화력 발전소에 설치한 유도발전기의 계통 연계시 돌입전류에 의한 전압강하 저감
김일중(Il-Jung Kim),김종겸(Jong-Gyeum Kim) 한국신재생에너지학회 2018 신재생에너지 Vol.14 No.1
Squirrel cage induction generators are frequently applied to small to medium-sized hydro power plants, because of their simple and rugged structure, low construction cost and easy maintenance. Therefore, it is expected that induction generators will be used more and more in hydroelectric power generation in the future. The biggest problem in the application of induction generators is the large inrush current at the grid connection. This inrush current is large enough to equal the current flowing at the start of the motor, causing a voltage drop in the connected distribution system. Therefore, the range of voltage fluctuation is specified differently according to the generator output. This paper is the result of a study on the capacity range of induction generators that does not exceed the allowable range of voltage drop in the distribution line.
전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석
김일중(Il-Jung Kim),김종겸(Jong-Gyeum Kim),박영진(Young-Jeen Park),김성헌(Sung-Hun-Kim) 대한전기학회 2010 전기학회논문지 P Vol.59 No.3
Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.
김일중(Il-Jung Kim),김종겸(Jong-Gyeum Kim) 한국조명·전기설비학회 2009 조명·전기설비학회논문지 Vol.23 No.2
전력용 커패시터는 유도성 부하의 낮은 역률을 보상하기 위해 설치하는 경우가 많지만, 전력변환장치에서 발생하는 고조파를 줄이기 위해 수동형 필터로서 리액터와 함께 사용되는 경우도 있다. 수동형 필터는 커패시터와 리액터를 직렬로 연결하여 사용한다. 필터는 비선형 부하에서 발생하는 고조파를 흡수하는 역할을 하기 때문에 전압 및 전류 스트레스를 받아 소손 또는 열화되어 정상적인 수명을 보장받지 못하는 경우가 많다. 본 논문에서는 PWM 인버터의 전원측에 설치된 수동형 필터가 고조파를 저감할 때 받는 영향을 해석하였다. Power capacitor is generally installed to compensate for the low power factor of inductive load But it has been used as passive filter to reduce harmonics generated by the power conversion device. Passive filter is composed by the series connection of reactor and capacitor. Because passive filter has play an important role on the absorber of harmonics, it takes voltage and current stress, follows partially burned on flamed and degradation, finally it has not guaranteed normal life. In this paper, we analyzed the effect that passive filter installed at the source side of PWM inverter is received by harmonics absorption.
金一中(Il-Jung Kim),金宗謙(Jong-Gyeum Kim) 대한전기학회 2008 전기학회논문지 P Vol.57 No.1
Most of the low-voltage feeder are designed with approximately balanced and connected at the three phase four wire systems. However, Most of the power distribution systems' load which is composed of single or three phase are unbalanced by generating load unbalance. Unbalanced current will draw a highly unbalanced voltage. The power factor of an induction motor at rated operation is between 25 and 90%, depending on the size and speed of the motor. However, many induction motors operate below the nominal rating, resulting in poor power factor. This condition needs power factor improvement. Addition of power capacitor at the motor terminal may draw to stress due to voltage unbalance. This paper presents operation characteristics on steady states of a three-phase induction motor under unbalanced voltages with power capacitor. The existence of voltage unbalance have an effect on stress of power capacitor
전압 불평형하에서 콘덴서와 리액터의 직렬 연결 사용시의 콘덴서의 전압 및 전력
김종겸(Jong-Gyeum Kim),박영진(Young-Jeen Park),김일중(Il-Jung Kim),김성헌(Sung-Hun Kim) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.4
콘덴서는 부하에 필요한 무효전력을 보상하기 위해 사용하지만, 고조파를 저감하기 위해 리액터와 함께 사용하는 경우도 있다. 콘덴서에 리액터의 추가는 전압상승을 초래한다. 본 연구에서는 전압 불평형시 콘덴서에 리액터를 추가할 경우 발생하는 전압 및 전력특성의 변화를 계산과 측정을 통해 규정에 제시한 범위 여부를 확인하였다.
김종겸(Jong-Gyeum Kim),박영진(Young-Jeen Park),김일중(Il-Jung Kim),김성헌(Sung-Hyun Kim),이동주(Dong-Ju Lee),이경배(Kyung-Bae Lee) 대한전기학회 2010 대한전기학회 학술대회 논문집 Vol.2010 No.7
고조파 저감 및 역률 보상용으로 사용되는 리액터가 고장이 자주 발생하고 있다. 필터로서 사용되는 콘덴서에 대해서는 전압, 전류 및 전력 허용범위가 잘 규정되어 있지만 리액터에 대해서는 전압 및 전류 특성에 대해 구체적인 범위를 정하지 않고 있다. 본 연구에서는 콘덴서와 직렬로 연결하여 사용하는 리액터에 대해 전압 및 전류 특성을 해석하여 스트레스를 받는 정도를 분석하고 허용범위에 대한 기술적인 사항을 제시하고자 한다.