이현두(H. D. Lee),박영호(Y. H Park),전세봉(S. B. Jeon),김종규(J. G. Kim),류승표(S. P. Ryu),이세현(S. H. Lee) 전력전자학회 2010 전력전자학술대회 논문집 Vol.2010 No.7
The main purpose of this study is to design and develop the grid connected 4㎾ photovoltatic PCS(Power Conditioning System) targeting for Japanese market. To make this task, the development of DC to DC converter, one phase inverter and EMI filters, and the research on connection between inverter and utility line are made. The developed 4㎾ PCS has fully carried out performance verifications and evaluation works and acquired the JET(Japan Electrical Safety & Environment Technology Laboratories) certification for safety and performace.
이현두(H.D. Lee),정만규(M.K. Jeong),고영철(Y.C. Ko),방이석(L.S. Bang) 전력전자학회 1999 전력전자학술대회 논문집 Vol.1999 No.7
This paper describes the characteristics of two methods about providing information needed for propulsion device control In train The one is to use new way using the communication network for transmission of control Information, the other is traditional way using hardwire connectin. And this paper descnbes the communication interface technique between TCMS(Train Control and Monitoring System) and VVVF inverter system with Loriworks network adapted to SMG line 6 which has been developed With this technique, an inertia load test carried out for the traction control environment and it is expecting a field test at SMG line 6.
이현두(H.D. Lee),김수남(S.N. Kim),류승표(S.P. Ryu),이세현(S.H. Lee) 전력전자학회 2005 전력전자학술대회 논문집 Vol.- No.-
This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.
이현두(H. D. Lee),전세봉(S. B. Jeon),이수병(S. B. Lee),김종규(J. G. Kim),류승표(S. P. Ryu) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
This paper describes the information transmission method using communication networks between the devices in Photovoltaic Power System, and also represents the test result which carried out in the field. In this test, transmission signal waveform, polling time, response time and request/response frame were measured between the devices. The measured results show the excellent transmission characteristics.
태양광 어레이 부분 그늘짐 현상 해석을 통한 최대 출력점 스캔 알고리즘 개발
박영호(Y. H. Park),우명호(M. H. Woo),전세봉(S. B. Jeon),이현두(H. D. Lee),김종규(J. K. Kim),류승표(S. P. Ryu),이세현(S. H. Lee) 전력전자학회 2009 전력전자학술대회 논문집 Vol.2009 No.1
PV(Photovoltaic) 시스템에서 태양광 모듈의 전압-전류 특성은 일사량 및 온도에 따라 변하므로 태양광 모듈의 동작점이 최대 출력점에 있도록 제어하는 PCS(Power Conditioning System)의 MPPT(Maximum Power Point Tracking) 제어가 매우 중요하다. 대용량 PV 시스템에선 주변 환경조건에 따라 모듈에 부분 그늘짐 현상이 발생할 수 있으며, 기존 MPPT 알고리즘으로 최대 출력점 추종제어가 불가능할 수 있다. 본 논문에서는 태양광 모듈의 시뮬레이션 모델을 PSCAD/EMTDC 기반으로 개발하여 부분 그늘짐 현상을 모의 해석하고 이에 대한 최대 출력점 스캔 알고리즘을 제시하여 그 타당성을 시험으로 검증하였다.
박영호(Y. H. Park),전세봉(S. B. Jeon),김종규(J. K. Kim),이현두(H. D. Lee),우명호(M. H. Woo),류승표(S. P. Ryu) 전력전자학회 2011 전력전자학술대회 논문집 Vol.2011 No.7
The voltage fluctuation is one of grid instability problems caused by a high penetration level of decentralized generating units such as photovoltaic (PV) systems. The reverse load flow by PV systems may lead to a grid voltage fluctuation and increases a risk of overvoltage in times of high solar irradiation. The grid voltage regulation of a PV power conditioning system (PCS) using reactive power is presented in this paper. The influence of reactive power supply by the PV system on the grid voltage is explained and the regulation capability of PCS is discussed. The performance and feasibility of presented method is verified by both simulation and experimental results. The results show that the concept described in this paper can be utilized to keep the grid voltage in its nominal range.