http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이한주,양재영,이창하,김진웅 연세대학교 산업기술연구소 1995 논문집 Vol.27 No.1
Pure-component adsorption equilibrium of H₂S and SO₂on clinoptilolite, 4A, and 5A zeolite were measured by volumetric method at 273,298 and 323K and up to pressure of latm. The adsorption capacity of 5A zeolite for H₂S and SO₂was better than the others. The experimental date were analyzed by Langmuir, Langmuir-Freundlich, and Toth model using non-linear regression method. The date were fitted equally well with Langmuir-Freundlich model and Toth model within ARD 2%. Isotherm parameters determined in this work may be usefull in PSA separation systems.
H2/CO 혼합기체의 단일탑 PSA 분리공정에 관한 연구
한상섭,이한주,양재영,이창하 한국화학공학회 1996 Korean Chemical Engineering Research(HWAHAK KONGHA Vol.34 No.3
성형 zeolite 5A 흡착제를 이용하여 PSA 공정에 의한 H₂/CO 혼합기체의 분리현상 및 공정성능을 실험하였고, 공정모사를 통해 실험치와 공정성능을 예측하여 보았다. PSA 공정연구를 위하여 혼합기체의 흡착평형, 흡착속도 그리고 파과실험이 수행되었으며, 흡착평형은 LRC 모형에 의해, 또한 흡착속도항은 Glueckauf LDF 모형을 적용하였으며, 탑 내의 비등온성을 고려하기 위해 총괄전열계수개념을 적용하였다. 파과곡선실험에 의한 물질전달대(MTZ)의 이동은 비례양식형거동을 보였고, 벌크(bulk)분리의 새로운 주 물질전달대 개념에 의한 본 계의 MTZ 폭은 14.50-51.46 ㎝, 이동속도는 0.25-0.62 ㎝/s이었다. 4단계 PSA 공정에 의해 본 조작조건하에서 H₂ 기체는 94.37-99.79%. CO기체는 48.37-52.39%의 순도를 얻을 수 있었으며, 회수율은 각각 50.81-62.66%와 96.20-97.09%이었다. 또한 5단계 PSA 공정에 의해 분리 된 H₂ 및 CO 기체에 대한 순도는 각각 95.29-97.09%와 53.20-56.88%이었고, 회수율은 각각 65.35-74.72%, 그리고 83.19-94.08%의 결과를 얻을 수 있었다. PSA 공정 중 탑의 최 대온도변화(ΔT)는 7.5℃이었으며, 본 흡착탑 모형에 의한 온도 상승시간과 온도 plateau의 폭을 매우 잘 예측하였다. PSA 공정 중 정화단계에서는 CO 기체의 탈착이 아주 느리게 나타났으며, 주기공정의 탈착단계에 의한 세정도를 높이기 위해서는 충분한 정화기체의 양뿐만 아니라 일정시간 이상의 탈착이 요구되었다. 그리고 4단계와 5단계로 구성된 PSA 전공정의 모사에 의해 각 단계의 탑내 농도 및 유속분포 등의 동력학적 특성을 확인할 수 있으며, 공정성능에 관한 전반적인 경향을 예측할 수 있었다. The separation of H₂/CO mixture by pressure swing adsorption(PSA) process packed by 5A zeolite was studied experimentally and theoretically, and the both results were compared. To study the PSA process, adsorption equilibrium for the H₂/CO mixture, adsorption rates, and breakthrough curves were studied. Based on these results, the PSA process was analysed numerically by the model using the linear driving force(LDF) model and the overall heat transfer coefficient, and compared with experimental results. The breakthrough curves showed mostly to be almost symmetrical, and the movement of mass transfer zone(MTZ) was found to follow the proportionate pattern behavior. Lengths and rates of movement of MTZ calculated by new definition for bulk separation were 14.50-51.46 ㎝ and 0.25-0.62 ㎝/s, respectively. The results of a four-step PSA process consisting of pressurization, adsorption, countercurrent depressurization and purge, were compared with those of the five-step PSA process with additional cocurrent depressurization following adsorption. The five-step PSA process showed improvement in the purity and recovery of CO, while the recovery of H₂ was decreased. The maximum temperature variation(ΔT) in the adsorption column(inside diameter of 2.2 ㎝) was found to be about 7.5℃, and the theoretical results based on the overall heat transfer coefficient predicted the thermal behavior of the column quite well. Since the desorption of CO in the purge step was found to be rather slow, a plenty of purge gas and long purge time was needed to regenerate the column. Finally, it was found that the numerical model provides a reasonable prediction of adsorption /desorption dynamics of the column and PSA process performances.