안정적인 소화용수 공급을 위한 소방전술 개선에 관한 연구
장경남,안태회,박우진,백은선 한국화재소방학회 2022 한국화재소방학회논문지 Vol.36 No.5
The connected water pipe facility is an important fire extinguishing facility for supplying fire water to firefighters on thefire floor. However, there are cases where fire water is not supplied quickly, which is also caused by the inability to findthe connection water pipe inlet owing to unclear regulations on the installation location of the connection water pipe facilityfire safety standards. If the connected water pipe facility is not found, fire-fighting tactics involving ropes are used, whichtakes a lot of time. To improve this problem, we confirmed experimentally that fire extinguishing water can be quickly andstably delivered to fire suppression personnel using a water outlet (40 A) installed in an indoor fire extinguishing tank onthe first floor of an apartment. Through the experimental results, the Fire Safety Standards (NFSC 502) for Connected WaterPipeline Facilities (NFSC 502) proposed a plan to improve the fire safety standards (new) that require installation of wateroutlets (65 A, rotating) in the indoor firebox on the first floor of the apartment. If the revised fire safety standards are appliedto the new building, firefighters who arrive at the site can quickly and stably supply fire water through the connecting waterpipe connection port (65 A, rotary type) installed in the indoor fire extinguishing tank. 연결송수관설비는 소방관이 사용하는 소화활동설비로 화재층 진압대원에게 소화용수를 공급하는데 있어 중요한소방시설이다. 그러나 소화용수가 신속히 공급되지 못하는 경우가 발생하기도 하는데 이는 연결송수관설비 화재안전기준 송수구 설치 장소의 불명확한 규정으로 인해 연결송수관설비 송수구를 발견하지 못하는 경우가 원인이 되기도 한다. 연결송수관설비를 발견하지 못한 경우 로프를 활용한 소방전술을 활용하는데 이는 많은 시간이 소요되는단점이 있다. 이러한 문제점에 대한 개선방안으로 본 연구에서 아파트 1층 옥내소화전함 내에 설치된 방수구(40 A)를 송수구로 활용한 실험을 통해 화재층 진압대원에게 신속하고 안정적으로 소화용수를 송수할 수 있음을 확인하였다. 실험 결과를 통해 연결송수관설비 화재안전기준(NFSC 502) 규정에 ‘아파트 1층 옥내소화전함 내에 송수구(65 A,회전형)를 설치’토록 하는 화재안전기준 개정(신설) 개선방안을 제시하였다. 신축 되는 건물에 개정된 화재안전기준이 적용 된다면 현장에 도착한 소방대원은 소방차량에서 소방호스(65 A)를 전개하여 옥내소화전함 내에 설치된 연결송수관설비 연결송수구(65 A, 회전형)를 통해 신속하고 안정적으로 소화용수를 공급할 수 있을 것이다.
화재 현장 연결송수관설비 송수구 적극 활용 및 시간 단축에 관한 연구
장경남(Gyeong-Nam Jang),안태회(Tae-Hoi An),박우진(Woo-Jin Park),백은선(Eun-Sun Baek) 한국화재소방학회 2022 한국화재소방학회논문지 Vol.36 No.6
소화용수 공급을 위해 건물에 설치된 연결송수관설비 송수구를 빠른 시간 내에 위치를 확인할 수 있는 방안을 연구하였다. 화재층 진압대원에게 소방시설 송수구 설치 위치를 신속히 파악하지 못하여 소화용수 공급을 하지 못하거나 시간이 지연되는 문제에 대한 방안을 찾기 위함이다. 화재안전기술에서 정하는 소방시설 송수구 설치 위치에 대한 불명확한 규정으로 아파트 측면, 후면 등에 설치되어 일정한 장소에 소방시설 송수구가 설치되지 않고 있다. 이러한 이유로 화재 현장에서 소방대원이 소방시설 송수구 위치를 빠른 시간 내에 발견하지 못하게 되고, 결국 소화용수를 공급하는 데 시간이 지연되는 문제가 발생하고 있다. 이러한 문제를 해결하기 위해서는 「소방시설 설치 안내표지」를 아파트 1층 옥내소화전 함 내에 부착토록 하여야 한다. 그리고 소방시설 설치 안내 표지를 옥내소화전함 내 설치토록 화재안전기준에 명문화하여야 한다. 이는 화재 현장에서 소방시설 송수구 위치를 발견하기 어려운 문제와 시간 지연의 문제에 대한 방안이 될 것이다. 무엇보다 화재층 진압대원에게 빠른 시간 내에 소화용수가 공급될 수 있을 것이다. This study examined a method of confirming the location of connection water pipe facilities installed in buildings in a short time. The study aimed to help solve failure to supply firefighters with fire extinguishing water or delays because the location of the fire extinguishing facility’s water supply could not be timely identified. Owing to unclear regulations on the location of the fire-fighting facility’s water outlet installation as prescribed by the Fire Safety Technology, many apartments install it on the side or back of buildings. Given that the fire-fighting facility’s water outlet is not installed in a certain place, firefighters cannot quickly find the location of the fire facility’s water outlet at fire sites, leading to delays in securing fire extinguishing water. A solution is to attach “firefighting facility installation guide signs” to the indoor fire extinguishing tank on the first floor of apartment buildings. Additionally, the fire safety standards shall be stipulated on the installment of indoor signs indicating the fire-fighting facilities. These solutions can address difficulties in finding fire facility’s water outlet at the fire site and resolve delays. Above all, implementing these can ensure the timely supply of fire extinguishing water to firefighters.
이온교환 칼럼 크로마토그래피를 이용한 난백에서 Lysozyme의 연속추출
박성준,김현석,김현위,안태회,박기문,최춘언,Park, Seong-Joon,Kim, Hyeon-Seok,Kim, Hyean-Wee,Ahn, Tae-Hoe,Park, Ki-Moon,Choi, Chun-Un 한국식품과학회 1990 한국식품과학회지 Vol.22 No.6
식품 및 의약품 원료로 이용되고 있는 Iysozyme을 난백으로부터 이온교환 크로마토그래프를 이용하여 연속추출하였다. 사용된 수지는 지금까지 수율, 순도, 작동용이성에서 가장 효과적이라고 밝혀져 있는 Duolite C-464 양이온교환수지를 선택하여 $Na^+$형으로 $pH\;7.9{\pm}0.1$로 평형화하여 사용하였다. 조제용 자동 Liquid Chromatography(LC) system(column size ; i.d. 50 mm, bed volumn ; 1020 ml)에서 수지 평형화, 난백접촉, rinse, lysozyme용출 순으로 cycle을 연속적으로 반복하면서 시행하고 그 재현성을 관찰하기 위해 각 cycle별 rinse끝점과 용출끝점의 UV level을 비교하였다. 그 결과 rinse끝점은 19 cycle까지 30% 이하를 유지하였다. 용출 끝점은 17 cycle까지는 30% 이하에서 비교적 안정하였으나 18 cycle 이후 부터는 50% 이상으로 용출능력이 현저하게 감소하였다. 또한, 회수율 비교에서 17cycle까지는 90% 이상을 유지하다가 18cycle에서는 72%, 19 cycle에서는 65%로 격감하였다. 본 추출 정제 lysozyme은 전기영동상 단일 band로 나타났고, densitometer로 측정한 순도는 99% 이상이었다. Continuous column chromatographic separation of lysozyme from egg white was investigated. A weak acid type cation exchange resin, Duolite C-464, was used because of high lysozyme recovery and ease of column operation in this experiment. The resin was equilibrated at $pH\;7.9{\pm}0.1$ in Na+form. Continuous lysozyme separation was processed by repeating cycles(one cycle : resin equilibration, flow egg white, rinse, lysozyme elution) in automated preparative Liquid Chromatography(LC) system(column size ; i.d. 50 mm, resin bed volumn ; 1020 ml). At comparison of UV levels in rinse end point and elution end point of every cycle, the UV levels of rinse end point are maintained below 30% for 19 cycles and that of elution end point are also maintained below 30% for 17 cycles, stably, but was increased above 50% after 18 cycle. That indicated the eluting ability of lysozyme was reduced conspicuously after 18 cycle in continuous cycling process. The recovery of lysozyme was maintained above 90% from one to 17 cycle, but was decreased to 72% and 65% in 18 cycle and 19 cycle, respectively.