스마트시티 유스케이스에 따른 스마트도로조명 요구 특성에 대한 분석
강정모(Jeungmo Kang),양명식(Myungsik Yang),신상욱(Sangwook Shin),석대일(Daeil Seok),장우진(Woojin Jang) 한국조명·전기설비학회 2021 한국조명·전기설비학회 학술대회논문집 Vol.2021 No.11
Recently, major countries are promoting carbon neutrality policies to prevent climate change. In particular, street lighting accounts for 40-50% of city-related power consumption, drawing keen attention to energy savings through smart street lighting. In addition, R&D and demonstration of smart street lighting based on various use cases are being promoted because new smart city-linked services can be developed using this infrastructure. This paper aims to provide the analysis results for the performance requirements of smart street lighting based on these various smart city linkage use cases.
초고층 건축물 수직조닝별 연돌효과의 원인 및 해결 방안 분석
신상욱 ( Shin¸ Sang Wook ),류종우 ( Ryu¸ Jong Woo ),정희웅 ( Jeong¸ Hee Woong ),김대영 ( Kim¸ Dae Young ) 한국건축시공학회 2021 한국건축시공학회지 Vol.21 No.5
도시 인구의 과밀화로 고층 건물에 대한 폭발적인 수요와 공급이 발생하였다. 고층 빌딩은 각 도시의 구심점으로 도시 이미지를 제고하는데 기여하고 있으나 연돌효과로 인해 승강기 문의 오작동, 외벽의 문과 창문 개폐의 어려움, 상층부로 확산하는 연기와 악취, 소음, 에너지 손실, 화재 및 오염물질의 급속한 확산 등 예기치 못한 다양한 문제를 야기하고 있다. 본 연구에서는 초고층 건축물을 수직조닝별로 구분하여 연돌효과의 원인과 해결방안을 분석하고 설계와 시공 방안으로 도출하였다. 외기를 차단하는 초기 계획과 정밀한 시공을 통한 기밀성 확보를 통해 저층부에서 유입되는 기류를 능동적으로 차단하여 건물의 내ㆍ외부 기밀성을 확보하는 방안을 모색하였다. 설비적 해결대책은 연돌효과로 인한 특정 현상을 줄이기 위한 대책이 될 수 있으나 이에 따른 2차 피해의 가능성이 높기 때문에 최소한으로 적용해야 한다. 따라서 본 연구는 연돌효과의 원인과 대책방안을 수직 조닝별로 설계적, 시공적 대책을 제시함으로써 체계적인 연돌효과 관리의 필요성을 역설하였다. 또한 본 연구가 설계 및 시공뿐만 아니라 건물 유지관리에도 도움이 되기를 기대한다. Urban overcrowding has created an explosive supply and demand for high-rise buildings. High-rise buildings are contributing to enhancing the image of the city by serving as focal points, but due to the stack effect, malfunction of elevator doors, difficulties in opening and closing the doors and windows of the outer wall, smoke and odors spreading to the upper floors, noise, energy loss, fire and pollutants have been causing various unexpected problems such as rapid spread of fire. This study classified high-rise buildings according to their vertical zoning, analyzed the causes of and solutions to the stack effect, and derived design and construction methods. Through the initial plan to block the outside air and securing airtightness through precise construction, we sought ways to secure the airtightness inside and outside the building by actively blocking the airflow from the lower floors. In addition, the facility solution can be a measure to reduce the specific phenomena caused by the stack effect, but it should only be applied to the minimum extent because the potential for secondary damage is high. This study emphasized the need for systematic stack effect management by suggesting design and construction measures for each vertical zoning of the causes and countermeasures of the stack effect. It is expected that this study will be helpful not only for design and construction, but also for building maintenance.