RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCIESCOPUS

        Effect of building volume and opening size on fluctuating internal pressures

        Ginger, John D.,Holmes, John D.,Kopp, Gregory A. Techno-Press 2008 Wind and Structures, An International Journal (WAS Vol.11 No.5

        This paper considers internal pressure fluctuations for a range of building volumes and dominant wall opening areas. The study recognizes that the air flow in and out of the dominant opening in the envelope generates Helmholtz resonance, which can amplify the internal pressure fluctuations compared to the external pressure, at the opening. Numerical methods were used to estimate fluctuating standard deviation and peak (i.e. design) internal pressures from full-scale measured external pressures. The ratios of standard deviation and peak internal pressures to the external pressures at a dominant windward wall opening of area, AW are presented in terms of the non-dimensional opening size to volume parameter, $S^*=(a_s/\bar{U}_h)^2(A_W^{3/2}/V_{Ie})$ where $a_s$ is the speed of sound, $\bar{U}_h$ is the mean wind speed at the top of the building and $V_{Ie}$ is the effective internal volume. The standard deviation of internal pressure exceeds the external pressures at the opening, for $S^*$ greater than about 0.75, showing increasing amplification with increasing $S^*$. The peak internal pressure can be expected to exceed the peak external pressure at the opening by 10% to 50%, for $S^*$ greater than about 5. A dominant leeward wall opening also produces similar fluctuating internal pressure characteristics.

      • SCIESCOPUS

        Spatial extrapolation of pressure time series on low buildings using proper orthogonal decomposition

        Chen, Yingzhao,Kopp, Gregory A.,Surry, David Techno-Press 2004 Wind and Structures, An International Journal (WAS Vol.7 No.6

        This paper presents a methodology for spatial extrapolation of wind-induced pressure time series from a corner bay to roof locations on a low building away from the corner through the application of proper orthogonal decomposition (POD). The approach is based on the concept that pressure time series in the far field can be approximated as a linear combination of a series of modes and principal coordinates, where the modes are extracted from the full roof pressure field of an aerodynamically similar building and the principal coordinates are calculated from data at the leading corner bay only. The reliability of the extrapolation for uplift time series in nine bays for a cornering wind direction was examined. It is shown that POD can extrapolate reasonably accurately to bays near the leading corner, given the first three modes, but the extrapolation degrades further from the corner bay as the spatial correlations decrease.

      • SCIESCOPUS

        Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

        Henderson, David J.,Ginger, John D.,Morrison, Murray J.,Kopp, Gregory A. Techno-Press 2009 Wind and Structures, An International Journal (WAS Vol.12 No.4

        Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the 'Low-High-Low' (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and full-scale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a "design" cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the "design" cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The "design" cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour "design" cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

      • KCI등재

        Simulated tropical cyclonic winds for low cycle fatigue loading of steel roofing

        David J. Henderson,John D. Ginger,Murray J. Morrison,Gregory A. Kopp 한국풍공학회 2009 Wind and Structures, An International Journal (WAS Vol.12 No.4

        Low rise building roofs can be subjected to large fluctuating pressures during a tropical cyclone resulting in fatigue failure of cladding. Following the damage to housing in Tropical Cyclone Tracy in Darwin, Australia, the Darwin Area Building Manual (DABM) cyclic loading test criteria, that loaded the cladding for 10000 cycles oscillating from zero to a permissible stress design pressure, and the Experimental Building Station TR440 test of 10200 load cycles which increased in steps to the permissible stress design pressure, were developed for assessing building elements susceptible to low cycle fatigue failure. Recently the ‘Low-High-Low’ (L-H-L) cyclic test for metal roofing was introduced into the Building Code of Australia (2007). Following advances in wind tunnel data acquisition and fullscale wind loading simulators, this paper presents a comparison of wind-induced cladding damage, from a “design” cyclone proposed by Jancauskas, et al. (1994), with current test criteria developed by Mahendran (1995). Wind tunnel data were used to generate the external and net pressure time histories on the roof of a low-rise building during the passage of the “design” cyclone. The peak pressures generated at the windward roof corner for a tributary area representative of a cladding fastener are underestimated by the Australian/New Zealand Wind Actions Standard. The “design” cyclone, with increasing and decreasing wind speeds combined with changes in wind direction, generated increasing then decreasing pressures in a manner similar to that specified in the L-H-L test. However, the L-H-L test underestimated the magnitude and number of large load cycles, but overestimated the number of cycles in the mid ranges. Cladding elements subjected to the L-H-L test showed greater fatigue damage than when experiencing a five hour “design” cyclone containing higher peak pressures. It is evident that the increased fatigue damage was due to the L-H-L test having a large number of load cycles cycling from zero load (R=0) in contrast to that produced during the cyclone.

      • KCI등재

        Effects of wind direction on the flight trajectories of roof sheathing panels under high winds

        Bahareh Kordi,Gabriel Traczuk,Gregory A. Kopp 한국풍공학회 2010 Wind and Structures, An International Journal (WAS Vol.13 No.2

        By using the ‘failure’ model approach, the effects of wind direction on the flight of sheathing panels from the roof of a model house in extreme winds was investigated. A complex relationship between the initial conditions, failure velocities, flight trajectories and speeds was observed. It was found that the local flow field above the roof and in the wake of the house have important effects on the flight of the panels. For example, when the initial panel location is oblique to the wind direction and in the region of separated flow near the roof edge, the panels do not fly from the roof since the resultant aerodynamic forces are small, even though the pressure coefficients at failure are high. For panels that do fly, wake effects from the building are a source of significant variation of flight trajectories and speeds. It was observed that the horizontal velocities of the panels span a range of about 20%-95% of the roof height gust speed at failure. Numerical calculations assuming uniform, smooth flow appear to be useful for determining panel speeds; in particular, using the mean roof height, 3 sec gust speed provides a useful upper bound for determining panel speeds for the configuration examined. However, there are significant challenges for estimating trajectories using this method.

      • SCIESCOPUS

        Effects of wind direction on the flight trajectories of roof sheathing panels under high winds

        Kordi, Bahareh,Traczuk, Gabriel,Kopp, Gregory A. Techno-Press 2010 Wind and Structures, An International Journal (WAS Vol.13 No.2

        By using the 'failure' model approach, the effects of wind direction on the flight of sheathing panels from the roof of a model house in extreme winds was investigated. A complex relationship between the initial conditions, failure velocities, flight trajectories and speeds was observed. It was found that the local flow field above the roof and in the wake of the house have important effects on the flight of the panels. For example, when the initial panel location is oblique to the wind direction and in the region of separated flow near the roof edge, the panels do not fly from the roof since the resultant aerodynamic forces are small, even though the pressure coefficients at failure are high. For panels that do fly, wake effects from the building are a source of significant variation of flight trajectories and speeds. It was observed that the horizontal velocities of the panels span a range of about 20% - 95% of the roof height gust speed at failure. Numerical calculations assuming uniform, smooth flow appear to be useful for determining panel speeds; in particular, using the mean roof height, 3 sec gust speed provides a useful upper bound for determining panel speeds for the configuration examined. However, there are significant challenges for estimating trajectories using this method.

      • KCI등재

        Wind tunnel studies of cantilever traffic signal structures

        Héctor J. Cruzado,Chris Letchford,Gregory A. Kopp 한국풍공학회 2013 Wind and Structures, An International Journal (WAS Vol.16 No.3

        The wind-induced vibrations of the mast arm of cantilever traffic signal structures can lead to the fatigue failure of these structures. Wind tunnel tests were conducted on an aeroelastic model of this type of structure. Results of these experiments indicated that when the signals have backplates, vortex shedding causes large-amplitude vibrations that could lead to fatigue failure. Vibrations caused by galloping were only observed for one particular angle of attack with the signals having backplates. No evidence for galloping,previously thought to be the dominant cause of fatigue failures in these structures, was observed.

      • KCI등재

        Assessment of capacity curves for transmission line towers under wind loading

        S.S. Banik,H.P. Hong,Gregory A. Kopp 한국풍공학회 2010 Wind and Structures, An International Journal (WAS Vol.13 No.1

        The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers. Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.

      • SCIESCOPUS

        Wind tunnel studies of cantilever traffic signal structures

        Cruzado, Hector J.,Letchford, Chris,Kopp, Gregory A. Techno-Press 2013 Wind and Structures, An International Journal (WAS Vol.16 No.3

        The wind-induced vibrations of the mast arm of cantilever traffic signal structures can lead to the fatigue failure of these structures. Wind tunnel tests were conducted on an aeroelastic model of this type of structure. Results of these experiments indicated that when the signals have backplates, vortex shedding causes large-amplitude vibrations that could lead to fatigue failure. Vibrations caused by galloping were only observed for one particular angle of attack with the signals having backplates. No evidence for galloping, previously thought to be the dominant cause of fatigue failures in these structures, was observed.

      • SCIESCOPUS

        Assessment of capacity curves for transmission line towers under wind loading

        Banik, S.S.,Hong, H.P.,Kopp, Gregory A. Techno-Press 2010 Wind and Structures, An International Journal (WAS Vol.13 No.1

        The recommended factored design wind load effects for overhead lattice transmission line towers by codes and standards are evaluated based on the applicable wind load factor, gust response factor and design wind speed. The current factors and design wind speed were developed considering linear elastic responses and selected notional target safety levels. However, information on the nonlinear inelastic responses of such towers under extreme dynamic wind loading, and on the structural capacity curves of the towers in relation to the design capacities, is lacking. The knowledge and assessment of the capacity curve, and its relation to the design strength, is important to evaluate the integrity and reliability of these towers. Such an assessment was performed in the present study, using a nonlinear static pushover (NSP) analysis and incremental dynamic analysis (IDA), both of which are commonly used in earthquake engineering. For the IDA, temporal and spatially varying wind speeds are simulated based on power spectral density and coherence functions. Numerical results show that the structural capacity curves of the tower determined from the NSP analysis depend on the load pattern, and that the curves determined from the nonlinear static pushover analysis are similar to those obtained from IDA.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼