정기범(Jeong Kybum),최상곤(Choi Sang-Gon) 한국태양에너지학회 2010 한국태양에너지학회 논문집 Vol.30 No.3
Global warming and heat island make the outdoor air temperature ascend. Tall office buildings are covered with glass window facades as a design aspect and the portion of window area to facade area is increasing. Hence, cooling load for solar radiation passing through glass window is rising. Cooling air to a certain room is supplied equally despite the face of the room in most office buildings. Especially, the west part of the office cannot maintain the required temperature that occupant needs because of the solar heat coming through windows. In this study, we projected the water spray system to reduce the solar heat transfer and to reflect the solar ray through windows. We perform the experiments to evaluate the performance of the solar heat protection devices. We measured the room temperature of two separated office rooms for solar heat control devices. The investigation's results show that the water spray system is sufficient to the coated glass and the venetian blinds for the decrease of the solar heat inflow.
정기범(Kybum Jeong),최상곤(Sang Gon Choi) 대한설비공학회 2009 설비공학 논문집 Vol.21 No.1
The air sterilization systems are investigated experimentally in this paper. The goal is to reduce bacteria. mold and viruses in office air by using a UV sterilizer installed inside a partition panel and wall-mounted unit. These systems allow occupants to turn the system on/off and to control the incoming air speed and direction. The partition air sterilization system conditions and sterilizes the air, and then delivers the clean air into the personal task area through the partition panels, which are connected to the pressurized under-floor plenum. Room air exits through the return grills mounted on the ceiling. The wall-mounted air sterilization system sterilizes the air, and then delivers the clean air to the personal task area from the wall. In this study a full-size experimental environment is established to investigate the immunization performance of these air sterilization systems. A typical office space scale is used in this study in order to find an optimal system to achieve a sterilized healthy micro-environment. Multiple system parameters, including volume flow rate and velocity of supplied air, were regulated during the experiments. The more air contact these air sterilization systems had, the better disinfection performance. Over 90% of eradication ratios were obtained by these two air sterilization systems. The results indicate that these systems can efficiently disinfect office air contamination.