http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
초고층 오프셋 아웃리거 구조시스템의 최적 아웃리거 위치에 대한 탐색
김형기,Kim, Hyong-Kee 한국구조물진단유지관리공학회 2017 한국구조물진단유지관리공학회 논문집 Vol.21 No.6
The purpose of this paper is to search the optimal location of offset outrigger system in high-rise building after a structural schematic design of 80 stories building was conducted, making use of MIDAS-Gen. In this research, the key factors of analysis study were column stiffness, outrigger position in plan and outrigger location in height. For the aim of finding out the optimum position of offset outrigger system in tall building, we studied the lateral displacement in top floor which is the very essential variables in the structural design of high-rise building. The results of study showed that the column stiffness, the outrigger location in plan and outrigger location in height had an effect on the optimal position of outrigger system. Also, it is indicated that the research results can be useful in acquiring the structural design materials for seeking the optimum position of offset outrigger system in tall building. 본 논문은 오프셋 아웃리거의 최적위치를 알기 위하여 우선 아웃리거 구조시스템이 설치된 80층의 초고층건물을 대상으로 MIDAS-Gen을 이용하여 계획설계 수준의 구조설계를 실시하였다. 그리고 본 연구에서는 기둥의 강성, 아웃리거의 평면상 위치, 아웃리거의 설치 높이 등을 주요한 변수로 선택하여 구조해석을 진행하였다. 또한 초고층건물의 오프셋 아웃리거에 대한 최적위치를 찾는 것을 목적으로 초고층건물의 구조설계에서 가장 필수적인 최상층에서 발생하는 수평변위를 분석하였다. 본 연구의 결과, 기둥의 강성, 아웃리거의 평면상 위치, 아웃리거의 설치 높이는 아웃리거 구조시스템의 최적위치에 영향을 주는 것으로 나타났다. 또한 본 연구의 결과는 초고층건물의 오프셋 아웃리거 구조시스템의 최적위치를 알려주는 구조설계 자료로 유용하다고 사료된다.
고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥$\cdot$슬래브 접합부 구조성능
김형기,Kim, Hyong-Kee 한국구조물진단학회 2006 한국구조물진단유지관리공학회지 Vol.10 No.1
플랫 플레이트 구조에서 고강도 콘크리트를 사용함에 따라서 접합부의 전단강도와 같은 구조성능을 향상시켜서 플랜 플레이트 구조의 단점을 보완하여 장점을 극대화시킬 수 있다고 판단된다. 이에 본 논문에서는 70MPa급 고강도 콘크리트를 사용한 플랫 플레이트 구조의 기둥 슬래브 접합부 실험체를 제작한 후에 수직하중과 수평하중의 조합하중을 가력하여 플랫 플레이트 구조의 기둥·슬래브 접합부에 대한 전단강도를 비롯한 주요한 구조성능을 평가하고자 한다 본 연구에서의 실험변수는 슬래브의 철근비와 슬래브에 작용하는 수직하중의 비율로 하였다. The reinforced concrete flat plate system provides architectural flexibility, clear space, reduced building height, simple formwork, which consequently enhance constructibility. One of the serious problem in the flat plate system is brittle punching shear failure due to transfer of shear force and unbalanced moments in column-slab connection. Since the use of high strength concrete recently kas become in practice for reinforced concrete structures. it is highly desired to establish the structural design method for flat Plate construction using high strength concrete In this paper, interior column-slab connection constructed with high strength concrete were tested under lateral and gravity loads to evaluate their strength and behavior. The test parameters were slab reinforcement ratio and the gravity load levels.
코어 및 오프셋 아웃리거 구조시스템의 수평거동에 대한 분석
김형기 ( Hyong-kee Kim ) 한국구조물진단유지관리공학회 2021 한국구조물진단유지관리공학회 논문집 Vol.25 No.4
본 연구에서는 코어 및 오프셋 아웃리거 구조의 수평거동을 파악할 목적으로 70층 규모의 초고층 아웃리거 건물을 대상으로 MIDAS-Gen을 이용하여 구조해석 및 구조설계를 실시하였다. 그리고 본 해석의 주요한 변수는 아웃리거의 강성과 아웃리거의 평면상 위치로 설정하였다. 또한 본 해석결과에 근거하여 코어 및 오프셋 아웃리거 구조의 슬래브, 아웃리거, 외곽 기둥과 같은 구조요소들의 수평거동을 분석하였다. 본 해석연구의 결과에서는 아웃리거의 강성과 아웃리거의 평면상 위치가 초고층 아웃리거 구조시스템의 수평거동에 어떤 영향을 주는지를 분석하여 나타내었다. 특히 코어 아웃리거 구조에서는 전단벽과 외곽기둥을 연결하는 아웃리거가 위치하는 슬래브에 응력이 크게 작용하였고, 오프셋 아웃리거 구조에서는 전단벽과 아웃리거 사이에 위치한 슬래브에 응력이 크게 작용하였다. 또한 본 연구결과는 초고층 아웃리거 구조시스템의 합리적인 구조설계에 필요한 공학 데이터를 얻는데 중요한 도움이 된다고 사료된다. The research intended to understand the lateral behavior in core and offset outrigger system. To achieve this goal, a structural analysis and design of 70 stories building was carried out by making use of MIDAS-Gen. And the primary parameters of this analysis were the stiffness of outrigger and the location of outrigger in plan. On the basis of the analysis results, we analyzed the lateral behavior of structural elements such as slab, outrigger and exterior columns in core and offset outrigger. In this analysis research, it is indicated that the stiffness of outrigger and the outrigger location in plan had an any impact on lateral behavior in outrigger system of tall building. Specially, slab stresses in core outrigger system were highly distributed in the slab near the outrigger system to connect shear walls and exterior columns while slab stresses in offset outrigger system were highly distributed in the slab between the outrigger system and shear walls. Also the study results can be of significant help to obtaining the engineering data for the reasonable structure design of the high-rise outrigger system.
아웃리거 강성을 고려한 비렌딜 아웃리거 구조시스템의 최적 위치
김형기(Kim, Hyong-Kee) 대한건축학회 2021 대한건축학회논문집 Vol.37 No.7
This research aimed to propose the optimal position of vierendeel outrigger. To achieve the study purpose, a structural design of 60 stories building was carried out, making use of the structural analysis program MIDAS-Gen. And the main parameters of this analysis research were the stiffness of outrigger, the outrigger types such as general outrigger and vierendeel outrigger, the stiffness of vertical members in vierendeel outrigger and the outrigger location in height. Based on the results of this analysis, we studied the lateral displacement in top floor, the influences of the main analysis parameters on the optimal position of vierendeel outrigger, and so on. The paper proposed the equation to predict the optimum location of vierendeel outrigger system reflecting the effect of shear deformation in vierendeel outrigger. Also, the study results can provide a great help in getting the structural design data of the optimal vierendeel outrigger position in high-rise building.
두개의 아웃리거가 설치된 초고층건물에서 최적 아웃리거 구조 위치에 대한 탐색
김형기(Kim, Hyong-Kee) 대한건축학회 2014 大韓建築學會論文集 : 構造系 Vol.30 No.6
This research aimed to grasp the optimal location for two-outrigger system in high-rise building by using MIDAS-Gen. In this study, the main variables of structural analysis research were the outrigger location, the outrigger spacing and the stiffness of primary structural members such as outrigger systems, exterior columns connected in outrigger system, shear walls and frames. For the purpose of investigating the optimal position for two-outrigger system in tall building, we compared and examined the lateral displacement in top floor of 80 stories high-rise building. In the results of this analysis research, it is showed that the outrigger location, the outrigger spacing and the stiffness of primary structural members such as outrigger systems, exterior columns connected in outrigger system and shear wall had an impact on the optimal location of two-outrigger system. Furthermore, it is indicated that the study results can provide assistance in getting the structural design data for searching the optimal location of two-outrigger system in tall building.