노경수,최준호,Ro, Kyoung-Soo,Choi, Joon-Ho The Korean Institute of IIIuminating and Electrica 2007 조명·전기설비학회논문지 Vol.21 No.1
This paper presents a pitch angle controller of a grid-connected wind turbine system for extracting maximum power from wind and implements a modeling and simulation of the wind turbine system on MATLAB/Simulink. It discusses the maximum power control algorithm for the wind turbine and presents, in a graphical form, the relationship of wind turbine output, rotor speed, and power coefficient with wind speed when the wind turbine is operated under the maximum power control algorithm. The objective of pitch angle control is to extract maximum power from wind and is achieved by regulating the blade pitch angle during above-rated wind speeds in order to bypass excessive energy in the wind. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction during above-rated wind speeds and effectiveness of the proposed controller would be satisfactory.
노경수,최준호,Ro, Kyoung-Soo,Choi, Joon-Ho The Korean Institute of IIIuminating and Electrica 2006 조명·전기설비학회논문지 Vol.20 No.5
전력산업이 수직독점적인 구조에서 규제완화의 경쟁체제로 전환됨에 따라 무효전력서비스의 요금산정이 전력시장 운영자에게는 새로운 이슈가 되고 있다. 본 논문은 몇몇의 선진국과 국내에서 채용되는 무효전력서비스에 대한 요금산정방법을 검토하고, 무효전력시장을 이용하는 새로운 요금산정방법을 제안한다. 무효전력시장은 무효전력 발전원이 제시하는 입찰값을 바탕으로 하루전 전력시장 후에 무효전력 최적조류계산을 거쳐 단일가격으로 결정된다. 제안하는 방법은 무효전력 설치용량에 대한 투자비뿐만 아니라 무효전력 생산량을 늘리기 위해 발전기가 줄이게 되는 유효전력에 대한 기회비용을 함께 고려하고 있다. 26모선 모델계통에서의 사례연구를 통하여 제안하는 방법의 효용성을 입증하고 있다. As electric power systems have been moving from a vertically integrated structure to a deregulated environment, calculating reactive power service charges is a new challenging theme for market operators. This paper examines various methods for reactive power management adopted in some deregulated foreign and domestic markets and then proposes a new method to calculate reactive power service charges using a reactive power market. The reactive power market is operated based on bids from the generating sources and is settled on uniform prices by running reactive OPF programs after the day-ahead electricity market. The proposed method takes into account recovering not only the costs of installed capacity but also the lost opportunity costs incurred by reducing active power output to increase reactive power production. A numerical sample study is carried out to illustrate the processes and appropriateness of the proposed method.
노경수,Ro, Kyoung-soo The Korean Institute of IIIuminating and Electrica 2004 조명·전기설비학회논문지 Vol.18 No.6
본 논문은 전력산업이 경쟁체제로 전환되어 전력시장으로 운영될 경우 보조서비스의 하나인 유효전력손실 배분에 관한 것으로 손실배분계수를 이용하여 유효전력 손실을 부하에 배분하는 방법을 제안하며 아울러 제안하는 방법을 한계손실계수를 이용하는 방법과 비교하고자 한다. 제안하는 방법은 먼저 손실배분계수를 정의하며 이것을 이용하여 유효전력 손실에 대한 각 부하의 분담분을 계산한다. 9-모선 샘플시스템에 대한 사례연구를 통하여 제안하는 알고리즘의 효용성을 입증하고 있으며 한계손실계수를 이용하는 것보다 손실배분계수를 이용하여 유효전력손실을 부하에 배분하는 것이 타당하다는 주장을 담고 있다. The paper proposes a method calculate the allocations of real power losses in transmission lines to individual loads based on loss distribution factors and compares them with those using marginal loss factors. The proposed method is implemented by defining loss distribution factors and analysing the individual loads' shares in the transmission line losses. Computer simulations on a 9-bus sample system verify effectiveness of the algorithm proposed and give an assertion that it is desirable to allocate power losses to loads using loss distribution factors rather than based on marginal loss factors.
계통연계 풍력발전시스템의 무효전력 보상에 대한 시뮬레이션
노경수(Kyoung-Soo Ro),장보경(Bo-Kyoung Jang) 한국조명·전기설비학회 2011 조명·전기설비학회논문지 Vol.25 No.6
Reactive power support is considered to be necessary for dealing with a voltage stability issue with wind turbine system employing squirrel-cage induction generator(SCIG). This paper analyses steady-state characteristics of the SCIG wind turbine system by simulating torque-slip characteristics of SCIG with respect to variations of interconnecting network strength and generator terminal voltage. It also presents dynamics analysis of SCIG wind turbine system on Simulink to investigate the impact of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient stability enhancement. It analysed transient stability with varying fault duration times and compared the transient stability characteristics with varying rated capacities of SVC and STATCOM. It is shown that the STATCOM has a better performance and reactive power support compared to SVC.
이중여자 유도발전기를 이용한 가변속운전과 정속운전 풍력발전시스템의 운전특성 비교
노경수(Kyoung-Soo Ro),김태호(Tae-Ho Kim) 대한전기학회 2009 전기학회논문지 Vol.58 No.7
This paper analyzes the steady-state operating characteristics of doubly-fed induction generator(DFIG) and fixed-speed induction generator(FSIG) in wind turbine system. It also presents a modeling and simulation of a grid-connected wind turbine generation system for dynamics analysis on MATLAB/Simulink, and compares the responses between DFIG and FSIG wind turbine systems with respect to wind speed variation, 3-phase fault and 1-phase ground fault of the network. Simulation results show the variations of generator's active/reactive output, rotor speed, terminal voltage, fault current, etc. Case studies demonstrate that DFIG illustrates better performance compared to FSIG.
Kyoung-Soo Ro(노경수),Joon-Ho Choi(최준호) 한국조명·전기설비학회 2007 조명·전기설비학회논문지 Vol.21 No.1
This paper presents a pitch angle controller of a grid-connected wind turbine system for extracting maximum power from wind and implements a modeling and simulation of the wind turbine system on MATLAB/Simulink. It discusses the maximum power control algorithm for the wind turbine and presents, in a graphical form, the relationship of wind turbine output, rotor speed, and power coefficient with wind speed when the wind turbine is operated under the maximum power control algorithm. The objective of pitch angle control is to extract maximum power from wind and is achieved by regulating the blade pitch angle during above-rated wind speeds in order to bypass excessive energy in the wind. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction during above-rated wind speeds and effectiveness of the proposed controller would be satisfactory.