조장세,나성준,김민숙,이영학,김희철,Cho, Jang-Se,La, Sung-Jun,Kim, Min-Sook,Lee, Young-Hak,Kim, Hee-Cheul 한국전산구조공학회 2011 한국전산구조공학회논문집 Vol.24 No.1
For reinforced concrete members, the bond strength is one of the important factors between two materials: concrete and reinforcing element. This study concerns the bond strength of deformed bars in artificial lightweight aggregate concrete by pull-out test. 144 cubic specimens were manufactured for the test. concrete compressive strength, size of deformed bar and embedment lengths were considered as variables in this study. Normal concrete with W/C ratio 50% specimens were tested for the comparison. Test results included the bond stress-slip responses and modes of failure. Bond strength increased with an increase of compressive strength of concrete according to W/C ratio. The equation of bond stress of polymer-modified lightweight aggregate concrete were proposed by regression analysis based on the result. 철근 콘크리트 부재에서 부착강도는 콘크리트와 보강근 사이에 중요한 요소 중 하나이다. 본 실험에서는 인공경량골재를 사용한 경량콘크리트와 이형철근의 부착강도의 특성을 확인하기 위하여 인발실험을 수행하였다. 콘크리트의 압축강도, 이형철근의 직경과 묻힘길이를 변수로 하는 144개의 인발실험 시험체가 사용되었다. 보통콘크리트와의 비교를 위하여 물/시멘트 비 50%의 보통콘크리트의 인발실험을 수행하였으며, 실험을 통해서 부착응력-미끌림 관계와 파괴형상을 평가하였다. 물/시멘트 비에 따른 콘크리트의 압축강도가 증가할수록 부착강도는 증가하였다. 또한 인발실험을 토대로 회귀분석을 실시하여 경량 콘크리트의 부착응력에 대한 산정식을 제안하였다.
FRP Bar로 보강된 콘크리트 깊은보의 전단강도에 관한 실험적 연구
조장세,김민숙,이영학,김희철,Cho, Jang-Se,Kim, Min-Sook,Lee, Young-Hak,Kim, Hee-Cheul 한국전산구조공학회 2011 한국전산구조공학회논문집 Vol.24 No.1
본 연구는 섬유 보강 폴리머(Fiber Reinforced Polymers, 이하 FRP) bar로 보강된 콘크리트 깊은보의 전단강도을 평가하기 위하여 전단경간비, 보강비, 유효깊이, 주근의 종류를 변수로 총 15개의 시험체에 대한 전단 실험을 수행하였다. 전단 실험을 토대로 FRP bar로 보강된 콘크리트 깊은보의 균열 및 처짐에 대한 거동 조사를 수행하였으며, ACI 318-08의 스트럿-타이 모델(이하 STM)을 이용한 전단강도와 아치작용을 고려한 기존 제안식에 의한 전단강도를 비교 평가하였다. 그 결과 FRP bar로 보강한 경우가 Steel bar로 보강한 경우보다 전단강도가 증가하는 것으로 나타났으며, 전단강도 산정에 있어 ACI 318-08 STM을 이용한 방법이 경험식에 의한 방법보다 상대적으로 정확했다. This study carried out shear experiment for concrete deep beam reinforced FRP(Fiber Reinforced Polymers) bar to investigate shear strength of deep beam. The test conducted for 15 specimens, and the variables were shear span-to-depth ratio, reinforcement ratio, effective depth, reinforcement components of shear strength. crack, deflection are investigated based on shear experimental. We compared shear strength using ACI 318-08 STM with proposed equations that considered arching action according to shear span-to-depth ratio. Consequently shear strength of deep beam reinforced FRP bar presented higher shear strength than steel bar. ACI STM's predictions are better accurate than other predicting equations.
AFRP rebar로 보강된 콘크리트 깊은보의 전단강도
이영학,김민숙,조장세,김희철 한국지진공학회 2009 한국지진공학회논문집 Vol.13 No.6
본 연구는 아라미드 섬유 보강 폴리머(Aramid Fiber Reinforced Polymers, 이하 AFRP)rebar로 보강된 콘크리트 깊은보의 전단강도를 평가하기 위하여 전단경간비, 보강비, 유효깊이, 주근을 변수로 총 8본의 시험체에 대한 전단 실험을 수행하였다. ACI 318-08의 스트럿-타이 모델(이하 STM)을 이용한 전단강도와 아치작용을 고려한 제안식에 의한 전단강도를 비교-평가하였으며, 그 결과 AFRP rebar로 보강한 경우, Steel rebar로 보강한 경우보다 전단강도가 증가하는 것으로 나타났다. 전단강도 산정에 있어 ACI 318-08 STM을 이용한 해석이 상대적으로 정확했으며, 실험결과를 토대로 스트럿의 크기효과를 고려한 유효압축강도 산정 모델을 제안하였다. 이를 본 실험에 적용시킨 결과 기존 기준 및 제안식을 이용한 전단강도 산정방법보다 합리적인 결과를 얻을 수 있었다. This study carried out a shear experiment on concrete deep beam reinforced AFRP to investigate the shear strength of deep beam. The test was conducted on 8 specimens, and the variables were shear span ratio, reinforcement ratio, effective depth, and rebar type. We compared shear strength using ACI 318-08 STM with proposed equations that considered arching action according to shear span ratio. As a result, it was found that shear strength of deep beam reinforced AFRP rebar presented higher shear strength than steel rebar. ACI STM's predictions are more accurate than other predicting equations, and thus this research proposed model versus effective compressive strength of the concrete strut that considered strut size effect based on test results. The predictions obtained using the proposed model are in better agreement than previous equations and codes.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.
H형강 프레임으로 보강한 철근 콘크리트 구조물의 내진보강 사례
황대성 ( Hwang Dae-sung ),조장세 ( Cho Jang-se ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 학술발표대회 논문집 Vol.25 No.1
내진성능이 확보되지 않은 기존 구조물의 성능을 향상시킬 수 있는 공법인 H형강 창호프레임 공법은 중·약 지진 발생되는 국내에 적합한 공법이다. 구조물의 보강 조건에 따라 기존 구조체 면내에 끼우는 형태와 외부에 부착하는 입체형태가 있으며, 각 형태는 2층 실물실험을 통하여 내진성능 검증하였다. 본 연구에서는 H형강 창호프레임을 적용하여 내진성능을 확보한 부산시민회관의 보강설계 시 주요사항, 보강효과을 소개한다.