Influence of polymer coating on SFCL recovery under load
Gorbunova, D.A.,Kumarov, D.R.,Scherbakov, V.I.,Sim, Kideok,Hwang, Soon The Korea Institute of Applied Superconductivity a 2019 한국초전도저온공학회논문지 Vol.21 No.4
This paper is a study of recovery under load process of superconducting fault current limiter (SFCL). SFCL consists of five parallel-connected high-temperature superconductor (HTS) tapes additionally stabilized by stainless tape. Previously, HTS was heated by current pulse to simulate a short circuit in a power grid. During the cooling period, the current amplitude decreased to 23% or less of HTS critical current value, which is the simulation of network re-switching. When HTS with a polymer coating is cooled, temperature gradient on thermal insulation layer occurs, that prevents a boiling crisis and improves the heat sink into liquid nitrogen. Two samples are coated with a 30 ㎛ and 50 ㎛ polylactide (PLA) layers, reference sample has no polymer coating on it. Samples with a polymer coating show 3-5 times faster cooling than the reference one.
Influence of polymer coating on SFCL recovery under load
D.A. Gorbunova,D.R. Kumarov,V.I. Scherbakov,Kideok Sim,Soon Hwang 한국초전도.저온공학회 2019 한국초전도저온공학회논문지 Vol.21 No.4
This paper is a study of recovery under load process of superconducting fault current limiter (SFCL). SFCL consists of five parallel-connected high-temperature superconductor (HTS) tapes additionally stabilized by stainless tape. Previously, HTS was heated by current pulse to simulate a short circuit in a power grid. During the cooling period, the current amplitude decreased to 23% or less of HTS critical current value, which is the simulation of network re-switching. When HTS with a polymer coating is cooled, temperature gradient on thermal insulation layer occurs, that prevents a boiling crisis and improves the heat sink into liquid nitrogen. Two samples are coated with a 30 μm and 50 μm polylactide (PLA) layers, reference sample has no polymer coating on it. Samples with a polymer coating show 3-5 times faster cooling than the reference one.
Barlesi, F.,Scherpereel, A.,Gorbunova, V.,Gervais, R.,Vikströ,m, A.,Chouaid, C.,Chella, A.,Kim, J. H.,Ahn, M. J.,Reck, M.,Pazzola, A.,Kim, H. T.,Aerts, J. G,Morando, C.,Loundou, A.,Groen, H. J. M. Oxford University Press 2014 Annals of oncology Vol.25 No.5
<P>The randomized, phase III AVAPERL trial evaluated the safety and efficacy of bevacizumab maintenance with or without pemetrexed in nonsquamous non–small cell lung cancer (nsNSCLC). Progression-free survival (PFS) was significantly prolonged with bevacizumab–pemetrexed. At a median follow-up of 14.8 months, OS events occurred in 58% of all patients. OS was numerically longer with bevacizumab–pemetrexed versus bevacizumab when measured from randomization (17.1 versus 13.2 months, HR, 0.87 [0.63–1.21]; P=0.29). Second-line therapy was administered in 77% and 70% of patients in the bevacizumab and bevacizumab–pemetrexed arms, respectively.</P>