http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Sachdeva Gulshan,Anuradha Parinam,Jain Vaibhav,VenkataTeja Y. T. 대한설비공학회 2024 International Journal of Air-Conditioning and Refr Vol.32 No.1
The performance of an ejector-assisted condenser outlet split dual-evaporator cycle is compared with a conventional dual-evaporator cycle albeit consisting a pressure reducing valve. The cycles do not employ any separator due to its inability to efficiently separate the liquid and the vapor phases. The comparison of both the cycles has been made for the same cooling capacity in low-temperature evaporator and unit flow rate of R134a and R1234yf as refrigerants. The impacts of changing the operating temperatures of evaporator and condenser have been examined in the current investigation. The study reveals that with the increase in temperature of the high-temperature evaporator, the cooling capacity of the high-temperature evaporator yields, while that of the low-temperature evaporator plummets in both the cycles. Further, the compressor work is allayed in the ejector-assisted cycle; thus, the COP is enhanced considerably. The percentage COP improvement over the basic cycle is obtained from 14.7 to 17.53% for the refrigerant R1234yf and from 14.45 to 17.32% for R134a; however, the COP of both the cycles with R12134yf is slightly lower than with R134a. The ejector has been modeled assuming a constant pressure theory. The observed trend indicates that the entrainment ratio is improved with the rise in the temperature of low-temperature evaporator, whereas it is decreased with the rise in the temperature of high-temperature evaporator.
Sachdeva Gulshan,Jaiswar Ajay,Anuradha Parinam,Jain Vaibhav 대한설비공학회 2023 International Journal of Air-Conditioning and Refr Vol.31 No.1
The performance of a dual evaporator cycle using ejector is compared with a conventional cycle employing pressure reducing valve. In both the systems, high temperature evaporator is considered as a flooded evaporator, thus a separator is employed after the high temperature evaporator. However, low temperature evaporator is a kind of conventional dry evaporator. The comparison of both systems, i.e., conventional and ejector assisted, is done for the same cooling capacities and same dryness fraction at the exit of high temperature evaporator with R134a, R152a, and R1234yf refrigerants. The effects of varying the states of refrigerant at the exit of flooded evaporator, and temperatures of both the evaporators and the condenser are analyzed using Engineering Equation Solver. It is found that the compressor work is reduced in both the cycles with the rise in low temperature evaporator temperature; however, a little variation is observed in the total cooling effect. The cooling effect in high temperature evaporator is increased with the increase in dryness fraction at the exit of the high temperature flooded evaporator, but it is decreased in low temperature evaporator.
Kumar Vikas,Sachdeva Gulshan,Tiwari Sandeep,Anuradha Parinam,Jain Vaibhav 대한설비공학회 2021 International Journal Of Air-Conditioning and Refr Vol.29 No.3
A conventional vapor compression refrigeration system (VCRS) cascaded with a heat-assisted ejector refrigeration system (ERS) has been experimentally analyzed. Cascading allows the VCRS to operate at lower condenser temperatures and thus achieve a higher coefficient of performance. In this cascaded system, the condenser of the vapor compression system does not dissipate its heat directly to the evaporator of the ERS; instead, water circulates between the condenser of VCRS and the evaporator of ERS to exchange the heat. Seven ejectors of different geometries have been used in the ERS; however, all the ejectors could not maintain thermal equilibrium at the desired operating conditions. The compressor of the cascaded VCRS consumed 1.3 times less power than the noncascaded VCRS. Furthermore, the cascaded system provided a maximum 87.74% improvement in COP over the noncascaded system for the same operating conditions. The performance of the system remained constant until the critical condenser pressure of the ERS.