시간지수를 적용한 열감지기를 설치하여 신속한 경보로 인한 국민의 생명과 재산손실을 줄이는데 도움을 주고자 한다. The heat detector detects heat in the fire and is an important core element of the automatic fire alarm system used generally for every fire prevention objects. The heat detector is distinguished in spot type and spread type and in spot type, there are differential and thermistor types. These heat detectors give a great influence on the loss of people and property according to the sensitivity of response such as operation time and operation temperature in actual fire and in overseas people apply it for the development of products that can be operated in the early stage of fire including certification, quality management, and comparison standard by introducing response time index through the theory of heat balance that considers the heat loss and ventilation tests. In Korea, the response time index is introduced and used in the head of sprinkler products, but it is not applied to the heat detector at present. It is necessary to introduce the response time index that shows the sensitivity of response of the heat detector the installation standard for the heat detector that the response time index is applied should be different according to the fire weight, danger degree of fire, and shape of buildings. Through this study, it tries to help reduce lives and property of people through the swift warning by installing detectors suitable for the building structure.

      • KCI등재

        실내화재에서의 열감지기 동작특성 분석

        Ryu, Hocheol 한국재난정보학회 2014 한국재난정보학회 논문집 Vol.10 No.4

        소방대상물에서의 경보설비는 실내에 있는 사람들에게 화재를 최초로 알려주는 설비로써, 보다 많은 사람들을 대피시킬 수 있도록 하는 매우 중요한 역할을 한다. 이에 자동화재탐지설비와 같은 경보설비의 최초동작을 빠르게 하기 위한 연구가 필요하다. 이러한 자동화재탐지설비에서 감지기의 동작은 설치위치와 화원의 위치에 따른 영향을 가장 많이 받는다. 그럼에도 불구하고 국내의 감지기 설치 기준은 설치 위치와 화원의 위치는 중시하지 않고 면적과 높이에 따른 화재감지기 설치에 대한 사항만을 규정하고 있다. 따라서 본 연구에서는 실내에 열감지기와 보를 설치하고, 일반적인 화재를 가정하여 5 개소의 화원을 발생시켜 설치된 감지기의 동작시간을 측정하였고, 감지기의 설치위치와 화원의 위치를 고려한 화재실험을 통하여 열감지기의 동작특성을 분석한 것으로 다음과 같은 결론을 얻었다. 열감지기는 벽면에 근접하게 설치된 감지기에서 작동지연현상이 보였으며, 벽면에서 적어도 22cm 이상 이격해서 설치하여야 한다. 화원이 보 외측에 존재할 때 감지기는 보에서 55cm 이격한 거리에서 동작이 가장 빨랐다. 또한 화원에 근접한 감지기와 가장 늦게 동작한 감지기의 동작시간의 차이는 피난거리로 환산하였을 때 최대 115 m 의 피난거리가 확보되는 것으로 나타났다. 이를 통하여 적합한 위치와 적응성을 고려한 감지기의 선택은 피난개시 시간을 최소화시켜 줄 수 있는 것을 확인하였다. The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.

      • KCI등재

        실내화재에서의 열감지기 동작특성 분석

        Hocheol Ryu 한국재난정보학회 2014 한국재난정보학회 논문집 Vol.10 No.4

        소방대상물에서의 경보설비는 실내에 있는 사람들에게 화재를 최초로 알려주는 설비로써, 보 다 많은 사람들을 대피시킬 수 있도록 하는 매우 중요한 역할을 한다. 이에 자동화재탐지설비 와 같은 경보설비의 최초동작을 빠르게 하기 위한 연구가 필요하다. 이러한 자동화재탐지설비 에서 감지기의 동작은 설치위치와 화원의 위치에 따른 영향을 가장 많이 받는다. 그럼에도 불 구하고 국내의 감지기 설치 기준은 설치 위치와 화원의 위치는 중시하지 않고 면적과 높이에 따른 화재감지기 설치에 대한 사항만을 규정하고 있다. 따라서 본 연구에서는 실내에 열감지 기와 보를 설치하고, 일반적인 화재를 가정하여 5 개소의 화원을 발생시켜 설치된 감지기의 동 작시간을 측정하였고, 감지기의 설치위치와 화원의 위치를 고려한 화재실험을 통하여 열감지 기의 동작특성을 분석한 것으로 다음과 같은 결론을 얻었다. 열감지기는 벽면에 근접하게 설 치된 감지기에서 작동지연현상이 보였으며, 벽면에서 적어도 22cm 이상 이격해서 설치하여야 한다. 화원이 보 외측에 존재할 때 감지기는 보에서 55cm 이격한 거리에서 동작이 가장 빨랐 다. 또한 화원에 근접한 감지기와 가장 늦게 동작한 감지기의 동작시간의 차이는 피난거리로 환산하였을 때 최대 115 m 의 피난거리가 확보되는 것으로 나타났다. 이를 통하여 적합한 위치 와 적응성을 고려한 감지기의 선택은 피난개시 시간을 최소화시켜 줄 수 있는 것을 확인하였다. The first operation of alarm system starts at a detector. And the largest effect is produced on the operation of detector by the fire source position and installation position. Nevertheless, the Korean standard for the installation of detector only specifies matters of fire detector installation according to area and height, without consideration of installation position and fire source position. Therefore, this study carried out a fire test in consideration of detector installation position and fire source position (5 places) in order to minimize casualties owing to the fast operation of fire detector when a fire occurred. Considering that it took the longest time for a detector close to a wall to work in the results of this test, it was possible to find that a minimum clearance to the wall was required.

      • Age-related differences in control of a visuomotor coordination task: a preliminary study

        Ryu, Young Uk,Lee, Kyu-Ho,Lee, Hocheol,Park, Jungsik SOCIETY OF PHYSICAL THERAPY SCIENCE 2016 JOURNAL OF PHYSICAL THERAPY SCIENCE Vol. No.

        <P>[Purpose] The purpose of the current study was to examine age-related differences in control of a perception-action coordination skill. We adapted a visuomotor tracking experiment requiring various coordination patterns between a limb’s motion and an external signal. [Subjects and Methods] A total of 12 subjects (6 elderly and 6 young) voluntarily participated in the study. The experimental session consisted of 3 trials for 3 different relative phase patterns: 0°, 90°, and 180°, defined by the relationship between the online visual feedback of the joystick motion and the white dot signal. [Results] The 0° and 180° tracking patterns were stable compared with the 90° tracking pattern for both age groups. The present results also showed that the elderly subjects were less stable than were young subjects for all tracking patterns. [Conclusion] The intrinsic coordination dynamics predicted by the Haken-Kelso-Bunz (HKB) mathematical model did not change with age, whereas utilization of visual feedback information declined overall. Further research is needed regarding methods for increasing utilization of visual feedback information from the perspective of rehabilitation.</P>

      • Alcoholic and non-alcoholic fatty liver disease and associations with coronary artery calcification: evidence from the Kangbuk Samsung Health Study

        Chang, Yoosoo,Ryu, Seungho,Sung, Ki-Chul,Cho, Yong Kyun,Sung, Eunju,Kim, Han-Na,Jung, Hyun-Suk,Yun, Kyung Eun,Ahn, Jiin,Shin, Hocheol,Wild, Sarah Helen,Byrne, Christopher D BMJ Publishing Group Ltd 2019 Gut: journal of the British Society of Gastroenter Vol.68 No.9

        <P><B>Objective</B></P><P>Recent evidence suggests that alcoholic fatty liver disease (AFLD) and non-alcoholic fatty liver disease (NAFLD) may differentially affect risk of cardiovascular mortality. To investigate whether early liver disease due to AFLD or NAFLD have similar or dissimilar effects on risk of early coronary artery atherosclerosis, we have investigated the associations between AFLD and NAFLD and coronary artery calcium (CAC).</P><P><B>Design</B></P><P>A cross-sectional study was performed in 105 328 Korean adults who attended a health check-up programme. CAC score was assessed using CT, daily alcohol intake was recorded as grams/day and liver fat by ultrasound. Logistic regression model was used to calculate ORs with 95% CIs for prevalent CAC.</P><P><B>Results</B></P><P>Both NAFLD and AFLD were positively associated with CAC score. After adjusting for potential confounders, multivariable-adjusted OR (95% CIs) for CAC >0 comparing NAFLD and AFLD to the reference (absence of both excessive alcohol use and fatty liver disease) were 1.10 (95% CI 1.05 to 1.16) and 1.20 (95% CI 1.11 to 1.30), respectively. In post hoc analysis, OR (95% CI) for detectable CAC comparing AFLD to NAFLD was 1.09 (95% CI 1.01 to 1.17). Associations of NAFLD and AFLD with CAC scores were similar in both non-obese and obese individuals without significant interaction by obesity (p for interaction=0.088). After adjusting for homeostasis model assessment of insulin resistance and high-sensitivity C reactive protein, the associations between fatty liver disease and CAC scores remained statistically significant.</P><P><B>Conclusion</B></P><P>In this large sample of young and middle-aged individuals, early liver disease due to NAFLD and AFLD were both significantly associated with the presence of coronary artery calcification.</P>

      • 화원의 특성이 화재감지기의 응답에 주는 영향

        심우철 ( Woochul Shim ),류호철 ( Hocheol Ryu ),이주혁 ( Joohyuck Lee ),신창섭 ( Changsub Shin ) 충북대학교 산업과학기술연구소 2016 산업과학기술연구 논문집 Vol.30 No.1

        Before occupants inhale fatal amount of toxic gas, evacuation should be started in case of indoor fire. To trigger an alarm, fire should be detected by fire detectors. In this study, to measure the response time of various fire detectors, four kinds of combustibles were experimented. The response times of a differential temperature fire detector, a smoke detector and a constant temperature type fire detector were analyzed by carrying out fire experiments of dry wood, wet wood, rubber and heptane. The response time of a differential temperature fire detector was faster than a fixed temperature detector for wood fire. In case of rubber fire, a smoke detector was effective than any other detectors and the variation of response time of a differential detector for heptane fire was very small.

      • A Highly Linear, AEC-Q100 Compliant Signal Conditioning IC for Automotive Piezo-Resistive Pressure Sensors

        Lee, DongSoo,Cho, SungHun,Ryu, Hocheol,Pu, YoungGun,Yoo, Sang-Sun,Lee, Minjae,Hwang, Keum Cheol,Youngoo, Youngoo Yang,Lee, Kang-Yoon IEEE 2018 IEEE transactions on industrial electronics Vol.65 No.9

        <P>In this paper, the design of a signal conditioning analog front-end (AFE) IC for an automotive piezo-resistive type pressure sensor is presented. To improve the pressure-sensing accuracy and compensate for variations in the pressure sensor and signal conditioning IC, gauge factor calibration, digital automatic offset, and gain calibration are proposed and implemented with low power consumption. By using a high-resolution analog-to-digital converter and digital-to-analog converter, the digital automatic calibration circuit can guarantee linearity of output voltage with respect to pressure to within 0.5%. As the analog signal is converted to a digital signal, accuracy in the AFE IC improves. To improve the reliability in the automotive environment, over-voltage and reverse-voltage protection circuits are integrated with the electrostatic discharge protection circuit. Also, electromagnetic interference is reduced by using the proposed spread spectrum clock generator.</P> <P>The proposed design is implemented using 2P4M 0.35 μm CMOS technology with an active area of 1.94 mm × 1.94 mm. Full output ranges from 0.5 to 4.5 V. The ratiometricity error is within ±0.25% when the supply voltage is changed by ±10%. Current consumption is 4.7 mA from a 5 V supply. The output accuracy is within ±0.5% with respect to the PVT variations.</P>