http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
차량용 가변사판식 압축기의 흡입체크밸브 최적화에 관한 연구
이봉섭(Bongsub Lee),이용주(Yongju Lee),이태진(Taejin Lee),한준석(Junseok Han),배인표(Inpyo Bae),이건호(Geonho Lee) 대한설비공학회 2016 대한설비공학회 학술발표대회논문집 Vol.2016 No.6
Development of a compressor for vehicle air conditioning system has been focused on high performance and noise reduction. Suction check valve is used to prevent the noise that is caused by the suction pulsation when a clutch-less compressor is operating in an OFF state. However, the suction pressure drop due to the increased flow resistance reduces the cooling capacity of a compressor. The aim at this study is to predict the cooling capacity drop rate and improving the performance with optimized suction check valve shapes. It proposed the theoretical cooling capacity drop rate, and the experimental studies were carried out in order to verify this. But those were not matched each other so that CFD analysis program was used to look for the cause. Results show that the pressure distribution of a valve surfaces affects the suction pressure drop. The cooling capacity was improved by the suction check valve that is modified to increase average pressure on a valve surface.