환경변화에 따른 핀-관, PF 열교환기 적용 공조기 성능 특성 실험 연구
박경만(K.M. Park),엄유식(U.S. Um),권영철(Y.C. Kwon),이상재(S.J. Lee) 대한설비공학회 2009 대한설비공학회 학술발표대회논문집 Vol.2009 No.-
In the present study, performance characteristics on environment change of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP changing an outlet air velocity, an indoor/outdoor temperature and a relative humidity were obtained. Air-enthalpy calorimeter was used. As the air velocity, indoor temperature and relative humidity increase, capacity and COP increase. PF A/C has smaller refrigerant weight than the fin-tube A/C. The performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin.