열화상 카메라를 이용한 건식벽체의 스틸스터드 형상에 따른 열성능 비교연구
장철용(Jang Cheol-Yong),엄은정(Um Eun-Jung),이나은(Lee Na-Eun) 한국태양에너지학회 2009 한국태양에너지학회 학술대회논문집 Vol.2009 No.11월
Dry wall using steel stud has the advantage of possibility to install various building, so it used to many buildings inside and outside of the country very rapidly. Though Light gauge steel framed housing offers many advantages to the consumer and the builder, the use of steel studs in wall system cause thermal problems such as thermal performance and pattern staing on walls. The present study has been conducted to observe effect of stud by the shape, and two kind of stud is made for this test to compare thermal performance. The test was conducted by setting those stud on the chamber and heating them. As the results of test and photograping by using TVS, there was temperature gap of each stud, and surface temperature of each section was appeared differently due to shape of stud delaying thermal bridge.
열화상 측정장비를 활용한 스틸스터드 형상에 따른 열성능 비교분석
장철용(Cheol-Yong Jang),엄은정(Eun-Jung Um),이나은(Na-Eun Lee) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
Dry wall using steel stud has the advantage of possibility to install various building, so it used to many buildings inside and outside of the country very rapidly. Though Light gauge steel framed housing offers many advantages to the consumer and the builder, the use of steel studs in wall system cause thermal problems such as thermal performance and pattern staing on walls. The present study has been conducted to observe effect of stud by the shape, and two kind of stud is made for this test to compare thermal performance. The test was conducted by setting those stud on the chamber and heating them. As the results of test and photograping by using TVS, there was temperature gap of each stud, and surface temperature of each section was appeared differently due to shape of stud delaying thermal bridge.
스틸 스터드 형상에 따른 건식벽체의 단열성능 비교 분석
장철용(Cheol-Yong Jang),이나은(Na-Eun Lee),엄은정(Eun-Jung Um) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
The dry wall using steel stud is used to buildings in the inside and outside of the country because it has the merit that application is possible to various architecture. The purpose of this study is to measure thermal performance of dry wall which uses steel stud transformed one by using measurement equipment to decrease heat bridge of steel stud and ensure heat performance as dry wall. As a comparative performance test result, dry wall which uses steel stud transformed one has a performance enhancement compare with the dry wall using general steel stud.
스틸 하우스 적용 스틸 스터드의 형상에 따른 단열성능 비교 연구
장철용(Jang Cheol-Yong),이나은(Lee Na-Eun),엄은정(Um Eun-Jung) 한국태양에너지학회 2009 한국태양에너지학회 학술대회논문집 Vol.2009 No.11월
The dry wall using steel stud is used to buildings in the inside and outside of the country because it has the merit that application is possible to various architecture. The purpose of this study is to measure thermal performance of dry wall which uses steel stud transformed one by using measurement equipment to decrease heat bridge of steel stud and ensure heat performance as dry wall. As a comparative performance test result, dry wall which uses steel stud transformed one has a performance enhancement compare with the dry wall using general steel stud.