전기장이 인가된 상태에서 폴리에틸렌으로 피복된 기울어진 전선을 통해 전파하는 화염에 대한 실험적 연구
임승재(Seungjae Lim),김민국(Minkuk Kim),박정(Jeong Park),정석호(Sukho Chung),Osamu Fujita 한국연소학회 2014 KOSCOSYMPOSIUM논문집 Vol.2014 No.11
An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.
폴리에틸렌으로 피복된 기울어진 전선을 통한 화염전파에 대한 실험적 연구
임승재(Seungjae Lim),박정(Jeong Park),김민국(Minkuk Kim),정석호(Sukho Chung),Fusita Osamu 한국연소학회 2013 KOSCOSYMPOSIUM논문집 Vol.2013 No.12
The Experimental study on flame spread over Polyethylene insulated slanted electrical wire was conducted with applied AC electric field. The results showed that flame slanted toward burnt side with AC electric field and slanted angle. The flame spread rate decreased with AC electric field, decreased initially with slanted angle and increased for high slanted angle. Flame extinction was characterized by applied voltage and frequency. Variation of spread rate could be explained by thermal balance mechanism.
교류 전기장이 인가된 폴리에틸렌으로 피복된 기울어진 상태의 전선을 통해 전파하는 화염에 대한 실험적 연구
임승재(Seungjae Lim),박정(Jeong Park),김민국(Minkuk Kim),정석호(Sukho Chung),Fujita Osamu 한국연소학회 2014 KOSCOSYMPOSIUM논문집 Vol.2014 No.5
A experimental study on spreading flame over slanted polyethylene insulated electrical wire with AC electric field was conducted. The results showed that flame leaned relatively toward burnt side and flame spread rate decreased with applied voltage and frequency. The flame spread rate could be characterized by logarithmically scaled frequency with applied voltage at each slanted angle. Without electric field, flame spread rate decreased up to 80˚, and then increased up to 90˚. Flame extinction voltage was characterized with logarithmically scaled frequency.
교류전기장이 인가된 전선을 통해 전파하는 화염에 있어서 기울어진 각도가 미치는 영향에 대한 실험적 연구
임승재(Seungjae Lim),김민국(Minkuk Kim),박정(Jeong Park),권오붕(OhBoong Kwon),정석호(Sukho Chung),Osamu Fujita 한국연소학회 2015 KOSCOSYMPOSIUM논문집 Vol.2015 No.12
An experimental study on downwardly and upwardly spreading flames over slanted electrical wire, which is insulated by Polyethylene(PE), was conducted with applied AC electric field. The result showed that downwardly and upwardly spreading flames with angle of inclination leaned toward burnt side and unburned side, respectively. With applied AC electric fields, size of downwardly spreading flame decreased slightly and that of upwardly spreading flame increased significantly. Flame spread rate showed various trends in terms of inclination, applied voltage and frequency.