폴리에틸렌 배관 전기융착부 단기성능 평가를 위한 융합물량 영향 평가
길성희,권정락,조지환,Kil, Seong-Hee,Kwon, Jeong-Rock,Jo, Ji-Hwan 한국에너지학회 2005 에너지공학 Vol.14 No.2
본 연구에서는 폴리에틸렌 배관 전기융착부 단기성능 평가를 위한 비파괴검사를 실시할 경우 발견되는 결함에 대한 판정기준을 개발하였다. 인위적으로 $3.8mm\~25mm$ 내에서 6가지 크기의 결함을 삽입한 시험 편을 설계 및 제작하여 기계적 평가를 실시하고 또 이론적 해석을 하였다. 안전계수 2를 적용하여 유효 응력을 산정할 경우 최대 허용 가능한 결함 크기는 11 mm(열선 폭의 $30\%$)이며 안전 계수를 4를 적용할 경우에 최대 허용 가능한 결함 크기는 3.8mm(열선 폭의 $10\%$)이다. In order to investigate the short-term performance of polyethylene electrofusion joints, the mechanical tests and stress analysis have been conducted to the artificially defected weld joints. The defects of lack of fusion with a square-type were fabricated with 10, 20, 30, 40, 50, 60$\%$ size of the width of heat-ing wire zone, respectively. In this defect sires range, both tensile and bending test results showed the dependence of defect size to the electrofusion joints performance, but both sustained pressure and crush test results didn't. The numerical stress analysis results including the soil and internal pressures, tensile and bend-ing stresses clearly showed the dependence of fusion defect size. Based on both mechanical test and stress analysis results, the maximum acceptable defect size in polyethylene electrofusion joints is discussed.
Seong-Hee Kil(길성희),Byung-Duk Kim(김병덕),Jeong-Rock Kwon(권정락),Kee-Bong Yoon(윤기봉) 한국가스학회 2013 한국가스학회지 Vol.17 No.5
열가소성 플라스틱배관의 전기융착부에 대한 비파괴검사방법은 융착부의 안전성을 확보하고 장기적인 신뢰성을 확보하기 위한 방법이다. 정상적인 방법에 의하여 융착된 접합부에서도 배관의 진원도와 전기융착 소켓과의 진원도 차이 또는 기공 등에 의해 융착부에 결함이 발생할 수 있다. 본 연구에서는 위상배열초음파를 이용하여 손상된 폴리에틸렌 전기융착부의 검사를 수행하였다. 검사 대상인 250mm 직경의 폴리에틸렌 배관 전기융착부는 1994년 12월에 융착되었으며 실제 작동 압력은 2.45kPa이다. 2004년 2월 소켓 이음부 근처에서 가스가 누설되어 수거되었다. 손상된 전기융착부에 대하여 첫 번째로 육안검사를 실시하고 다음에 위상배열초음파를 이용한 비파괴검사를 실시하였다. 그리고 절단 검사를 실시하여 각각의 검사 결과와 비교하였으며 위상배열 초음파를 이용한 검사결과와 절단 검사 결과가 동일함을 확인하였다. Non destructive testing(NDT) methods of electrofusion(EF) joints of thermoplastics pipes are required for fusion joint safety and for the long term reliability of a pipe system. Electrofusion joints, which are joined at the proper fusion process and procedures, may encounter defects due to the difference of ovality between pipes and coupling, improper fusion process or porosity result from electrofusion joining. These defects can cause the failure of pipeline and by extension, they can be caused the limit to expand the use of plastics pipes. This paper studies inspection results using ultrasonic imaging method for damaged polyethylene electrofusion joints. Gas was leaking from 250mm diameter polyethylene electrofusion joints at February 2004 which was electrofused at December 1994 and operation pressure was 2.45kPa. First, surface inspection was conducted and then in order to find the types of defects examination using ultrasonic imaging method was performed. Lack of fusion and inappropriate inserting for polyethylene pipes into electrofusion coupling were found and causes of the gas leak were judged that misalignment and insert defect. Cutting inspection was performed and each inspection results were compared to. Results of ultrasonic imaging method and cutting inspection were the same.
길성희(Seong Hee Kil),박교식(Kyo Shik Park),김지윤(Ji Yoon Kim) 한국에너지학회 2008 한국에너지공학회 학술발표회 Vol.2008 No.-
도시가스용 배관으로 사용하고 있는 폴리에틸렌 배관은 유연하여 시공이 용이할 뿐만 아니라 부식 및 전식이 일어나지 않아 유지관리가 편리하고 교체 없이 50년 이상 사용이 가능하여 금속 소재에 비하여 경제적이기 때문에 그 사용량이 증가하고 있다. 그러나 차량의 증가 등으로 인하여 매설된 배관에 많은 응력이 집중되고 있다. 따라서 토하중 뿐만 아니라 증가한 차량 등에 의한 하중이 복합적으로 작용할 경우에 매설된 배관이 어느 정도의 응력을 받고 있는지를 검토하고자 하였다. 직경이 50~400㎜인 배관을 대상으로 매설깊이를 0.6~1.2m로 변화시키고 사용압력을 0.4~4bar로 변화시켜 그 결과를 검토하였다. 결과는 수식해와 유한요소 해석 방법을 이용하여 계산하였으며 두 결과를 비교하여 유한요소 해석 방법의 신뢰성을 높였다. 두 해석방법 모두 내압에 의한 영향, 토양하중에 의한 영향 그리고 차량 하중에 의한 영향을 각각 계산하였다. 그리고 각 하중이 복합적으로 작용할 경우에 대한 응력을 계산하여 매설 깊이에 따라 배관에 발생하는 응력을 계산하였다. 또한 가스배관 설계에 사용하는 허용응력을 4가지로 구분하여 발생한 응력과 비교하여 그 안전성을 검토하였다. 수식해와 유한요소 해석 결과를 비교하여 각각의 결과를 검증한 결과 수식해가 유한요소 결과보다 약간 높은 응력값을 나타내었으며 내압, 토하중, 차량하중 등이 복합적으로 작용할 경우에 매설깊이가 1m일 때 가장 낮은 원주방향응력이 발생하였다.