http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Application of Fault Tree Analysis in Supervising Critical Control Points of Spray Dryer
Bao Han 보안공학연구지원센터 2014 International Journal of Control and Automation Vol.7 No.12
FAT (Fault tree analysis) of drying processing was performed to investigate the causes for faults in equipments management. The causes were deductively identified as the events causing every possible hazard by constructing a fault tree. The fault tree was constructed in a hierarchical structure with a single top event fault, four intermediate event faults, and eight basic event faults connected by a Boolean AND gate, or an OR gate. Qualitative analysis of the fault tree yielded minimal cut sets, structural importance, and common cause vulnerability. Quantitative analysis of the fault tree yielded simulation of final top event fault, cut set importance, item importance, and sensitivity. Basically, these factors were a measure to represent the priority order of the basic events causing the top event. The priority order of these basic events was consistent between qualitative and quantitative analysis. Therefore, the FTA, with qualitative and quantitative analysis, was a good alternative approach to fault analysis in spray dryer, and it also could be further used to the analysis of critical control points..
Han, Bao-Lin,Xu, Xiang-Ying,Zhang, Chun-Zhi,Wu, Jian-Juan,Han, Chun-Feng,Wang, Hui,Wang, Xuan,Wang, Guang-Shun,Yang, Shu-Juan,Xie, Yao Asian Pacific Journal of Cancer Prevention 2012 Asian Pacific journal of cancer prevention Vol.13 No.6
Objective: To conduct a meta-analysis to investigate the value of EBV DNA in diagnosis of nasopharyngeal cancer (NPC) in Asian populations, and provide important evidence for screening. Methods: Prospective or respective case-control or cohort studies regarding the detection role of EBV DNA for NPC were included in our study. We conducted a comprehensive literature search in PubMed, EMBASE, and the Chinese Biomedical Database (CBM database between January 1980 and March 2012. Results: A total of 18 studies with 1492 NPC cases and 2641 health controls were included. Almost of the included studies were conducted in China, and only one other conducted in Thailand. The overall results demonstrated that the pooled sensitivity, specificity, positive likelihood (+LR) and negative likelihood (-LR) were 0.73 (0.71-0.75), 0.89 (0.88-0.90), 8.84 (5.65-13.84) and 0.19(0.11-0.32), respectively. The overall EBV DNA detection showed the largest area of 0.932 under the summary receiver operator curve (SROC). The accuracy of detection by plasma for NPC (0.86) was higher than in serum (0.81), with largest areas under the SROC of 0.97 and 0.91, respectively. Conclusion: Our results demonstrated the EBV DNA detection in plasma or serum has high sensitivity and specificity in diagnosis of NPC, especially in Chinese populations with a high risk of cancer.
Induction of Apoptosis by IGFBP3 Overexpression in Hepatocellular Carcinoma Cells
Han, Jian-Jun,Xue, De-Wen,Han, Qiu-Rong,Liang, Xiao-Hong,Xie, Li,Li, Sheng,Wu, Hui-Yong,Song, Bao Asian Pacific Journal of Cancer Prevention 2014 Asian Pacific journal of cancer prevention Vol.15 No.23
Background: The insulin-like growth factor (IGF) system comprises a group of proteins that play key roles in regulating cell growth, differentiation, and apoptosis in a variety of cellular systems. The aim of this study was to investigate the role of insulin-like growth factor binding protein 3 (IGFBP3) in hepatocellular carcinoma. Materials and Methods: Expression of IGF2, IGFBP3, and PTEN was analyzed by qRT-PCR. Lentivirus vectors were used to overexpress IGFBP3 in hepatocellular carcinoma cell (HCC) lines. The effect of IGFBP3 on proliferation was investigated by MTT and colony formation assays. Results: Expression of IGF2, IGFBP3, and PTEN in several HCC cell lines was lower than in normal cell lines. After 5-aza-2'-deoxycytidine/trichostatin A treatment, significant demethylation of the promoter region of IGFBP3 was observed in HCC cells. Overexpression of IGFBP3 induced apoptosis and reduced colony formation in HUH7 cells. Conclusions: Expression of IGF2, IGFBP3, and PTEN in several HCC cell lines was lower than in normal cell lines. After 5-aza-2'-deoxycytidine/trichostatin A treatment, significant demethylation of the promoter region of IGFBP3 was observed in HCC cells. Overexpression of IGFBP3 induced apoptosis and reduced colony formation in HUH7 cells.
DISPERSION OF CARBON NANOFIBERS IN AQUEOUS SOLUTION
BAO-MIN WANG,YUAN ZHANG,ZHI-QIANG GUO,YU HAN,HAI-NAN MA 성균관대학교(자연과학캠퍼스) 성균나노과학기술원 2012 NANO Vol.7 No.6
Carbon nano¯bers (CNFs) were puri¯ed by the method of heat treating, and stable homogeneous suspensions of heat-treated CNFs were prepared by using methylcellulose (MC) as a surfactant. The heat-treated CNFs were characterized by di®erential thermal analysis (DTA) and thermogravimetry analysis (TGA), and the sonication-driven dispersion of CNFs in aqueous solution was investigated by measuring ultraviolet absorbency (UV absorbency), zeta potential, adsorption isotherm of MC on CNFs and surface tension of CNF suspensions. In these CNF suspensions, the zeta potentials of CNFs progressively increase with increasing MC concentration, and change from ?15.4?0 mV. The surface tension of CNF suspensions decrease from 38.87mN/m to 36.54mN/m. The adsorption isotherm of MC on CNFs shows an adsorption platform (namely \L" style), and the adsorption isotherm reaches the saturation plateau at MC concentration of about 0.4 g/L. All results show that the optimum concentration ratio of MC to CNFs is 2:1 for dispersion.
Stability Analysis of Closely Star-battened Member of Transmission Tower
Han Jun-ke,Zhang Chun-lei,Li Zhen-bao,Wang Xu-ming 한국강구조학회 2017 International Journal of Steel Structures Vol.17 No.3
Stability of the closely star-battened member of a power transmission tower were researched in this paper, a theoretical analysis was conducted for the buckling mode of the closely star-battened member by different plate batten arrangements. The analytical method of the buckling capacity on the closely star-battened member was proposed here considering an arrangement type of the plate batten and they are compared with the results of a full-scale test. The conclusions are follows: the flexuraltorsional buckling did not happened for the closely star-battened member; the flexural buckling need to be calculated only after the strength reduction factor was considered; the stability-bearing capacity of the closely star-battened member of the line-shape type batten is slightly less than that of the cross-shape type batten; the stability-bearing capacity of the closely star-battened member can be improved when the number of bolts in the plate batten increases in a suitable extent; and the stability-bearing capacity calculated and test results agree well with each other when the stability-bearing capacity analytical method of the closely star-battened member was used to analyze the full-scale test tower. The experimental results show the calculation method is reasonable.
Han Bin,Zhu Xiaoliang,Yang Bao-Wen,Liu Aiguo,Xi Yanyan,Liu Lei,Liu Shenghui,Huang Junlin 한국원자력학회 2023 Nuclear Engineering and Technology Vol.55 No.10
Mixing Vane Grid (MVG) is one of the most important structures in fuel assembly due to its high performance in mixing the coolant and ultimately increasing Critical Heat Flux (CHF), which avoids the temperature rising suddenly of fuel rods. To evaluate the mixing performance of the MVG, a Total Diffusion Coefficient (TDC) mixing coefficient is defined in the subchannel analysis code. Conventionally, the TDC of the spacer grid is obtained from the combination of experiments and subchannel analysis. However, the processing of obtaining and determine a reasonable TDC is much challenging, it is affected by boundary conditions and MVG geometries. In is difficult to perform all the large and costing rod bundle tests. In this paper, the CFD method was applied in TDC analysis. A typical 5 5 MVG was simulated and validated to estimate the mixing performance of the MVG. The subchannel code was used to calculate the TDC. Firstly, the CFD method was validated from the aspect of pressure drop and lateral temperature distribution in the subchannels. Then the effect of boundary conditions including the inlet temperature, inlet velocities, heat flux ratio between hot and cold rods and the arrangement of hot and cold rods on MVG mixing and TDC were studied. The geometric effects on mixing are also carried out in this paper. The effect of vane pattern on mixing was investigated to determine which one is the best to represent the grid's mixing performance.