http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
우승하(Seungha Woo),전남주(Namju Jeon),이형철(Hyeongcheol Lee) 한국자동차공학회 2013 한국자동차공학회 부문종합 학술대회 Vol.2013 No.5
This paper presents the fault detection and isolation algorithm for an in-wheel motor drive vehicle by using the model based application. Using decentralized and centralized method is to be determined to optimize trade-off relation between sensitivity and robustness. DFDD approach is suitable for an individual single processor such as each motor, inverter, acceleration/brake pedal and battery. On the other hand, CFDD approach is better for communication of multiple processors that detects and diagnosis faults. Before simulating the model, the fault models of pedal position sensors and the battery states are applied on the model and controller developed by Matlab/Simulink program. The proposed FDI algorithm is verified on the environment containing the system model.
AO 33-A3 유형의 대퇴골 원위부 골절에서 2.4 mm 수부 골접합용 금속판을 이용한 정복 및 내고정술의 용이성 - 수술 술기 -
이봉주 ( Bong-ju Lee ),윤자영 ( Ja-yeong Yoon ),우승하 ( Seungha Woo ) 대한골절학회 2023 대한골절학회지 Vol.36 No.1
AO 33-A3 유형의 대퇴골 원위부 횡형 및 분쇄 골절(metaphyseal transverse and comminuted fracture)은 골편 및 골절 부위 정복 후 유지가 힘들고 이에 반복되는 정복 소실에 따른 수술시간이 길어지고 출혈이 많이 발생할 수 있다. 본 저자들은 2.4 mm HPS의 offset grid plate (OsteoMed)를 이용하여 정복을 보다 쉽게 유지하고 견고한 내고정을 통해 골유합을 정상적으로 얻어낸 증례가 있어 보고하고자 한다. 정복후 유지를 위한 K-wire, 나사못 등을 시도하지 않아도 되며 대퇴골 외측부에 금속판 및 나사못 고정을 마칠 때까지 유지가 잘되어 비교적 쉽게 수술을 마칠 수 있었다. 수부 골접합용 금속판은 피질골의 만곡이나 형태와 잘 맞아서 별도 조작이 필요가 없으며 특정 형태의 대퇴골 원위부 골절에 있어서 정복 후 유지를 위한 목적으로 이용하기에 좋은 방법이라고 생각된다. Open reduction in an AO 33-A3 class distal femur transverse and comminuted fracture is often difficult due to frequent reduction loss during surgery, leading to longer operative time and increased blood loss intra-operation. In this study, the authors report a case in which the use of an offset grid plate (OsteoMed, USA) using 2.4 mm HPS (hand plating system) eased the process of fracture reduction and achieved a stable internal fixation, ultimately leading to successful osteosynthesis. The authors experienced no need for temporary fixation devices such as K-wires or screws, which are otherwise required to stabilize the reduction. The fracture reduction was stable throughout the primary fixation of the fracture using a locking plate and screws. The authors report that the advantage of the HPS plate is fitting into the cortical contour and providing stable maintenance of fracture reduction intra-operation, which would be beneficial in certain distal femoral fracture patterns.