        Development of a methodology for damping of tall buildings motion using TLCD devices

        Diana, Giorgio,Resta, Ferruccio,Sabato, Diego,Tomasini, Gisella Techno-Press 2013 Wind and Structures, An International Journal (WAS Vol.17 No.6

        One of the most common solutions adopted to reduce vibrations of skyscrapers due to wind or earthquake action is to add external damping devices to these structures, such as a TMD (Tuned Mass Damper) or TLCD (Tuned Liquid Column Damper). It is well known that a TLCD device introduces on the structure a nonlinear damping force whose effect decreases when the amplitude of its motion increases. The main objective of this paper is to describe a Hardware-in-the-Loop test able to validate the effectiveness of the TLCD by simulating the real behavior of a tower subjected to the combined action of wind and a TLCD, considering also the nonlinear effects associated with the damping device behavior. Within this test procedure a scaled TLCD physical model represents the hardware component while the building dynamics are reproduced using a numerical model based on a modal approach. Thanks to the Politecnico di Milano wind tunnel, wind forces acting on the building were calculated from the pressure distributions measured on a scale model. In addition, in the first part of the paper, a new method for evaluating the dissipating characteristics of a TLCD based on an energy approach is presented. This new methodology allows direct linking of the TLCD to be directly linked to the increased damping acting on the structure, facilitating the preliminary design of these devices.

      • KCI등재

        Development of a methodology for damping of tall buildings motion using TLCD devices

        Giorgio Diana,Gisella Tomasini,Ferruccio Resta,Diego Sabato 한국풍공학회 2013 Wind and Structures, An International Journal (WAS Vol.17 No.6

        One of the most common solutions adopted to reduce vibrations of skyscrapers due to wind or earthquake action is to add external damping devices to these structures, such as a TMD (Tuned Mass Damper) or TLCD (Tuned Liquid Column Damper). It is well known that a TLCD device introduces on the structure a nonlinear damping force whose effect decreases when the amplitude of its motion increases. The main objective of this paper is to describe a Hardware-in-the-Loop test able to validate the effectiveness of the TLCD by simulating the real behavior of a tower subjected to the combined action of wind and a TLCD, considering also the nonlinear effects associated with the damping device behavior. Within this test procedure a scaled TLCD physical model represents the hardware component while the building dynamics are reproduced using a numerical model based on a modal approach. Thanks to the Politecnico di Milano wind tunnel, wind forces acting on the building were calculated from the pressure distributions measured on a scale model. In addition, in the first part of the paper, a new method for evaluating the dissipating characteristics of a TLCD based on an energy approach is presented. This new methodology allows direct linking of the TLCD to be directly linked to the increased damping acting on the structure, facilitating the preliminary design of these devices.

      • SCIESCOPUS

        A full-range hybrid device for sound reproduction

        Braghin, Francesco,Castelli-Dezza, Francesco,Cinquemani, Simone,Resta, Ferruccio Techno-Press 2013 Smart Structures and Systems, An International Jou Vol.11 No.6

        The paper deals with the design of a device for sound reproduction to be fixed to a supporting surface. The device is made up of two different types of acoustic actuators based on different technologies. This allows to reproduce sound in the range of frequencies from 20 Hz to 20 kHz. The generation of sound at high frequencies is demanded to a magnetostrictive actuator, while a more traditional magnetodynamics actuator is used to generate sound at low frequencies. The coupling between these two actuators leads to a device having small overall dimensions and high performance.

      • KCI등재후보

        A full-range hybrid device for sound reproduction

        Francesco Braghin,Francesco Castelli-Dezza,Simone Cinquemani,Ferruccio Resta 국제구조공학회 2013 Smart Structures and Systems, An International Jou Vol.11 No.6

        The paper deals with the design of a device for sound reproduction to be fixed to a supporting surface. The device is made up of two different types of acoustic actuators based on different technologies. This allows to reproduce sound in the range of frequencies from 20 Hz to 20 kHz. The generation of sound at high frequencies is demanded to a magnetostrictive actuator, while a more traditional magnetodynamics actuator is used to generate sound at low frequencies. The coupling between these two actuators leads to a device having small overall dimensions and high performance.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼