http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
옥경재,이춘하 한국화재소방학회 2007 한국화재소방학회논문지 Vol.21 No.3
This experimental study showed the tracking characteristics of contaminated insulating materials. To analysis tracking characteristics, IEC 60112 was used. As the results of this study, the tracking characteristics of contaminated insulating materials showed as followings : (a) Comparative tracking index (CTI) of contaminated insulating material was lower than non-contaminated one. (b) First carbonized growth time and track growth time of contaminated insulating materials was faster than non-contaminated. 본 실험은 오염된 절연재료의 트래킹 특성을 연구하였다. 오염된 절연재료의 트래킹에 의한 절연파괴 특 성 분석은 IEC 60112를 통하여 수행하였다. 연구결과, 오염된 절연재료의 트래킹 특성은 다음과 같다. (a) 오염된 절연재료의 경우 정상시료 보다 비교트래킹지수(comparative tracking index, CTI)가 낮게 나 타났다. (b) 오염된 절연재료의 최초 탄화흔 발생시간 및 탄화도전로 형성 시간이 정상시료 보다 빠르게 나타났다.
옥경재(Ok, Kyung-Jea),차하나(Cha, Ha-Na),김시국(Kim, Shi-Kuk),이춘하(Lee, Chun-Ha) 한국화재소방학회 2008 한국화재소방학회 학술대회 논문집 Vol.2008 No.춘계
Fire prevention strategies should be aimed at the prevention of structured fire since average annual rates of structured fire have been increased due to economic growth resulted in increasing high rise buildings and multipurpose occupancies over the past ten years. Hence, this study mainly focused on the improve method and problems in the field test of fire detector in compliances with experimental consideration. And it leads us to the flowing conclusions : Firstly, it is necessary to formulate a safety standards on field test. Nowadays, the test enforced in many ways without formulated standard. Therefore it is necessary to be complete the arrangements standardized and how to do the test with formulated safety standards. Second, it is necessary to establish the regal guidance with regard to inspection equipment, ie density, component and temperature of test equipment should be considered. Also the equipment is need to be standardized and improved. Third, fire inspector's competency in their practice should be enhanced. The problems arising from the lack of knowledge and competence regarding inspection could be settled by providing professional education to ensure proficiency in their practice. Specialized training, as has been noted, should be offered in accordance with occupancy type, scale and fire protection system in the fire facilities.
이춘하,옥경재,김시국 한국화재소방학회 2008 한국화재소방학회논문지 Vol.22 No.1
This paper studied on the causal analysis of electrical fire by using fuse that it is used with safety device in electrical products. The experimental samples used are glass tube fuse (15 A, 5 × 20 mm) and temperature fuse (10 A, 72 oC). The experiment analyzed on the characteristics of damaged fuse by main causes (short circuit, overload, external flame) of electrical fire. The results showed, in case of glass tube fuse identified different characteristics in external form and element surface and element texture of damaged fuse by main causes of electrical fire. In case of temperature fuse identified different characteristics in external form and sliding contact surface and sliding contact texture of damaged fuse only by external flame. 본 논문은 전기제품 내에 안전장치로 사용되는 퓨즈를 이용한 전기화재의 원인분석에 관한 연구이다. 시 료는 유리관퓨즈(정격 15A, 5×20 mm)와 온도퓨즈(정격 10A, 72 oC)를 사용하였다. 전기화재의 주요원 인인 단락 및 과부하 그리고 외부화염을 인위적으로 가하여 소손된 퓨즈의 특성을 비교ㆍ분석하였다. 실 험결과 유리관퓨즈의 경우 소손된 퓨즈의 외형 및 표면 그리고 조직분석에서 서로 다른 특징들을 확인할 수 있었다. 온도퓨즈의 경우 외부화염실험의 경우에서만 소손된 퓨즈의 외형 및 가동접점의 표면 그리고 조직분석에서 뚜렷한 특징이 나타났다.
전압인가식 제전기의 방전에 의한 가연성가스의 폭발에 관한 연구
이춘하,옥경재,김점호,권병덕,차하나,윤계원 한국화재소방학회 2004 한국화재소방학회논문지 Vol.18 No.4
The static eliminator is used for prevention of disasters by static discharge, improvement of production efficiency, protection of a sensitive electronic element on the discharge of static, and it is handled for elimination of static in the painting plant, the film manufacturing plant, the producing semi-conductor factory. This study described on the explosion appearance by discharge phenomena on the voltage input type eliminator's ion generation bar of inflammable gas through an experimental tests. It was used Hydrogen, Ethylene, Propane, Methane gas with the inflammable gas and it was studied on the ignition phenomena by the length of ion-generation static bar, the number of ion-generation electrode and the variation of input voltage to the ion-generation electrode. As a result of this study it was confirmed that the shorter of the bar's length, the greater of explosion danger. And it is considered that there will not ignite at general using inflammable gas, in case of more than 900 mm bar and one electrode. 정전기 방전에 의하여 주위의 가연성 가스에 폭발을 일으킬 수 있는 가스관련시설, 석유화학공장, 화약 공장, 필름생산공장, 반도체 공장 등과 같은 가연성 가스를 주로 취급하는 장소에서는 정전기를 제거하기 위해 제전기를 사용하고 있다. 본 연구에서는 이들 장소에서 주로 사용되고 있는 전압인가식제전기(static eliminator)의 Bar에서 발생하는 방전에 의한 가연성 가스의 폭발현상을 고찰하였다. 가연성 가스는 수소, 에틸렌, 프로판, 메탄 가스 등을 사용하였으며, 제전기의 이온발생 Bar의 길이, 이온발생 전극의 수 및 이 온발생 전극에 인가되는 전압의 변화에 따른 점화 현상을 연구하였다. 연구결과 Bar의 길이가 짧을수록 폭발의 위험성이 증가됨을 확인할 수 있었으며 또한 900 mm 이상의 Bar에서 전극의 수가 1개인 경우 일반적으로 사용하는 가연성 가스에서는 점화가 되지 않음을 알 수 있었다.
이춘하,옥경재,김시국,지승욱 한국화재소방학회 2008 한국화재소방학회논문지 Vol.22 No.5
This experimental study showed the tracking characteristics of contaminated insulating materials of RCD. Electrolytes is made by IEC(International Electrotechnical Commission) 60589, NaCl added to deionized water as each 0.1 wt%. The used test equipment is application to KS(Korean Industrial Standard) C IEC 60112. The used samples is RCD(Residual Current Device) of tree companies. It is investigated carbonic electric conductive pass growth time and tracking growth form that contaminated insulators materials of RCD. As a result, carbonic electric conductive pass growth time and tracking growth form was different each companies. Track growth time of contaminated insulating materials was faster than non-contaminated. 본 논문은 국내에서 사용되고 있는 누전차단기 외함 절연재료의 오염에 의한 트래킹 특성을 연구하였다. IEC (International Electrotechnical Commission) 60589의 방법으로 만들어진 0.1wt% NaCl 용액을 이 용하여 KSC IEC 60112의 고체절연재료의 내트래킹 및 비교트래킹지수 측정 방법을 응용하여 실험을 하 였다. 실험에 사용된 시료는 3개 제조사의 누전차단기를 사용하였으며, 누전차단기의 절연재료가 오염되 었을 때 탄화도전로 발생시간 및 트래킹 발생형태를 분석하였다. 연구결과, 제조사별로 탄화도전로의 발생 시간 및 트래킹 발생형태가 상이하게 나타났다. 오염된 차단기의 절연재료의 트래킹 발생 시간이 정상시 료보다 빠르게 나타났다.
차하나,옥경재,김시국,이춘하,지승욱 한국화재소방학회 2008 한국화재소방학회논문지 Vol.22 No.4
This study has been conducted for the purpose of considering the problems expected when checking the smoke detector at site and how to improve the smoke detector. We have conducted this study focused on checking the problems expected upon site inspection and finding out the way of improving the site inspection by analyzing the reliability and performance of instrument used upon site inspection. The test results show that some problems exist in the reliability and performance of instrument used for the site inspection of smoke detector way of inspecting the inspection instrument. 본 연구는 우리나라 소화설비중 화재감지기 자체점검의 문제점 및 개선방안에 대하여 고찰하였다. 화재 감지기의 현장점검시 사용되고 있는 현장점검용 기기의 신뢰도 및 성능 분석을 통하여 현장점검의 문제점 을 파악하고 개선방안을 도출하는데 초점을 두었다. 분석결과 현장에서 사용되고 있는 화재감지기 현장점 검용 기기의 신뢰도 및 성능상에 문제와 점검방법상에 문제가 있는 것을 확인 할 수 있었다.