RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        치과용 비귀금속합금의 식각표면에 대한 주사전자현미경적 연구

        정헌영,이선형,Chung, Hun-Young,Lee, Sun-Hyung 대한치과보철학회 1985 대한치과보철학회지 Vol.23 No.1

        The purpose of this study was to evaluate microstructures on the etched surface of 11 base metal alloys for dental restorations and to observe the relationship between the etching pattern and beryllium. For this purpose, the following experiments were done; 11 base metal alloys were etched in (1) 10% $H_2SO_4$, (2) 10% $H_2SO_4$, 9 parts+methanol 1 part (3) Conc. $HNO_3$ 25%+glacial acetic acid 25%+$H_2O$ 50% (4) Conc. $HNO_3$ 5% (5) 2% glacial acetic acid added to Conc. $HNO_3$ 1% solution, with their etching conditions varied. Etched surface of alloys were examined under the scanning electron microscope. Results were as follows; 1. Almost all of Ni-Cr-Be alloys showed gooed etchd surface in $H_2SO_4$, solution, while some of those alloys which contains no beryllium showed good etched surface in $HNO_3$ solution. 2. Main components of etching solution can vary etching pattern of alloys. 3. Gamma prime phase relief, which can be found in all Ni-Cr-Be alloys, can't be found in any alloy that contains no beryllium.

      • 금관 가공의치에서의 대구치 지대치에 관한 형태학적 연구

        정헌영,Chung, Hun-Young 대한심미치과학회 1995 Journal of the Korean Academy of Esthetic Dentistr Vol.3 No.1

        Abutment dies which resemble the actual size and shape of crown abutment is essential in most of the research area of fixed prosthodontics like marginal accuracy, crown seating, behavior of luting agent and so on. Seeing the large portion of research is done with round shaped dies in different size and cone angles, the necessity of research on the crown abutment is self-evident. 500 molar abutments were collected randomly through the commercial dental laboratoy, regrdless of their position in the dental arch, sex, and age. The measurements of 22 points of a die were done, and the results were as fogbows : 1. The height of the molar dies was $3.9{\pm}1.2mm$ 2. The bucco-lingual width was $8.9{\pm}1.2mm$ at the base, and $7.4{\pm}1.2mm$ at the occlusal. 3. The desio-sistal width was $8.2{\pm}1.2mm$ at the base, and $7.0{\pm}1.3mm$ at the occlusal.

      • KCI등재
      • KCI등재

        글레이징처리한 도재와 연마한 도재의 표면조도에 관한 연구

        최미라,정헌영,이선형,양재호,Choi, Mee-Ra,Chung, Hun-Young,Lee, Sun-Hyeong,Yang, Jae-Ho 대한치과보철학회 1998 대한치과보철학회지 Vol.36 No.4

        Porcelain is considered to be one of the materials of choice for restoration where esthetics is of concern. But porcelain surface without final glazing treatment may induce undesirable results such as inflammatory response on adjacent soft tissues due to plaque accumulation and increased wear of opposing teeth. Therefore, rough porcelain surface must be smoothened by final glazing treatment or chairside polishing procedure. The purpose of this study was to compare the surface roughness among self-glazed, overglazed and polished porcelain with various polishing kit, and to detect which phase of polishing is optimal in clinic. Specimens were fabricated with Vita VMK porcelain. The surface treatment of each group was performed as follows. Group 1 : overglazing treatment Group 2 : self-glazing treatment Group 3 : polishing with the Truluster Polishing System for Porcelain(Brasseler, U.S.A.) Group 4 : polishing with the Exa Cerapol Adjustment kit (Edenta dental products, Switzerland) followed by finishing with diamond-filled polishing paste Group 5 : polishing with the Shofu Porcelain Adjustment kit (Shofu inc., Japan) followed by finishing with diamond-filled polishing paste. At each polishing steps, the measurement of Ra and Rq values were performed, and the surface was examined by scanning electron microscope. The results were as follows : 1. Overglazing treatment brought smoother surface than self-glazing treatment. 2. Polishing systems without porcelain polishing paste did not make better result than self-glazing treatment. 3. Polishing system with porcelain polishing paste made similar result to overglazing treatment. 4. Applying diamond-filled polishing paste after using polishing system which has no porcelain polishing paste produced surface as smooth as overglazing treatment does.

      • KCI등재

        도재전장금관을 위한 코핑의 변형에 관한 연구

        이기홍,정헌영,이선형,양재호,Lee, Ki-Hong,Chung, Hun-Young,Lee, Sun-Hyung,Yang, Jae-Ho 대한치과보철학회 1997 대한치과보철학회지 Vol.35 No.4

        Ceramometal crowns are common restorations in fixed prosthodontics because of their casting accuracy, the high strength properties of the metal, and the cosmetic appearance of porcelain. However, deterioration of the initial fit of the metal coping has been observed after the porcelain firing cycle. The distortion due to repeated firing makes it difficult to fit crown margin and elicits microleakage. The major causes of distortion are the residual stress that accumulate during wax-up, casting, cold work and the induced stress caused by the mismatch of porcelain-metal thermal contraction. This study examined the marginal fit changes of metal copings in relation to repeated firing and the effects of heat treatment that reduce the distortion resulted from residual stress. The marginal changes of the copings that were treated with conventional method and those treated with heat before repeated firing, were evaluated. The metal die which represented preparations of a maxillary central incisor was fabricated, and 45 wax patterns were cast with nonprecious metal alloys. The heat treatment of each group was performed as follows. Group 1(control) : Casting - Devesting - Cold work - Firing Group 2 : Casting - Heat treatment - Devesting - Cold work - Firing Group 3 : Casting - Devesting - Cold work - Reinvesting - Heat treatment - Devesting - Firing The copings were fired 3 times. After each firing, the marginal fit changes were measured with inverted metallurgical microscope at the 4 reference points located at labial, lingual, and both proximal surface. Measurements were compared, and statistically analyzed. The results were as follows ; 1. In all groups, the highest value of marginal fit changes of the copings studied were found after the first firing cycle. 2. When the distortion of each experimental group at the first firing cycle were compared, group 1 exhibited the greatest changes($20-27{\mu}m$), followed by group 2($9-13{\mu}m$), and group 3($8-10{\mu}m$). 3. The copings treated with heat before devesting(group 2) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 4. The copings treated with heat after reinvesting(group 3) revealed significantly smaller marginal fit changes than the copings treated with conventional method(group 1). (p<0.01) 5. No siginificant differences in marginal fit changes were found between the copings treated with heat before devesting(group 2) and the copings treated with heat after reinvesting(group 3). (p>0.01)

      • KCI등재

        고정성 치아보철에 관한 연구

        이선형,정헌영,최수영,Lee Sun-Hyung,Chung Hun-Young,Choi Soo-Young 대한치과보철학회 1994 대한치과보철학회지 Vol.32 No.3

        The number and the distribution of fixed restorations including crowns, fixed bridges, Maryland bridges, periodontal splints and cast cores were statistically investigated with two thousand seven hundred and thirty cases of crowns and bridges placed at the Department of Prosthodontics of Seoul National University Hospital, from January 4th to December 31st, 1988. The results were as follow : 1. Among the fixed restorarions, single crowns were 46.9% , fixed bridges were 41.9%, Maryland bridges were 5.0%, periodontal splints were 0.6% and cast cores were 5.6%. 2. Three thousand nine hundred and ninty two teeth were restored with the fixed restorations, among them cast gold restorations were 47.2% and metal-ceramic restorations were 52.8%. 3. Cast gold restorations of the maxillary posteriors occupied 98.5% of the maxillary cast gold restorations, and 99.7% of the mandibular cast gold restorations and metal-ceramic restoration of maxillary anteriors occupied 68.4% of the maxillary metal-ceramic restorations, and 38.7% of the mandibular metal- ceramic restorations. 4. It is recommended that the curriculum of the dental school for undergraduated students and graduated students should be changed to accomodate the relative importance of the restorations.

      • KCI등재

        반복 하중이 Full veneer crown의 유지력에 미치는 영향에 관한 연구

        김기연,이선형,정헌영,양재호,허성주,Kim, Ki-Youn,Lee, Sun-Hyung,Chung, Hun-Young,Yang, Jae-Ho,Heo, Seong-Joo 대한치과보철학회 2000 대한치과보철학회지 Vol.38 No.5

        Dislodgement of a crown or extension bridge and the loosening of a retainer of a bridge is a serious clinical problem in fixed restoration. Generally these problems are considered to be associated with deformation of the restoration. During biting, the restoration is subjected to complex forces and deforms considerably within the limit of its elasticity. Deformation of the restoration under the occlusal force induces excessive stress in the cement film, which then leads to the cement fracture. Such a fracture may eventually cause loss of the restoration. Because most of the past retention tests for full veneer crown were done without fatigue loading, they were not exactly simulating intraoral environment. And the purpose of this study was to evaluate the effect of cyclic cantilever loading on the retentive strength of full veneer crowns depending on different type of cements and taper of prepared abutment. Steel dies with $8^{\circ}\;or\;16^{\circ}$ convergence angle were fabricated through milling and crowns with the same method. These dies and crowns were divided into 8 groups. Group 1 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 2 : $16^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 3 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, without loading Group 4 : $8^{\circ}$ taper die, cementation with zinc phosphate cement, with loading Group 5 : $16^{\circ}$ taper die, cementation with Panavia 21, without loading Group 6 : $16^{\circ}$ taper die, cementation with Panavia 21, with loading Group 7 : $8^{\circ}$ taper die, cementation with Panavia 21 without loading Group 8 : $8^{\circ}$ taper die, cementation with Panavia 21, with loading After checking the fit of die and crown, the luting surface of dies and inner surface of crowns were air-abraded for 10 seconds. The crowns were cemented to the dies, with cements mixed according to the manufacturer's recommendations. A static load of 5kg was then applied for 10 minutes with static loading device. Twenty-four hours later, group 1, 3, 5, 7 were only thermocycled, group 2, 4, 6, 8 were subjected to cyclic loading after thermocycling. Retentive tests were performed on the Instron machine. From the finding of this study, the following conclusions were obtained 1. Panavia 21 showed significantly higher retentive strength than zinc phosphate cement for all groups (p<0.05). 2. There was a significant difference in the retentive strength between $8^{\circ}\;and\;16^{\circ}$ taper for zinc phosphate cement(p<0.05), but no significant difference for Panavia 21 (p>0.05). 3. Cyclic loading significantly decreased the retentive strength for all groups(p<0.05). 4. For zinc phosphate cement, there was 35% reduction of the retentive strength after loading in the $16^{\circ}$ taper die, 25% in the $8^{\circ}$ taper die, and for Panavia 21, 21% in the $16^{\circ}$ taper die, 18% in the $8^{\circ}$ taper die.

      • KCI등재

        접착성 레진 시멘트 와 법랑질 및 닉켈-크롬 합금 간의 전단결합강도

        이선형,양재호,정헌영,장일성,Lee, Sun-Hyung,Yang, Jae-Ho,Chung, Hun-Young,Jang, Il-Seong 대한치과보철학회 1997 대한치과보철학회지 Vol.35 No.2

        This study was executed to measure the shear bond strength of Panavia EX and Panavia 21 when the Ni-Cr-Be alloy castings were cemented to the enamel surfaces with these cements. The cast metal plates of Ni-Cr-Be alloy were sandblasted and cemented to acid etched enamel surface with Panavia EX or Panavia 21. Their shear bond strength were measured with Instron Universal Testing machine. Within the limits of this study, following conclusions were withdrawn. 1. The mean shear bond strength were 26.85.7MPa, in Panavia EX and 28.35.2MPa, in Panavia 21. 2. t-Test revealed no statistical significance between two groups(.05 level) 3. Macroscopically, bond failures were revealed compound fracture at metal and enamel interfaces, in cases of both cements, as the cement attached partly on both metal and enamel surface.

      • KCI등재
      • KCI등재

        최대교합 및 기능교합시 하악구치부 연장가공의치에 발생하는 응력에 대한 삼차원 유한요소법적 연구

        박창근,이선형,정헌영,양재호,Park Chang-Keun,Lee Sun-Hyung,Chung Hun-Young,Yang Jae-Ho 대한치과보철학회 1994 대한치과보철학회지 Vol.32 No.4

        Cantilever bridge is widely used by mny clinicians, but its worst mechanical character, so called Class I lever system, makes dentists hesitate to restore the missing tooth with it. Therefore it is important to study stress of the cantilever bridge. In this study, two models of cantilever bridges that restores the missing mandibular second molar with two abutment teeth were constructed. One model was a type of cantilever bridge supported by a normal alveolar bone, the other one was supported by an alveolar bone resorbed to its 1/3 of root length. Maximum bite force(550N) and funtional maximum bite force(300N) were vertically applied to the distal end of the pontic, distal 1/3, and distal half of the pontic. And each force was also applied to centric occlusal contacts as a distributed force. Total 16 loading cases were compared and analyzed with 3-dimensional finite element method. The results were as follows: 1. The stress was concentrated on the joint of the pontic and the retainer, grooves, and distal cervical margin of the posterior retainer. 2. In case of maximum bite force(550N) at the end of the pontic, the risk of fracture at the joint of the pontic and the retainer was high. 3. In case of distributed force in centric occlusion and functional maximum bite force(300N), the stresses were less than the yield strength of the type VI gold for any loading cases. 4. In case of alveolar bone resorption, the occlusal force to the cantilever pontic caused more stress on the root apex and less stress on the alveolar crest region of the distal surface of the posterior abutment. 5. In case of alveolar bone resorption, the displacement was larger than that of normal alveolar bone in all loading cases.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼