무효전력 민감도와 부하지속곡선을 활용한 적정 부하역률의 효과적인 산정 기법에 관한 연구
이병하(Byung Ha Lee),황승호(Sung-Ho Hwang) 대한전기학회 2012 전기학회논문지 Vol.61 No.12
In this paper, a methodology to use load duration curve and the reactive power factor sensitivity of generation cost is proposed for analyzing the effects of load power factor effectively. A great deal of cases of power systems are classified into several patterns according to the characteristics using load duration curve, and the overall effects of load power factor are assessed by integrating the analysis results of load power factor in all the patterns. The reactive power sensitivity of generation cost and the integrated costs such as generation cost, investment cost, voltage variation penalty cost and CO2 emission cost are used for determining an appropriate load power factor. A systematic procedure for effective analysis of load power factor is presented. It is shown through the application to the practical power system of KEPCO(Korea Electric Power Corporation)that the effects of load power factor can be analyzed effectively using load duration curve and reactive power factor sensitivity.
선로유효전력 Tracing과 민감도를 활용한 선로 과부하 해소 스위칭 및 모선분리 알고리즘에 관한 연구
이병하(Byung Ha Lee),황승호(Sung-Ho Hwang) 대한전기학회 2011 전기학회논문지 Vol.60 No.11
In this paper, a new algorithm for alleviating overloads in power networks by the use of line power tracing and sensitivity is proposed to perform line switching and bus separation effectively. Also, a new bus separation index based on line power tracing is presented to find the bus to be separated for relieving overloads effectively. By applying the sensitivity of the line flow with respect to the change of the line impedance, both switching-on and switching-off of the lines for alleviating overloads in power networks are performed systematically at once. The number of the considered cases for line switching and bus separation can be greatly reduced and the best combination of line switching and bus separation can be acquired efficiently by the use of the sensitivity and the bus separation index. In order to show the effects of this algorithm, it is applied to a small scale power system of IEEE 39-bus system and practical power systems of KEPCO.
모듈온도에 따른 전압-전류 특성 (pp.2150-2151)
정유라(Yoo-Ra Jung),박상준(Sang-Jun Park),황승호(Seung-Ho Hwang),최용성(Yong-Sung Choi),이경섭(Kyung-Sup Lee) 대한전기학회 2009 대한전기학회 학술대회 논문집 Vol.2009 No.7
Solar, as an ideal renewable energy, has inexhaustible, clean and safe characteristics. However, solar energy is an extreme intermittent and inconstant energy source. In order to improve the photovoltaic system efficiency and utilize the solar energy more fully, and the DC current vary with module temperature, it is necessary to study the characteristics of photovoltaic I-V according to the external factors. This paper presents the analysis of characteristics of photovoltaic I-V according to the module temperature. The results show that it seems that when the module temperature increases, the DC current increases. But actually, because when the irradiation increases, the DC current increases, the result of the relationship between DC current and the module temperature of solar cell will be effects by the increasing irradiation.