http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Jung-hoon Kim(김정훈),Yong-In Cho(조용인) 한국방사선학회 2018 한국방사선학회 논문지 Vol.12 No.2
In the field of angiography and interventional radiology, it is said that the risk of radiation exposure to the eyes is high due to the characteristics of work, but currently divided dose assessment and management are not carried out in reality. Therefore, in this study, in order to evaluate the dose of the operator in the surgical environment and to analyze the shields, firstly, we selected the point where the operator is mainly located, evaluated the exposure dose of the eye after attaching the pocket dosimeter to the lateral angle point of the head and neck phantom, and evaluate shielding effect when wearing lead glasses that is currently commercialized. Secondly, we evaluated the tendency of the exposure dose of the eye and the shielding effect through simulation in the same geometric structure as the actual measurement. As a result, in the case of measurement using a dosimeter, the cumulative dose increased with the increase of the fluoroscopic time, and the tendency was different according to the position of the operator. Simulation results show that the dose distribution of the eye lens in the mathematical phantom is about 1.1 ~ 1.3 times higher than that of the cornea. Also, The protective effect of the lead glasses showed a shielding effect of at least 3.7 ~ 21.4% in each eye. 혈관조영 및 중재적 방사선학 분야의 경우, 업무 특성상 눈의 방사선 피폭에 대한 위험성이 높다고 알려져 있으나, 현재 구분된 선량평가 및 관리가 이루어지지 않는 실정이다. 이에 본 연구에서는 시술 환경 내 종사자의 눈에 대한 선량평가 및 차폐분석을 위해 첫 번째로, 시술자가 주로 위치하는 지점을 선정하고, 두경부 팬텀 눈의 외안각 지점에 포켓선량계를 부착한 뒤 눈에 대한 피폭선량을 평가하였고, 현재 상용화된 납 안경 착용 시 차폐효과를 산정하였다. 두 번째로, 실측과 동일한 기하학적 구조 내 모의실험을 통해 눈의 피폭선량에 대한 경향성 평가와 차폐효과에 대해 분석하였다. 그 결과, 선량계를 이용한 측정의 경우, 방사선 투시촬영 시간이 증가함에 따라 누적선량이 증가하였고, 또한 시술자의 위치에 따라 각기 다른 양상을 보였다. 모의실험의 경우, 수학적 팬텀 내 눈의 수정체의 경우 각막보다 약 1.1~1.3배 높은 선량분포를 나타내는 것을 확인하였고, 납 안경의 방호효과는 눈의 각 기관별로 최소 3.7 ~최대 21.4% 차폐효과를 보였다.
PET/CT 업무 환경에서 선원 취급 시 Apron의 실효성 평가
조용인(Yong-In Cho),예수영(Soo-Young Ye),김정훈(Jung-Hoon Kim) 대한방사선과학회(구 대한방사선기술학회) 2015 방사선기술과학 Vol.38 No.3
핵의학 종사자는 PET/CT 업무 환경 중 방사성 의약품 취급 시 상당히 높은 피폭선량을 받는다고 알려져 있으며, 이를 최소화하기 위해 적절한 차폐기구의 사용이 요구된다. 이에 본 연구에서는 몬테카를로 기법을 기반으로 한 모의실험과 실측을 통해 18F-FDG 선원 취급 시 Apron 착용에 대한 차폐효과에 대해 분석하였다. 그 결과, 모의실험의 경우 선원의 취급 위치에 따라 인체 장기별 선량 분포가 각각 다른 양상을 나타냈고, Apron 납 두께별 선량 감소율은 선원과 장기와의 위치가 근접할수록, 선원과의 접촉 거리가 멀수록 낮은 경향을 나타냈다. 선량 측정 장비를 통한 실측의 경우, 측정 장비간 특성으로 인해 평균 공간 선량률 분포는 상이한 결과를 보였으나, 거리 별 납 당량의 증가에 따라 지수함수분포로 공간 선량률이 감소되었다. Health professionals in nuclear medicine were known that they get high radiation exposure. To reduce radiation exposure, using shielding materials is needed. In this study, we analyzed the shielding effect about apron during 18F-FDG treatment by using simulation based on Monte Carlo techniques and actual measurement. As a result, absorbed dose distribution of organ varies with handling position of the source. Dose re-duction ratio by lead thickness of apron tended to decease, when handling position of the source come close to organ and away from radiation source for simulation. In the case of actual measurement with the dosimetry device, It showed that mean spatial dose dis-tribution was different due to characteristics of dosimetry device. However, spatial dose rate was ex-ponentially reduced according to distance with increasing lead content.
골밀도검사에서 피검자의 장기선량 측정 및 차폐기구의 효용성 평가
조용인(Cho Yong-In),김정훈(Kim Jung-Hoon) 대한방사선과학회(구 대한방사선기술학회) 2020 방사선기술과학 Vol.43 No.3
Bone mineral density is a examination to measure the amount of bone in patients with metabolic bone disease. It is a low dose, but may cause unnecessary exposure to the gonads and other organs located in the periphery when examining the lumbar and proximal femurs. Therefore, the purpose of this study was to evaluated the exposure dose for each organ exposed during the bone mineral density through simulation, and analyzed the applicability of the subject to radiation shielding devices using 3D printing materials. As a result, the highest dose was shown at 11.47 uSv in the breast during lumbar examination and 8.98 uSv in the testis during proximal femur examination. Also, the farther away from the examination site, the lower the effect of the scattering-ray. The shielding effect of using 3D printing shielding device showed high results in proportion to the effective atomic number and specific gravity of the printing material. Among t he p rinting materials, A BS + W showed an e ffect o f at l east 78.72 to 9 6.3 9% c ompared to t he e xisting lead material.
CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가
조용인(Yong In Cho),김정훈(Jung Hoon Kim) 한국방사선학회 2020 한국방사선학회 논문지 Vol.14 No.2
The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender. 국민의 의료수준 향상으로 CT 검사건수는 매년 증가되고 있는 추세이며, 이에 따라 연간 의료 방사선에 의한 피폭선량 또한 증가되고 있다. 이에 본 연구에서는 CT 부위별 검사 시 노출되는 인체의 유효선량을 평가하고, 이로 인한 생애 암 귀속 위험도를 추정하고자 한다. 첫 번째로, CT 진단참고수준 가이드라인에서 제시하는 부위 중 5가지를 선정하였으며, CT 장치를 통해 각 검사 부위별로 노출되는 인체의 유효선량을 평가하였다. 두 번째로, 동일한 조건 내 ALARA-CT 프로그램을 이용하여 인체 장기 및 유효선량을 산정하였으며, 국내 DRL 수준과 비교하여 검사 프로토콜에 대한 적정성을 평가하였다. 세 번째로, CT 검사 시 노출되는 유효선량에 의한 생애 암 귀속 위험도(LAR)을 추정하였다. 그 결과, 검사 중 복부 다중시기 검사 시 21.18 mSv로 가장 높은 유효선량을 나타내었으며, 복부검사를 제외한 나머지 검사에서는 DRL 이하의 선량수준을 나타내었다. 동일한 조건 내 선량계산 프로그램을 이용한 유효선량 평가 결과, 각 검사별로 약 1.1~1.9배 이상 높은 결과를 나타내었으며, 장기선량의 경우 검사 부위에 근접한 장기일수록 산란선에 의해 높은 영향을 나타내었다. CT 검사 시 성인의 생애 암 귀속 위험도의 경우, 연령이 증가함에 따라 점차적으로 감소되는 양상을 보였으며, 성별에 따라 다소 상이한 결과를 나타내었다.