http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이경회,정재영 충북대학교 건설기술연구소 1982 建設技術論文集 Vol.1 No.1
The planning objective consists in the increase of the well-being of residents and for the accomplishment of the objective, amenity as well as livability should be met. Thus the future vision should be directed toward the whole environment of the residential area which could satisfy the amenity requirment. The flexible model which designed a super-block of 32 becters with special emphasis given to land-use plan and open space can be a comparative criteria with respect to density, public space and community facilities. On the whole, the model suggests the basic concepts of the vision in the future.
특집 - 건축교육과 인력수급 : 대학원교육의 목표와 영역
이경회 대한건축학회 1988 建築 Vol.32 No.1
우리나라 건축(공)학교육은 제도상에서나 그 내용면에서 전근대적인 체제를 탈피하지 못하고 있다. 학문적 발전 추세와 사회 여건 변화에도 불구하고 건축(공)학 교육의 뚜렷한 방향설정이 결여되고 교과내용의 개혁없이 각대학별로 획일적인 교과과정이 편성운영되고 있는 실정이다. 본고에서는 국내외 대학원교육의 현황과 그 문제점을 개관하고 바람직한 대한원교육의 방향설정에 필요한 몇가지 제언을 하고자 한다.
이경회 대한건축학회 1987 建築 Vol.31 No.1
본고에서는 인간.환경.건축의 상호관련성을 중심으로 건축환경계획의 내용과 그 영역설정문제를 고찰하여 보고자 한다.
鄭丙宰,李璟會 社團法人 韓國火災學會 1990 한국화재소방학회논문지 Vol.4 No.2
ABSTRACTFire Protection System is facilities that Control the fire by mechanic means. Buildings Over a Certain Scale is required this system. As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment the kinds are various. With the development of architecture technique while modem higer bui- ldings are increased. As fire is a first product that human make, it performed many profits and services for our mankind.Sometimes as it is profitable fire or harmful fire, it takes charge of human's life culture. Therefore fire protection system is facilities that control the latter fire by mechanic means Building over a certain scale is required this system.As the small from the fire extinguisher as the large to the sprinkler system of automatic fire extinguishing equipment, the kinds are various.With the development of architecture technique while modern higher buildings are increased high level and fire prevent facilities aren't reached to that level. The object of this study is present the problem which appear from the analysis of place standard for fire protection facility. This study described as a following order. First, We are going to look history of the fire protection system and change course of that with the year and facility Second, We say the frame system and special nature of the foreign fire prevent Act. Third, We understand the control reality of fire protection system. Fourth, We took out the merit of foreign fire prevent law and the problem of our current domestic system The placing standard of proper fire protection facilities that be presented from this study are followed next 1) We have to reinforce sprinkler system placing standard for the fire extinguishing and check the spread of fire. 2) We must to be ruled the standard for keeping fire prevention system that are received reality and people's idea. 3) We should prepare lawful basis which can be place fire prevention center. 4f We have to correct the standard of use count about complex building without mainuse and we take increase the real effectiveness of this. 5) We ought to match the use of current fire prevention act and the use of architecture law.